ITU-T H 831-2015 Conformance of ITU-T H 810 personal health devices WAN interface Part 1 Web services interoperability Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性 广域网(WAN)接口部分1 .pdf

上传人:inwarn120 文档编号:797938 上传时间:2019-02-02 格式:PDF 页数:36 大小:638.86KB
下载 相关 举报
ITU-T H 831-2015 Conformance of ITU-T H 810 personal health devices WAN interface Part 1 Web services interoperability Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性 广域网(WAN)接口部分1 .pdf_第1页
第1页 / 共36页
ITU-T H 831-2015 Conformance of ITU-T H 810 personal health devices WAN interface Part 1 Web services interoperability Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性 广域网(WAN)接口部分1 .pdf_第2页
第2页 / 共36页
ITU-T H 831-2015 Conformance of ITU-T H 810 personal health devices WAN interface Part 1 Web services interoperability Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性 广域网(WAN)接口部分1 .pdf_第3页
第3页 / 共36页
ITU-T H 831-2015 Conformance of ITU-T H 810 personal health devices WAN interface Part 1 Web services interoperability Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性 广域网(WAN)接口部分1 .pdf_第4页
第4页 / 共36页
ITU-T H 831-2015 Conformance of ITU-T H 810 personal health devices WAN interface Part 1 Web services interoperability Sender (Study Group 16)《ITU-T H 810的个人健康设备的一致性 广域网(WAN)接口部分1 .pdf_第5页
第5页 / 共36页
点击查看更多>>
资源描述

1、 005_ I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T H.831 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (01/2015) SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS E-health multimedia services and applications Interoperability compliance testing of personal health systems

2、(HRN, PAN, LAN, TAN and WAN) Conformance of ITU-T H.810 personal health devices: WAN interface Part 1: Web services interoperability: Sender Recommendation ITU-T H.831 ITU-T H-SERIES RECOMMENDATIONS AUDIOVISUAL AND MULTIMEDIA SYSTEMS CHARACTERISTICS OF VISUAL TELEPHONE SYSTEMS H.100H.199 INFRASTRUCT

3、URE OF AUDIOVISUAL SERVICES General H.200H.219 Transmission multiplexing and synchronization H.220H.229 Systems aspects H.230H.239 Communication procedures H.240H.259 Coding of moving video H.260H.279 Related systems aspects H.280H.299 Systems and terminal equipment for audiovisual services H.300H.3

4、49 Directory services architecture for audiovisual and multimedia services H.350H.359 Quality of service architecture for audiovisual and multimedia services H.360H.369 Telepresence H.420H.429 Supplementary services for multimedia H.450H.499 MOBILITY AND COLLABORATION PROCEDURES Overview of Mobility

5、 and Collaboration, definitions, protocols and procedures H.500H.509 Mobility for H-Series multimedia systems and services H.510H.519 Mobile multimedia collaboration applications and services H.520H.529 Security for mobile multimedia systems and services H.530H.539 Security for mobile multimedia col

6、laboration applications and services H.540H.549 Mobility interworking procedures H.550H.559 Mobile multimedia collaboration inter-working procedures H.560H.569 BROADBAND, TRIPLE-PLAY AND ADVANCED MULTIMEDIA SERVICES Broadband multimedia services over VDSL H.610H.619 Advanced multimedia services and

7、applications H.620H.629 Ubiquitous sensor network applications and Internet of Things H.640H.649 IPTV MULTIMEDIA SERVICES AND APPLICATIONS FOR IPTV General aspects H.700H.719 IPTV terminal devices H.720H.729 IPTV middleware H.730H.739 IPTV application event handling H.740H.749 IPTV metadata H.750H.7

8、59 IPTV multimedia application frameworks H.760H.769 IPTV service discovery up to consumption H.770H.779 Digital Signage H.780H.789 E-HEALTH MULTIMEDIA SERVICES AND APPLICATIONS Interoperability compliance testing of personal health systems (HRN, PAN, LAN, TAN and WAN) H.820H.859 Multimedia e-health

9、 data exchange services H.860H.869 For further details, please refer to the list of ITU-T Recommendations. Rec. ITU-T H.831 (01/2015) i Recommendation ITU-T H.831 Conformance of ITU-T H.810 personal health devices: WAN interface Part 1: Web services interoperability: Sender Summary Recommendation IT

10、U-T H.831 is a transposition of Continua Test Tool DG2013, Test Suite Structure Part 1: Web Services Interoperability. Sender (Version 1.4, 2014-01-24), that was developed by the Continua Health Alliance. A number of versions of this specification existed before transposition. This Recommendation in

11、cludes an electronic attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T H.831 2015-01-13 1

12、6 11.1002/1000/12249 _ * To access the Recommendation, type the URL http:/handle.itu.int/ in the address field of your web browser, followed by the Recommendations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T H.831 (01/2015) FOREWORD The International Telecommuni

13、cation Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff q

14、uestions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendat

15、ions on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendatio

16、n, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability

17、or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that complianc

18、e with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or a

19、pplicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to i

20、mplement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2015 All rights reserved. No part of this publication may be reproduced, by an

21、y means whatsoever, without the prior written permission of ITU. Rec. ITU-T H.831 (01/2015) iii Table of Contents Page 1 Scope . 1 2 References . 1 3 Definitions 2 3.1 Terms defined elsewhere 2 3.2 Terms defined in this Recommendation . 2 4 Abbreviations and acronyms 2 5 Conventions 3 6 Test suite s

22、tructure (TSS) . 4 7 Electronic attachment . 5 Annex A Test purposes (TP) . 7 A.1 TP definition conventions . 7 A.2 Subgroup 1.1.1 Basic profile (BP) 8 A.3 Subgroup 1.1.2 Basic security profile (BSP) . 12 A.4 Subgroup 1.1.3 Reliable messaging (RM) 19 Bibliography. 27 Electronic attachment: Electroni

23、c attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. iv Rec. ITU-T H.831 (01/2015) Introduction This Recommendation is a transposition of Continua Test Tool DG2013

24、, Test Suite Structure Part 1: Web Services Interoperability. Sender (Version 1.4, 2014-01-24), that was developed by the Continua Health Alliance. A number of versions of this specification existed before transposition and these can be found in the table below. Version Date Revision history 1.2 201

25、2-10-05 Initial release for Test Tool DG2011. It is the same version as “TSS users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommen

26、dations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T H.810 Recommendation ITU-T H.810 (2013), Interoperability design guidelines for personal health systems. IEEE 11073-20601A IEEE 11

27、073-20601A-2010, IEEE Health informatics Personal health device communication Part 20601: Application profile Optimized Exchange Protocol Amendment 1. OASIS/WS-I BP OASIS/WS-I (2006), Basic Security Profile Version 1.1. OASIS WS-I BSP OASIS/WS-I (2007), Basic Security Profile Version 1.0. OASIS WS-I

28、 RM OASIS (2007), Web Services Reliable Messaging (WS-ReliableMessaging) Version 1.1. _ 1 This Recommendation includes an electronic attachment with the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. 2 Rec. ITU-T H.831 (01/2015) 3 Definition

29、s 3.1 Terms defined elsewhere 3.1.1 agent IEEE 11073-20601A: A node that collects and transmits personal health data to an associated manager. 3.1.2 manager IEEE 11073-20601A: A node receiving data from one or more agent systems. Some examples of managers include a cellular phone, health appliance,

30、set top box, or a computer system. 3.2 Terms defined in this Recommendation None. 4 Abbreviations and acronyms This Recommendation uses the following abbreviations and acronyms: AHD Application Hosting Device ATS Abstract Test Suite ATNA Audit Trail and Node Authentication CDG Continua Design Guidel

31、ines DUT Device Under Test EPR Endpoint Reference GUI Graphical User Interface INR International Normalized Ratio IUT Implementation Under Test MDS Medical Device System NFC Near Field Communication PCO Point of Control and Observation PCT Protocol Conformance Testing PHD Personal Healthcare Device

32、PHDC Personal Healthcare Device Class PHM Personal Health Manager PICS Protocol Implementation Conformance Statement PIXIT Protocol Implementation extra Information for Testing SDP Service Discovery Protocol SOAP Simple Object Access Protocol STR Security Token Reference TCRL Test Case Reference Lis

33、t TCWG Test and Certification Working Group TP Test Purposes URI Uniform Resource Identifier Rec. ITU-T H.831 (01/2015) 3 TSS Test Suite Structure USB Universal Serial Bus WAN Wide Area Network WD WAN Device WDM Windows Driver Model WS Web Service WSDL Web Service Description Language XML extensible

34、 Markup Language 5 Conventions The key words “SHALL“, “SHALL NOT“, “SHOULD“, “SHOULD NOT“, “MAY“, “MAY NOT“ in this document are to be interpreted as in b-ETSI SR 001 262. SHALL is equivalent to must or it is required to. SHALL NOT is equivalent to must not or it is not allowed. SHOULD is equivalent

35、 to it is recommended to. SHOULD NOT is equivalent to it is not recommended to. MAY is equivalent to is permitted. MAY NOT is equivalent to it is not required that. NOTE The above-mentioned key words are capitalized for illustrative purposes only and they do not appear capitalized within this Recomm

36、endation. Reference is made in the ITU-T H.800-series of Recommendations to different versions of the Continua design guidelines (CDG) by a specific designation. The list of terms that may be used in this Recommendation is provided in Table 1. Table 1 List of designations associated to the various v

37、ersions of the CDG CDG name Transposed as Version Description Designation 2013 plus errata ITU-T H.810 4.1 CDG 2013 plus errata noting all ratified bugs. 2013 4.0 Release 2013 of CDG including maintenance updates of the CDG 2012 and additional guidelines that cover new functionalities. Endorphin 201

38、2 plus errata 3.1 CDG 2012 plus errata noting all ratified bugs b-CDG 2012. 2012 3.0 Release 2012 of the CDG including maintenance updates of CDG 2011 and additional guidelines that cover new functionalities. Catalyst 2011 plus errata 2.1 CDG 2011 integrated with identified errata. 2011 2.0 Release

39、2011 of CDG including maintenance updates of CDG 2010 and additional guidelines that cover new functionalities b-CDG 2011. Adrenaline 4 Rec. ITU-T H.831 (01/2015) Table 1 List of designations associated to the various versions of the CDG CDG name Transposed as Version Description Designation 2010 pl

40、us errata 1.6 CDG 2010 integrated with identified errata 2010 1.5 Release 2010 of CDG with maintenance updates of CDG Version 1 and additional guidelines that cover new functionalities b-CDG 2010. 1.5 1.0 - 1.0 First released version of the CDG b-CDG 1.0. 6 Test suite structure (TSS) The test purpos

41、es (TPs) for the WAN interface have been divided into the main subgroups specified below. Annex A describes the TPs for group 1.1 (shown in bold). Group 1: Sender (SEN) Group 1.1: Web services interoperability (WSI) Subgroup 1.1.1: Basic profile (BP) Subgroup 1.1.2: Basic security profile (BSP) Subg

42、roup 1.1.3: Reliable messaging (RM) Group 1.2: SOAP (SOAP) Subgroup 1.2.1: SOAP headers (HEAD) Group 1.3: Audit (ATNA) Subgroup 1.3.1: General (GEN) Subgroup 1.3.2: PCD-01 (PCD-01) Subgroup 1.3.3: Consent management (CM) Group 1.4: PCD-01 HL7 Messages (PCD-01-DATA) Subgroup 1.4.1: General (GEN) Subg

43、roup 1.4.2: Design guidelines (DG) Subgroup 1.4.3: Pulse oximeter (PO) Subgroup 1.4.4: Blood pressure monitor (BPM) Subgroup 1.4.5: Thermometer (TH) Subgroup 1.4.6: Weighing scales (WEG) Subgroup 1.4.7: Glucose meter (GL) Subgroup 1.4.8: Cardiovascular fitness and activity monitor (CV) Subgroup 1.4.

44、9: Strength fitness equipment (ST) Subgroup 1.4.10: Independent living activity hub (HUB) Subgroup 1.4.11: Adherence monitor (AM) Subgroup 1.4.12: Peak expiratory flow monitor (PF) Subgroup 1.4.13: Body composition analyser (BCA) Subgroup 1.4.14: Basic electrocardiograph (ECG) Rec. ITU-T H.831 (01/2

45、015) 5 Group 1.5: Consent management (CM) Subgroup 1.5.1: WAN XDR transaction (TRANS) Subgroup 1.5.2: WAN metadata validation (META) Subgroup 1.5.3: WAN consent directive validation (CDV) Group 2: Receiver (REC) Group 2.1: Web service interoperability (WSI) Subgroup 2.1.1: Basic profile (BP) Subgrou

46、p 2.1.2: Basic security profile (BSP) Subgroup 2.1.3: Reliable messaging (RM) Group 2.2: SOAP (SOAP) Subgroup 2.2.1: SOAP headers (HEAD) Group 2.3: Audit (ATNA) Subgroup 2.3.1: General (GEN) Subgroup 2.3.2: PCD-01 (PCD-01) Subgroup 2.3.3: Consent management (CM) Group 2.4: PCD-01 HL7 Messages (PCD-0

47、1-DATA) Subgroup 2.4.1: General (GEN) Subgroup 2.4.2: Design guidelines (DG) Subgroup 2.4.3: Pulse oximeter (PO) Subgroup 2.4.4: Blood pressure monitor (BPM) Subgroup 2.4.5: Thermometer (TH) Subgroup 2.4.6: Weighing scales (WEG) Subgroup 2.4.7: Glucose meter (GL) Subgroup 2.4.8: Cardiovascular fitne

48、ss and activity monitor (CV) Subgroup 2.4.9: Strength fitness equipment (ST) Subgroup 2.4.10: Independent living activity hub (HUB) Subgroup 2.4.11: Adherence monitor (AM) Subgroup 2.4.12: Peak expiratory flow monitor (PF) Subgroup 2.4.13: Body composition analyser (BCA) Subgroup 2.4.14: Basic electrocardiograph (ECG) Group 2.5: Consent management (CM) Subgroup 2.5.1: WAN XDR transaction (TRANS) Subgroup 2.5.2: WAN service validation (SER) 7 Electronic attachment The protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) req

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1