ITU-T H 845 3-2015 Conformance of ITU-T H 810 personal health devices PAN LAN TAN interface Part 5C Pulse oximeter Agent (Study Group 16)《ITU-T H 810的个人健康设备的一致性 PAN LAN TAN接口部分5C 脉.pdf

上传人:amazingpat195 文档编号:797969 上传时间:2019-02-02 格式:PDF 页数:48 大小:675.29KB
下载 相关 举报
ITU-T H 845 3-2015 Conformance of ITU-T H 810 personal health devices PAN LAN TAN interface Part 5C Pulse oximeter Agent (Study Group 16)《ITU-T H 810的个人健康设备的一致性 PAN LAN TAN接口部分5C 脉.pdf_第1页
第1页 / 共48页
ITU-T H 845 3-2015 Conformance of ITU-T H 810 personal health devices PAN LAN TAN interface Part 5C Pulse oximeter Agent (Study Group 16)《ITU-T H 810的个人健康设备的一致性 PAN LAN TAN接口部分5C 脉.pdf_第2页
第2页 / 共48页
ITU-T H 845 3-2015 Conformance of ITU-T H 810 personal health devices PAN LAN TAN interface Part 5C Pulse oximeter Agent (Study Group 16)《ITU-T H 810的个人健康设备的一致性 PAN LAN TAN接口部分5C 脉.pdf_第3页
第3页 / 共48页
ITU-T H 845 3-2015 Conformance of ITU-T H 810 personal health devices PAN LAN TAN interface Part 5C Pulse oximeter Agent (Study Group 16)《ITU-T H 810的个人健康设备的一致性 PAN LAN TAN接口部分5C 脉.pdf_第4页
第4页 / 共48页
ITU-T H 845 3-2015 Conformance of ITU-T H 810 personal health devices PAN LAN TAN interface Part 5C Pulse oximeter Agent (Study Group 16)《ITU-T H 810的个人健康设备的一致性 PAN LAN TAN接口部分5C 脉.pdf_第5页
第5页 / 共48页
点击查看更多>>
资源描述

1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T H.845.3 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (01/2015) SERIES H: AUDIOVISUAL AND MULTIMEDIA SYSTEMS E-health multimedia services and applications Interoperability compliance testing of personal health systems (HR

2、N, PAN, LAN, TAN and WAN) Conformance of ITU-T H.810 personal health devices: PAN/LAN/TAN interface Part 5C: Pulse oximeter: Agent Recommendation ITU-T H.845.3 ITU-T H-SERIES RECOMMENDATIONS AUDIOVISUAL AND MULTIMEDIA SYSTEMS CHARACTERISTICS OF VISUAL TELEPHONE SYSTEMS H.100H.199 INFRASTRUCTURE OF A

3、UDIOVISUAL SERVICES General H.200H.219 Transmission multiplexing and synchronization H.220H.229 Systems aspects H.230H.239 Communication procedures H.240H.259 Coding of moving video H.260H.279 Related systems aspects H.280H.299 Systems and terminal equipment for audiovisual services H.300H.349 Direc

4、tory services architecture for audiovisual and multimedia services H.350H.359 Quality of service architecture for audiovisual and multimedia services H.360H.369 Telepresence H.420H.429 Supplementary services for multimedia H.450H.499 MOBILITY AND COLLABORATION PROCEDURES Overview of Mobility and Col

5、laboration, definitions, protocols and procedures H.500H.509 Mobility for H-Series multimedia systems and services H.510H.519 Mobile multimedia collaboration applications and services H.520H.529 Security for mobile multimedia systems and services H.530H.539 Security for mobile multimedia collaborati

6、on applications and services H.540H.549 Mobility interworking procedures H.550H.559 Mobile multimedia collaboration inter-working procedures H.560H.569 BROADBAND, TRIPLE-PLAY AND ADVANCED MULTIMEDIA SERVICES Broadband multimedia services over VDSL H.610H.619 Advanced multimedia services and applicat

7、ions H.620H.629 Ubiquitous sensor network applications and Internet of Things H.640H.649 IPTV MULTIMEDIA SERVICES AND APPLICATIONS FOR IPTV General aspects H.700H.719 IPTV terminal devices H.720H.729 IPTV middleware H.730H.739 IPTV application event handling H.740H.749 IPTV metadata H.750H.759 IPTV

8、multimedia application frameworks H.760H.769 IPTV service discovery up to consumption H.770H.779 Digital Signage H.780H.789 E-HEALTH MULTIMEDIA SERVICES AND APPLICATIONS Interoperability compliance testing of personal health systems (HRN, PAN, LAN, TAN and WAN) H.820H.859 Multimedia e-health data ex

9、change services H.860H.869 For further details, please refer to the list of ITU-T Recommendations. Rec. ITU-T H.845.3 (01/2015) i Recommendation ITU-T H.845.3 Conformance of ITU-T H.810 personal health devices: PAN/LAN/TAN interface Part 5C: Pulse oximeter: Agent Summary Recommendation ITU-T H.845.3

10、 is a transposition of Continua Test Tool DG2013, Test Suite Structure Part 5C: Device Specializations. Agent (Pulse Oximeter) (Version 1.5, 2014-01-24), that was developed by the Continua Health Alliance. A number of versions of this specification existed before transposition. This Recommendation i

11、ncludes an electronic attachment with the protocol implementation conformance statements (PICS) and the protocol implementation extra information for testing (PIXIT) required for the implementation of Annex A. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T H.845.3 2015-01-1

12、3 16 11.1002/1000/12264 _ * To access the Recommendation, type the URL http:/handle.itu.int/ in the address field of your web browser, followed by the Recommendations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T H.845.3 (01/2015) FOREWORD The International Teleco

13、mmunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tar

14、iff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recomm

15、endations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommen

16、dation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperabi

17、lity or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that comp

18、liance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTSITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity

19、 or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required

20、 to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2015 All rights reserved. No part of this publication may be reproduced,

21、by any means whatsoever, without the prior written permission of ITU. Rec. ITU-T H.845.3 (01/2015) iii Table of Contents Page 1 Scope . 1 2 References . 2 3 Definitions 2 3.1 Terms defined elsewhere 2 3.2 Terms defined in this Recommendation . 2 4 Abbreviations and acronyms 2 5 Conventions 3 6 Test

22、suite structure (TSS) . 4 7 Electronic attachment . 6 Annex A Test purposes (TPs) . 7 A.1 TP definition conventions . 7 A.2 Subgroup 1.3.3: Pulse oximeter (PO) . 8 Bibliography. 40 Electronic attachment: Protocol implementation conformance statements (PICS) and protocol implementation extra informat

23、ion for testing (PIXIT) required for the implementation of Annex A. iv Rec. ITU-T H.845.3 (01/2015) Introduction This Recommendation is a transposition of Continua Test Tool DG2013, Test Suite Structure Part 5C: Device Specializations. Agent (Pulse oximeter) (Version 1.5, 2014-01-24), that was devel

24、oped by the Continua Health Alliance. A number of versions of this specification existed before transposition and these can be found in the table below. Version Date Revision history 1.2 2012-10-05 Initial release for Test Tool DG2011. This is the same version as “TSS users of this Recommendation ar

25、e therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published.The reference to a document within this Recommendation does not give it, as a

26、 stand-alone document, the status of a Recommendation. ITU-T H.810 Recommendation ITU-T H.810 (2013), Interoperability design guidelines for personal health systems. ISO/IEEE 11073-20601A ISO/IEEE 11073-20601:2010, IEEE Health informatics Personal health device communication Part 20601: Application

27、profile Optimized exchange protocol, including ISO/IEEE 11073-20601:2010 Amd 1:2015. with ISO/IEEE 11073-104xx ISO/IEEE 11073-104xx (in force), Health informatics Personal health device communication Device specialization. NOTE This is shorthand to refer to the collection of device specialization st

28、andards that utilize ISO/IEEE 11073-20601A, where xx can be any number from 01 to 99, inclusive. ISO/IEEE 11073-10404 ISO/IEEE 11073-10404:2008, Health informatics Personal health device communication Device specialization Pulse oximeter. ISO/IEEE 11073-20601 ISO/IEEE 11073-20601:2010, Health inform

29、atics Personal health device communication Part 20601 Application profile Optimized exchange protocol. 3 Definitions 3.1 Terms defined elsewhere This Recommendation uses the following terms defined elsewhere: 3.1.1 agent ISO/IEEE 11073-20601A: A node that collects and transmits personal health data

30、to an associated manager. 3.1.2 manager ISO/IEEE 11073-20601A: A node receiving data from one or more agent systems. Some examples of managers include a cellular phone, health appliance, set top box, or a computer system. 3.2 Terms defined in this Recommendation None. 4 Abbreviations and acronyms Th

31、is Recommendation uses the following abbreviations and acronyms: ATS Abstract Test Suite DUT Device Under Test CDG Continua Design Guidelines Rec. ITU-T H.845.3 (01/2015) 3 GUI Graphical User Interface INR International Normalized Ratio IUT Implementation Under Test MDS Medical Device System NFC Nea

32、r Field Communication PAN Personal Area Network PCT Protocol Conformance Testing PCO Point of Control and Observation PHD Personal Healthcare Device PHDC Personal Healthcare Device Class PHM Personal Health Manager PICS Protocol Implementation Conformance Statement PIXIT Protocol Implementation extr

33、a Information for Testing SDP Service Discovery Protocol SOAP Simple Object Access Protocol TCRL Test Case Reference List TCWG Test and Certification Working Group TP Test Purpose TSS Test Suite Structure USB Universal Serial Bus WDM Windows Driver Model 5 Conventions The key words “SHALL“, “SHALL N

34、OT“, “SHOULD“, “SHOULD NOT“, “MAY“, “MAY NOT“ in this document are to be interpreted as in b-ETSI SR 001 262. SHALL is equivalent to must or it is required to. SHALL NOT is equivalent to must not or it is not allowed. SHOULD is equivalent to it is recommended to. SHOULD NOT is equivalent to it is no

35、t recommended to. MAY is equivalent to is permitted. MAY NOT is equivalent to it is not required that. NOTE The above-mentioned key words are capitalized for illustrative purposes only and they do not appear capitalized within this Recommendation. Reference is made in the ITU-T H.800-series of Recom

36、mendations to different versions of the Continua Design Guidelines (CDG) by a specific designation. The list of terms that may be used in this Recommendation is provided in Table 1. 4 Rec. ITU-T H.845.3 (01/2015) Table 1 List of designations associated with the various versions of the CDG CDG name T

37、ransposed as Version Description Designation 2013 plus errata ITU-T H.810 4.1 CDG 2013 plus errata noting all ratified bugs. - 2013 - 4.0 Release 2013 of the CDG including maintenance updates of CDG 2012 and additional guidelines that cover new functionalities. Endorphin 2012 plus errata - 3.1 CDG 2

38、012 plus errata noting all ratified bugs b-CDG 2012. - 2012 - 3.0 Release 2012 of the CDG including maintenance updates of CDG 2011 and additional guidelines that cover new functionalities. Catalyst 2011 plus errata - 2.1 CDG 2011 integrated with identified errata. - 2011 - 2.0 Release 2011 of the C

39、DG including maintenance updates of CDG 2010 and additional guidelines that cover new functionalities b-CDG 2011. Adrenaline 2010 plus errata - 1.6 CDG 2010 integrated with identified errata - 2010 - 1.5 Release 2010 of the CDG with maintenance updates of CDG Version 1 and additional guidelines that

40、 cover new functionalities b-CDG 2010. 1.5 1.0 - 1.0 First released version of the CDG b-CDG 1.0. - 6 Test suite structure (TSS) The test purposes (TPs) for the PAN/LAN/TAN interface have been divided into the main subgroups specified below. Annex A describes the TPs for subgroup 1.3.3 (shown in bol

41、d). Group 1: Agent (AG) Group 1.1: Transport (TR) Subgroup 1.1.1: Design guidelines: Common (DGC) Subgroup 1.1.2: USB design guidelines (UDG) Subgroup 1.1.3: Bluetooth design guidelines (BDG) Subgroup 1.1.4: Pulse oximeter design guidelines (PODG) Subgroup 1.1.5: Cardiovascular design guidelines (CV

42、DG) Subgroup 1.1.6: Activity hub design guidelines (HUBDG) Subgroup 1.1.7: ZigBee design guidelines (ZDG) Subgroup 1.1.8: Glucose meter design guidelines (GLDG) Subgroup 1.1.9: Bluetooth low energy design guidelines (BLEDG) Subgroup 1.1.10: Basic electrocardiograph design guidelines (ECGDG) Subgroup

43、 1.1.11: NFC design guidelines (NDG) Group 1.2: Optimized exchange protocol (OXP) Subgroup 1.2.1: PHD domain information model (DIM) Rec. ITU-T H.845.3 (01/2015) 5 Subgroup 1.2.2: PHD service model (SER) Subgroup 1.2.3: PHD communication model (COM) Group 1.3: Devices class specializations (CLASS) S

44、ubgroup 1.3.1: Weighing scales (WEG) Subgroup 1.3.2: Glucose meter (GL) Subgroup 1.3.3: Pulse oximeter (PO) Subgroup 1.3.4: Blood pressure monitor (BPM) Subgroup 1.3.5: Thermometer (TH) Subgroup 1.3.6: Cardiovascular (CV) Subgroup 1.3.7: Strength (ST) Subgroup 1.3.8: Activity hub (HUB) Subgroup 1.3.

45、9: Adherence monitor (AM) Subgroup 1.3.10: Insulin pump (IP) (Future development) Subgroup 1.3.11: Peak flow (PF) Subgroup 1.3.12: Body composition analyser (BCA) Subgroup 1.3.13: Basic electrocardiograph (ECG) Subgroup 1.3.14: International normalized ratio (INR) Group 1.4: Personal health device t

46、ranscoding whitepaper (PHDTW) Subgroup 1.4.1: Whitepaper general requirements (GEN) Subgroup 1.4.2: Whitepaper thermometer requirements (TH) Subgroup 1.4.3: Whitepaper blood pressure requirements (BPM) Subgroup 1.4.4: Whitepaper heart rate requirements (HR) Subgroup 1.4.5: Whitepaper glucose meter r

47、equirements (GL) Group 2: Manager (MAN) Group 2.1: Transport (TR) o Subgroup 2.1.1: Design guidelines: Common (DGC) o Subgroup 2.1.2: USB design guidelines (UDG) o Subgroup 2.1.3: Bluetooth design guidelines (BDG) o Subgroup 2.1.4: Cardiovascular design guidelines (CVDG) o Subgroup 2.1.5: Activity h

48、ub design guidelines (HUBDG) o Subgroup 2.1.6: ZigBee design guidelines (ZDG) o Subgroup 2.1.7: Bluetooth low energy design guidelines (BLEDG) o Subgroup 2.1.8: NFC design guidelines (NDG) Group 2.2: 20601: Optimized exchange protocol (OXP) Subgroup 2.2.1: General (GEN) Subgroup 2.2.2: PHD domain in

49、formation model (DIM) Subgroup 2.2.3: PHD service model (SER) Subgroup 2.2.4: PHD communication model (COM) Group 2.3: Devices class specializations (CLASS) 6 Rec. ITU-T H.845.3 (01/2015) Subgroup 2.3.1: Weighing scales (WEG) Subgroup 2.3.2: Glucose meter (GL) Subgroup 2.3.3: Pulse oximeter (PO) Subgroup 2.3.4: Blood pressure monitor (BPM) Subg

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1