KS C 6594-2007 Performance requirements for instruments used to detect oxygen-deficient oxygen-enriched atmospheres《氧传感器的性能测试方法》.pdf

上传人:amazingpat195 文档编号:816227 上传时间:2019-02-12 格式:PDF 页数:26 大小:391.74KB
下载 相关 举报
KS C 6594-2007 Performance requirements for instruments used to detect oxygen-deficient oxygen-enriched atmospheres《氧传感器的性能测试方法》.pdf_第1页
第1页 / 共26页
KS C 6594-2007 Performance requirements for instruments used to detect oxygen-deficient oxygen-enriched atmospheres《氧传感器的性能测试方法》.pdf_第2页
第2页 / 共26页
KS C 6594-2007 Performance requirements for instruments used to detect oxygen-deficient oxygen-enriched atmospheres《氧传感器的性能测试方法》.pdf_第3页
第3页 / 共26页
KS C 6594-2007 Performance requirements for instruments used to detect oxygen-deficient oxygen-enriched atmospheres《氧传感器的性能测试方法》.pdf_第4页
第4页 / 共26页
KS C 6594-2007 Performance requirements for instruments used to detect oxygen-deficient oxygen-enriched atmospheres《氧传感器的性能测试方法》.pdf_第5页
第5页 / 共26页
点击查看更多>>
资源描述

1、 KSKSKSKSKSKSKSK KSKSKS KSKSK KSKS KSK KS KS C 6594 KS C 6594: 2007(2013 ) 2007 11 30 http:/www.kats.go.krKS C 6594: 2007 : ( ) ( ) ( ) : (http:/www.standard.go.kr) : :2007 11 30 :2013 3 27 2013-0117 : : ( 02-509-7294) (http:/www.kats.go.kr). 10 5 , . KS C 6594: 2007 i 1 1 2 2 3 .2 4 4 5 5 5.1 (Gene

2、ral) 5 5.2 , (Meters, indicators and outputs) 5 5.3 (Alarm or output function).5 5.4 (Trouble signals).6 5.5 (Controls and adjustments) 6 5.6 (Consumables) 6 6 6 6.1 (Marking on instruments).6 6.2 (Instruction manual)7 7 8 7.1 (General) 8 7.2 (Sequence)8 7.3 (Preparation of instrument) 8 7.4 (Condit

3、ions for test and test area)8 7.5 (Non-powered transportation).9 7.6 (Drop test) 9 7.7 (Vibration)10 7.8 (Calibration).10 7.9 (Accuracy)10 7.10 (Repeatability)11 7.11 (Step change response and recovery) .11 7.12 (Supply voltage variation)12 7.13 (Temperature variation)14 7.14 (Humidity variation).14

4、 7.15 (Position sensitivity) .14 7.16 (Air velocity variation) 15 7.17 (Radio frequency interference: RFI) 15 7.18 (Long-term stability) 16 7.19 (Battery and low-battery voltage alarm)16 7.20 (Exposure to high concentration gas)17 .18 KS C 6594: 2007 (2013 ) Performance requirements for instruments

5、used to detect oxygen-deficient/oxygen-enriched atmospheres 1 1.1 . 1.2 , , . . . 20.9 % (21.2 kPa), 78.1 % (79.1 kPa), 1 % (1.01 kPa) . 1.3 250 V , . 1.4 10 50 . 1.5 15 20.9 %(15.2 21.2 kPa) 20.9 25.0 %(21.225.3 kPa) . “% ” . 1.6 18 % (18.2 kPa) 25 % (25.3 kPa) . 1.7 , ( 20.9 % 21.2 kPa) . 1.8 , 15

6、 % (15.2 kPa) 30 % (30.4 kPa) . , . 1.9 . . KS C 6594: 2007 2 2 . . ( ) . KS C 6593, , KS C IEC 60079 0, KS C IEC 61000 6 2, (EMC) 6: 2: KS C IEC 61000 6 4, (EMC) 6: 4: KS C IEC 61010 1, , 1: 3 . 3.1 (clean air) 3.2 (normal atmosphere) 980.665 cm/s2, 13.595 1 g/cm3 76 cm 1 1.013 25106dyne/cm2 101.32

7、5 kPa 760.00 mm Hg 0 . 3.3 (oxygen deficiency) 3.4 (oxygen enrichment) 3.5 (alarm) , 3.6 (alarm set-point) , KS C 6594: 2007 3 3.7 (span) 3.8 (calibration) , (span) 3.9 (calibration gas) 3.10 (range) 3.11 (test gas) 0.25 % 3.12 (oxygen-monitoring instrument) , . “ ” “ ” “ ” . 3.13 (detector head) ,

8、. . . 3.14 (oxygen-sensing element) 3.15 (control unit) , , 3.16 (diffusion) KS C 6594: 2007 4 3.17 (sample draw) 3.18 (signal-processing detector head) , , 3.19 (alarm-only instrument) 3.20 (mobile instrument) 3.21 (portable instrument) , 8 . 3.22 (stationary instrument) 3.23 (trouble signal) , , ,

9、 , 3.24 (nominal voltage) . 4 4.1 KS C IEC 61010 1 , . 4.2 KS C IEC 60079 0 . . . 4.3 . , KS C 6594: 2007 5 . 5 5.1 (General) 5.1.1 , . 5.1.2 . 5.2 , (Meters, indicators and outputs) 5.2.1 . 5.2.2 , . 5.2.3 . 5.2.4 (: 4 20 mA) , . 5.2.5 . a) , , b) , . c) . 5.2.6 . , . 5.3 (Alarm or output function)

10、 5.3.1 . , , , . 5.3.2 , . . , . 5.3.3 . . KS C 6594: 2007 6 5.3.4 16 25 % . , 25 % . 5.3.5 . 5 . 5.4 (Trouble signals) 5.4.1 , . a) b) c) d) . , . 5.4.2 , . , . 5.5 (Controls and adjustments) 5.5.1 . 5.5.2 . 5.6 (Consumables) 5.6.1 10 15 ( , ) 8 . 5.6.2 8 . 6 6.1 (Marking on instruments) 6.1.1 4.2

11、. 6.1.2 . a) , , . KS C 6594: 2007 7 b) , . 6.1.3 “: ” . 1 . , . 2 , , . 3 , . 6.1.4 , . 6.1 . 6.1.5 . . 6.1.6 15 25 % . 6.2 (Instruction manual) 6.2.1 . a) , , . b) c) d) e) f) g) ( , , ) h) i) ( , , , , , , , , , ) j) , k) , l) , KS C 6594: 2007 8 m) , , , n) o) p) , q) , r) , s) t) , u) 6.2.2 , .

12、 20 30 %, 40 60 %, 70 90 % . 6.2.3 6.2.1 6.2.2 . 7 7.1 (General) 7.1.1 , . 7.1.2 . 7.2 (Sequence) . 7.11 7.17 7.10 , 7.18 . 7.3 (Preparation of instrument) 7.3.1 . 7.3.2 , , . 7.3.3 , . 7.4 (Conditions for test and test area) 7.4.1 , 2 % . 7.4.2 15 25 . KS C 6594: 2007 9 . 7.4.3 30 70 % . . 7.4.4 ,

13、1 m/s . 7.4.5 7.7 7.20 , , . 7.4.6 , . (: ) . , 7.4.2 7.4.4 . 7.4.7 7.7 7.20 . 7.4.2 7.4.3 . 7.4.8 , , . 5 , . 0.2 % . 7.4.9 0.5 % . 7.4.10 , , 7.9 7.17 . 7.5 (Non-powered transportation) . a) 24 ( 253) b) 24 c) 24 (602) d) 24 e) 5 1 (101.3 kPa) 0.5 (50.7 kPa) 2 , 5 1 f) 24 7.6 (Drop test) 7.6.1 . K

14、S C 6594: 2007 10 7.6.2 ( ) 1 m . 7.6.3 7.6.2 3 , , . 7.6.4 , . . 7.6.5 , 7.7 20.9 % . 7.7 (Vibration) 7.7.1 ( ) . 7.7.2 , . 1 . , 10 Hz . a) 1) 10 30 Hz, 1.0 mm 2) 31 150 Hz, 2 g b) 1) 10 30 Hz, 1.0 mm 2) 31 100 Hz, 2 g 7.7.3 . . , . . 7.8 (Calibration) 7.8.1 . 7.8.2 . 7.8.3 0.5 % . 7.9 (Accuracy) 7.9.1 , 0.5 % . KS C 6594: 2007 11 7.9.2