1、KSKSKSKS SKSKSKS KSKSKS SKSKS KSKS SKS KS 2006 4 14 http:/www.kats.go.krKS C IEC 62128 1 1: KS C IEC 62128 1: 2006 (2011 ) C IEC 62128 1: 2006 : ( ) ( ) () ( ) : (http:/www.standard.go.kr) : : 2006 4 14 : 2011 12 28 2011-0694 : : ( 02-509-7294) (http:/www.kats.go.kr). 10 5 , . C IEC 62128 1: 2006 i
2、1 1. 1 2. 1 3. 2 3.1 2 3.2 2 3.3 3 3.4 5 3.5 5 3.6 6 3.7 7 3.8 7 3.9 8 3.10 8 4. 1 kV a.c./1.5 kV d.c. 8 4.1 8 4.2 18 4.3 19 4.4 1.5 kV d.c. (:) 19 5. 1 kV a.c./1.5 kV d.c. 25 kV a.c./d.c. 20 5.1 20 5.2 27 5.3 28 6. 28 6.1 28 6.2 , , 32 C IEC 62128 1: 2006 ii 6.3 39 7. 40 7.1 40 7.2 AC 40 7.3 DC 41
3、8. 43 9. 43 10. 44 11. 44 A() 45 B() 47 C() 48 D() / 51 E() / 56 57 ICS 45.060 KS C IEC 1: 62128 1: 2006(2011 ) Railway applications Fixed installations Part 1: Protective provisions relating to electrical safety and earthing 2003 1 IEC 62128 1 Railway applications Fixed installations Part 1:Protect
4、ive provisions relating to electrical safety and earthing . 1. a.c. d.c. . . , . . , , , . , , , ( ) 2. . . , ( ) . KS C IEC 60077 1 1: (Railway applications Electric equipment for rolling stock Part 1: General service conditions and general rules) C IEC 62128 1: 2006 2 KS C IEC 60364 4 41 4 41: (El
5、ectrical installations of buildings Part 4 41: Protection for safety Protection against electric shock) KS C IEC 60529 (IP )Degrees of protection provided by enclosures(IP Code) KS C IEC 60664 1 1: , (Insulation coordination for equipment within low voltage systems Part 1: Principles, requirements a
6、nd tests) KS C IEC 60850 (Railway applications Supply voltages of traction systems) KS C IEC 60913: 2003 (Electric traction overhead lines) KS C IEC 61140 (Protection against electric shock Common aspects for installation and equipment) KS C IEC 61991 (Railway applications Rolling stock Protective p
7、rovisions against electrical hazards) KS C IEC 62128 2 2: (Railway applications Fixed installations Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems) IEC 60466 1 kV 38 kV AC (AC insulation-enclosed switchgear and controlgear for rated voltages above
8、 1 kV and up to and including 38 kV) IEC 60479 1 1: (Effects of current on human beings and livestock Part 1: General aspects) IEC 60742 (Isolating transformers and safety isolating transformers Requirements) IEC 61936 1 1 kV a.c. 1: (Power installations exceeding 1 kV a.c.Part 1: Common rules) ISO
9、3864 (Safety colours and safety signs) 3. . 3.1 . , , 3.2 3.2.1 () (traction) substation , ( ) 3.2.2 () (traction) switching station , 3.2.3 (feeding section) C IEC 62128 1: 2006 3 3.2.4 (feeder) 3.2.5 (feeding point) 3.3 3.3.1 (contact line) IEV 811 33 01 3.3.2 (overhead contact line system) . (cat
10、enary), , , , , 3 , , , , 3.3.3 (overhead contact line) , . 3.3.4 (overhead line) . 3.3.5 (catenary) 3.3.6 (contact wire) IEV 811 33 15 3.3.7 (lightning protection wire) 3.3.8 (overhead contact line zone and panto graph zone) , . 1 . X, Y, Z . HP , . . . (out of running overhead contact line) , . (o
11、verhead position) 3 , . . . C IEC 62128 1: 2006 4 RH HP OZ PZ TCL X OZ, Y PZ Z RH (stagger) “Y” . 1 3.3.9 (earth wire) , . . 3.3.10 (line feeder) 3.3.11 (reinforcing feeder) , 3.3.12 ( ) supports (in electric traction) IEV 811 33 19 3.3.13 mast (in electric traction) 3.3.14 (stagger) . 3.3.15 (secti
12、on insulator) , C IEC 62128 1: 2006 5 IEV 811 36 15 3.3.16 3(conductor rail) . (shoegear) . 3.3.17 3(overhead conductor rail) 3.3.18 (out of running overhead contact line) 3.4 3.4.1 (return circuit) . 3 3.4.2 (track return system) 3.4.3 (return conductor) , 3.4.4 3(return conductor rail) 3 3.4.5 (return cable) 3.4.6 (rail joint bond) 3.4.7 (insulated rail joint) 3.4.8 (rail-to-rail cross bond) 3.4.9 (track-to-track cross bond) 3.4.10 (track circuit) . . IEV 821 03 01 . 3.4.11 (impedance bond)