1、I INCH-POUND I A-A-50505 November 8, 1991 COMMERCIAL ITEM DESCRIPTION CONNECTOR ASSEMBLY, ELECTRICAL, IN-LINE The General Services Administration has authorized the use of this commercial item description. Abstract. This CID covers an electrical three phase, three pole, polarized, 600 volt, in-line

2、connector for surface or submarine shore to ship power use. Both male and female assemblies are to be capable of attaching to existing Navy 3/C THOF-500 MCM cable. Salient characteristics. 1. Reauirements. The connectors shall be rated for a three pole, three phase ungrounded 600 volt, Delta electri

3、cal distribution system. The connectors shall be rated for an alternating current (ac) load of 500 amperes, 60 Hertz, and shall be capable of attachment to a 3/C THOF-500 MCM Navy cable. The connectors shall be designed for an in-line, quick lock slide sleeve, type of connector. The connectors shall

4、, as a minimum, consist of mating male and female plugs, protective caps with chains, grommets, clamps, couplings, set screws, sleeves, raceways and other hardware parts as needed to effect a completed connection. The connectors shall be of a design that allows field assembly, and shall be manufactu

5、red to be water tight, when assembled with mating receptacle or protective cover cap. 2. Material. The connectors shall be constructed of molded neoprene and shall have rubber coated manganese bronze shells. The current carrying contact material shall be copper conforming to ASTM B-301, alloy no. C1

6、4500 or C18700. Current carrying parts shall be silver plated, in accordance with Type II or Type III, Grade A, of Federal Specification QQ-S-365. IBeneficial comments (recommendations, additions, deletions) and any pertinent1 ldata which may be of use in improving this document should be addressed

7、to: I ICommanding Officer (Code 156), Naval Construction Battalion Center, Port I IHueneme. CA 93043-5000. I FSC 5935 DISTRIBUTION STATEMENT A. Approved for public release; distribution is a unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

8、A-A- 50505 3. Identification marking. The connectors shall be clearly and permanently marked for identification with the following information as a minimum: c a. Manufacturers identification b. Contract number c. Serial number (alpha-numeric sequence at option of contractor) d. Field assembly instru

9、ctions e. Phase rotation identification (A,B,C) Marking shall be on identification/information plates or directly on the item at the option of the manufacturer. Qualitv assurance Drovisions. 1. 2. 3. 4. 5. Responsibilitv for tests. Unless otherwise specified in the contract, the contractor is respon

10、sible for the performance of all test requirements as specified herein. Unless disapproved by the Government, except as otherwise specified in the contract, the contractor may use his own or any other facilities suitable for the performance of the test requirements specified herein. Qualitv conforma

11、nce tests. The quality conformance tests shall be performed on sample connectors selected in accordance with the inspection lot and sampling requirements. This inspection shall include examination and operational tests as specified herein. Inspection lot. All units offered to the Government at one t

12、ime shall be considered a lot for purposes of inspection, A sample unit shall be one complete connector (male and female). Examination. Each sample selected in accordance with the inspection lot and sampling requirements shall be examined for compliance with the salient characteristics requirements

13、specified herein. This element of inspection shall encompass all visual examinations and dimensional measurements, Noncompliance with any specified requirements or presence of one or more defects preventing or lessening maximum efficiency shall constitute cause for rejection. Contact resistance test

14、. Mated units shall be tested to comply with method 307 of MIL-STD-202. The connectors shall show no Contact resistance above the limits shown in table I. The following details shall apply: a. Test current: 300 Amperes (A) through each bus lug. b. Number of measurements: Three (minimum) to determine

15、 average millivolt drop. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A- 50505 TABLE I. Contact resistance. I I A I B I C I I I I I I I (ampere) I I and durability I millivolt drop1 I I I -(max I -(max I I 300 I 8 I 11 I 11 I I I I I I I Test

16、current I Contact milli- I Millivolt drop I Contact and I I per phase I volt drop (max)l after salt spray I cable crimp I 6. Dielectric withstanding voltage test. Mated connectors shall be tested per method 301 of MIL-STD-202 for 1 minute. The following details shall apply: a. Nature of potential: a

17、lternating current (ac) b. Magnitude of voltage: 2500 volts (V) root mean square (rms) c. Points of application: The potential shall be applied between each phase and metal part and between each phase and all adjacent phases. 7. Pull-out strength test. Individual connectors, attached to the 3/C THOF

18、-500 MCM Navy cable, shall have sufficient force applied to pull the cable out of the connector. The force required to pull out shall not be less than 1500 pounds. 8. Engaging and disengagina forces test. Engaging and disengaging forces shall not exceed 50 pounds. Contractor certification. The contr

19、actor shall certify, and maintain substantiating evidence, that the product offered meets the salient characteristics of this CID and that the product conforms to the producers own drawings, specifications, standards, and quality assurance practices. The government reserves the right to require proo

20、f of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. Metric Droducts. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, provided they fall with

21、in specified tolerances using conversion tables contained in the latest revision of FED-STD-376, and all other requirements of this CID are met, If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch/pound units, a request should be made to

22、 the contracting officer to determine if the product is acceptable. The contracting officer has the option of accepting or. rejecting the product, Regulatory reauirements. The offerer/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent pract

23、icable, Packaging. Unless otherwise specified in the contract or order, the preservation, packing, and marking shall be in accordance with ASTM D 3951. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A50505 59 9999974 0062881 T A-A-50505 MIL-STD-

24、202, QQ-S-365 and FED-STD-376 are available from Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19103. Possible sources of supply: a. Crouse-Hinds Molded Products, Cooper Industries - Joy In-Line Shore/Power Connectors, Assembly Numbers X8998-1 and X8998-2. Comp

25、etition is not limited to this product, but may be a better or equal product of another manufacturer. MILITARY INTERESTS: Custodian Navy - YD User Activity DIA - ES PREPARING ACTIVITY: Navy - YD (Project 5935-3871) 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ETSI EN 300 188-4-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Three Party (3PTY) Supplementary Service Part 4 Abstra_1.pdf ETSI EN 300 188-4-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Three Party (3PTY) Supplementary Service Part 4 Abstra_1.pdf
  • ETSI EN 300 188-5-1998 Integrated Services Digital Network (ISDN) Three Party (3PTY) Supplementary Service Digital Subscriber Signalling System No One (DSS1) Protocol Part 5 Test S.pdf ETSI EN 300 188-5-1998 Integrated Services Digital Network (ISDN) Three Party (3PTY) Supplementary Service Digital Subscriber Signalling System No One (DSS1) Protocol Part 5 Test S.pdf
  • ETSI EN 300 188-5-1998 Integrated Services Digital Network (ISDN) Three Party (3PTY) Supplementary Service Digital Subscriber Signalling System No One (DSS1) Protocol Part 5 Test S_1.pdf ETSI EN 300 188-5-1998 Integrated Services Digital Network (ISDN) Three Party (3PTY) Supplementary Service Digital Subscriber Signalling System No One (DSS1) Protocol Part 5 Test S_1.pdf
  • ETSI EN 300 188-6-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Three Party (3PTY) Supplementary Service Part 6 Abstra.pdf ETSI EN 300 188-6-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Three Party (3PTY) Supplementary Service Part 6 Abstra.pdf
  • ETSI EN 300 188-6-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Three Party (3PTY) Supplementary Service Part 6 Abstra_1.pdf ETSI EN 300 188-6-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Three Party (3PTY) Supplementary Service Part 6 Abstra_1.pdf
  • ETSI EN 300 189-1999 Private Integrated Services Network (PISN) Addressing (V1 2 1 ISO IEC 11571 (1998) Modified)《专用综合业务网(PISN) 寻址(版本1 2 1) ISO IEC 11571(1998) 修正本》.pdf ETSI EN 300 189-1999 Private Integrated Services Network (PISN) Addressing (V1 2 1 ISO IEC 11571 (1998) Modified)《专用综合业务网(PISN) 寻址(版本1 2 1) ISO IEC 11571(1998) 修正本》.pdf
  • ETSI EN 300 195-1-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Supplementary Service Interactions Part 1 Protocol Spe.pdf ETSI EN 300 195-1-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Supplementary Service Interactions Part 1 Protocol Spe.pdf
  • ETSI EN 300 195-1-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Supplementary Service Interactions Part 1 Protocol Spe_1.pdf ETSI EN 300 195-1-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Supplementary Service Interactions Part 1 Protocol Spe_1.pdf
  • ETSI EN 300 195-2-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Supplementary Service Interactions Part 2 Protocol Imp.pdf ETSI EN 300 195-2-2002 Integrated Services Digital Network (ISDN) Digital Subscriber Signalling System No One (DSS1) Protocol Supplementary Service Interactions Part 2 Protocol Imp.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1