NAVY A-A-50622-1994 SURGE SUPPRESSOR FOR SHIPBOARD PERSONAL COMPUTERS AND PERIPHERAL EQUIPMENTS《船只个人电脑及外围设备震荡抑止器》.pdf

上传人:appealoxygen216 文档编号:976319 上传时间:2019-03-13 格式:PDF 页数:5 大小:186.68KB
下载 相关 举报
NAVY A-A-50622-1994 SURGE SUPPRESSOR FOR SHIPBOARD PERSONAL COMPUTERS AND PERIPHERAL EQUIPMENTS《船只个人电脑及外围设备震荡抑止器》.pdf_第1页
第1页 / 共5页
NAVY A-A-50622-1994 SURGE SUPPRESSOR FOR SHIPBOARD PERSONAL COMPUTERS AND PERIPHERAL EQUIPMENTS《船只个人电脑及外围设备震荡抑止器》.pdf_第2页
第2页 / 共5页
NAVY A-A-50622-1994 SURGE SUPPRESSOR FOR SHIPBOARD PERSONAL COMPUTERS AND PERIPHERAL EQUIPMENTS《船只个人电脑及外围设备震荡抑止器》.pdf_第3页
第3页 / 共5页
NAVY A-A-50622-1994 SURGE SUPPRESSOR FOR SHIPBOARD PERSONAL COMPUTERS AND PERIPHERAL EQUIPMENTS《船只个人电脑及外围设备震荡抑止器》.pdf_第4页
第4页 / 共5页
NAVY A-A-50622-1994 SURGE SUPPRESSOR FOR SHIPBOARD PERSONAL COMPUTERS AND PERIPHERAL EQUIPMENTS《船只个人电脑及外围设备震荡抑止器》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、A-A-50b22 1919974 0363524 09b 1 INCH-POUND 1 A-A-50622 14 March 1994 COMMERCIAL ITEM DESCRIPTION SURGE SUPPRESSOR FOR SHIPBOARD PERSONAL COMPUTERS AND PERIPHERAL EQUIPMENTS The General Services Administration has authorized the use of this Commercial Item Description. Abstract. This Commercial Item

2、Description covers cord-connected surge suppressors with or without individual switches for receptacles. These transient voltage surge suppressors (TVSS) are intended to limit the maximum amplitude of transient voltage surges on shipboard power lines that supply personal computers and other peripher

3、al equipment. These CID requirements cover hybrid surge suppressors: an assembly of series and parallel, or any combination of suppression elements with compatible filter devices to limit voltages, current or both to a specified level. The hybrid TVSS shall include sine wave clamping capability, mul

4、tiple stage surge clamping, and an EMI/RFI noise filtering network. 0 These transient voltage surge suppressors are intended to be installed on the load side of the ships branch overcurrent protection device and operate on an ungrounded delta electrical system. They are not intended to function as s

5、urge arrestors. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 03R42, 2531 Jefferson Davis Hwy, Arlington, VA 22242-5160, by using the self-addressed S

6、tandardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 6150 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. O Provided by IHSNot for ResaleNo reproduction or networking permitted without license f

7、rom IHS-,-,-A-A-50622 9599974 01ib3525 T22 I - -1 A-A-50622 Salient characteristics. The product shall be certified by a nationally recognized testing laboratory (NRTL) accredited for TVSS certification by the Occupational Safety and Health Administration (OSHA), U.S. Department of Labor for complia

8、nce with UL Standard of Safety “Transient Voltage Surge Suppressorsft, UL 1449 (including any Marine supplements) and the requirements specified herein. 1. 2. 3. 4. 5. 6. 7. The TVSS shall be designed to limit the transient voltage surge to a maximum amplitude when subjected to a 1.2 by 50.0 microse

9、cond 6000 volt, 500 ampere ringwave surge. Types. The surge suppressor shall be a two-port device per UL 1449 and shall be one of the following types. a. Cord-connected b. Power control-center (Power control-center is a TVSS with individual power (on-off) switches for all receptacles.) Protection mo

10、des. All surge suppressors are for use in an ungrounded electrical system and shall provide protection for common mode (line-to-ground) and normal mode (line-to- line) transients. Electrical ratinq. The surge suppressor shall be rated for continuous duty at nominally 115 volts, single phase, 15 ampe

11、res. Voltaqe protection level. Either 330 or 400 volts per UL STD 1449 ratings (all modes). Response time. Shall be less than 50 nanoseconds. Sumlementarv protection. All surge suppressors shall be furnished with the following: a. Circuit breaker. A double-pole circuit breaker shall provide overcurr

12、ent protection on both sides of the AC supply line. The breaker shall include a press-to-reset feature. b. Temperature protective device. Surge suppressors using MOVs for normal mode protection shall include a non- resettable thermal cutoff device that senses the internal temperature of the enclosur

13、e and interrupts both sides of the supply source. The thermal cutoff device shall be rated between 90C and 100C. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-c*. A-A-50b22 9 9999974 OLb352b 9b 9 A-A-5 O 62 2 c. Surge protection indicator. Surge

14、suppressors shall include a visible indicator to show that the surge suppression circuitry is not damaged. 8. Enclosure. The surge suppressor enclosure shall be metallic. 9. Switches. The following double-pole switches shall be furnished. a. A main power switch (On-Off) shall be included that de- en

15、ergizes both lines and the entire surge suppressor unit. The main switch shall be clearly labeled as such. The circuit breaker may be used for this function. b. For power control-center type TVSS, individual switches (On-Off) shall be provided for each receptacle. 10. Receptacles. Receptacles used i

16、n TVSS shall be general purpose, 2 pole, 3 wire, 15 ampere, 125 volts, single or parallel-duplex type. TVSS shall have a minimum of 5 receptacles unless otherwise specified. 11. Cord. The supply cord shall be permanently attached to the suppressor. a. Flexible cords acceptable are types S, SO, SJ, a

17、nd SJO. b. Length of supply cord shall be 6-feet unless otherwise specified in ordering data. 12. Operatinq/Storage temperature. The TVSS shall be able to The operate within a temperature range of -10C to 60C. TVSS must be capable of being stored in a temperature range of -30C to 70C without affecti

18、ng its subsequent operation. mounting provisions to permit units to be bulkhead, deck or table mounted. 13. Mounting Provisions. Surge suppressors shall include 14. Bid samples. When specified in the solicitation, bid samples shall be furnished. pualitv assurance Drovisions. 1. Contractor Certificat

19、ion. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this Commercial Item Description, and that the product conforms to the producers own drawings, - 3 Provided by IHSNot for ResaleNo reproduction or networking permitted

20、 without license from IHS-,-,-A-A-50b22 m 9997774 0363527 8T5 m A-A-5 O 62 2 .fm specifications, standards and quality assurance practices. The government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisi

21、ons of the contract. 2. Metric Products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, provided they fall within specified tolerances using conversion tables contained in the latest revision of Federal Standard No. 376

22、 and all other requirements of this Commercial Item Description are met. If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch-pound units, a request shall be made to the contracting officer to determine if the product is acceptable. The c

23、ontracting officer has the option of accepting or rejecting the product. 3. Requlatorv Requirements. The offeror/contractor is encouraged to use recoverable materials in accordance with Public Law 94-580 to the maximum extent practicable. 4. Preservation, packaqinq, p ackinq, labelins, and markinq.

24、The preservation, packaging, packing, labeling, and marking shall be as specified in the contract or order. Marking on the TVSS shall include “Suitable For Shipboard Usell. Notes. Purchaser should specify type, cord-length, number of receptacles and if bid samples are required. 1. Orderins data. Pur

25、chaser shall specify the following: (a) Title,.number and date of this commercial item description. (b) CID type (see salient characteristics). (c) Number of receptacles (for cord connected TVSS units; suggested numbers of receptacles are 5, 6 or 7). (d) Cord length (if other than 6-feet; other sugg

26、ested lengths are 9-, 12-, and 15-feet). FED-STD-376 is available from the Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A -A05 Ob 22 9777774 0363528 731 A-A-50622 MILITARY INTERESTS: Military coordinatina activity: O Navy - SH Preparinq activity: (Project 6150-N239) Navy - SH Review activity: DLA - GS 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-