1、METRICA-A-5972826 June 2002COMMERCIAL ITEM DESCRIPTIONPLUG, TUBE FITTING, BLOWN OPTICAL FIBERThe General Services Administration has authorizedthe use of this commercial item description (CID).1. SCOPE. This Commercial Item Description (CID) covers the requirements fora tube fitting plug (TFP) which

2、 is used with a tube fitting / tube coupler toseal the ends of empty blown optical fiber (BOF) tubes in tube routing boxes,fiber optic interconnection boxes and equipment, or is used to seal an unusedport of a tube tee.2. CLASSIFICATION. This CID uses a classification system that is includedin the P

3、art or Identification Number (PIN) as shown in the following example(see 7.2).2.1 Part or Identification Number (PIN).AA59728 -TFP-8CID numberNominal outer diameter of mating plug surface (in mm)3. SALIENT CHARACTERISTICS.3.1 Design, construction and dimensions. Design, construction and dimensionssh

4、all be as specified in figure 1.Beneficial comments (recommendations, additions, deletions) and any pertinentdata which may be of use in improving this document should be sent by letterto: Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull AveSE Stop 5160, Washington Navy Yard, D.C

5、 20376-5160AMSC N/A FSC 6099DISTRIBUTION STATEMENT A: Approved for public release; distribution isunlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-597282 Figure 1. BOF tube fitting plug.Table 1. Tube fitting plug critical diameter dimen

6、sions.PIN dash number A diameter- TFP 8 8 +0.05 mm-0.1 mm3.2 Materials.3.2.1 Polymer materials. The tube fitting plug shall be fabricated from alow toxicity polymer material. Polymer materials shall not be affected bythe use of alcohol based cleaning solutions. Polymer materials shall notdegrade whe

7、n the tube fitting plug is operated under the environmentalconditions defined herein.3.2.2 Metallic materials. Metallic materials shall not be used.3.2.3 Toxic and hazardous products and formulations. The products used inthe tube fitting plug construction shall not give off toxic or explosivefumes w

8、hen exposed to flame. Materials used shall have no adverse effect onthe health of personnel when used for the intended purpose.3.2.4 Fungus. When tested in accordance with TIA/EIA-455-56 for a durationof 28 days, tube fitting plug materials shall show sparse or very restrictedmicrobial growth and re

9、production with minor or inhibited substrateutilization. There shall be little or no chemical, physical, or structuralchange detectable.3.2.5 Flammability. When tested in accordance with UL-94, tube fitting plugmaterials shall have a rating of HB.3.3 Mechanical properties.3.3.1 Tube fitting plug to

10、tube fitting retention. When subjected to anaxial separation force of 67 N (15 lb) for 1 minute, the tube fitting plugshall remain engaged in a tube fitting compliant with CID A-A-59731. Uponvisual examination, there shall be no evidence of physical damage detrimentalto the operation of the tube fit

11、ting plug.18 mmdia max12 mmmaxAdia(see table 1)30 mm maxProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-597283 3.3.2 Tube fitting plug material tensile strength. When tested in accordancewith ASTM D 638, the tube fitting plug material tensile str

12、ength at yieldshall be not less than 50 N/mm2.3.4 Environmental properties.3.4.1 Temperature ranges. The tube fitting plug shall operate over atemperature range from 28 degrees C to +65 degrees C and shall be capable ofwithstanding storage under temperatures from 40 degrees C to +70 degrees C.3.4.2

13、High temperature tube fitting plug to tube coupler retention. Whensubjected to an axial separation force of 67 N (15 lb) for 1 minute at atemperature of +65 degrees C, the tube fitting plug shall remain engaged in atube coupler compliant with CID A-A-59731. Upon visual examination, thereshall be no

14、evidence of physical damage detrimental to the operation of thetube fitting plug. Damage to the tube fitting plug outer diameter due to thetube coupler tube retention mechanism is acceptable.3.4.3 Life aging. When tested for 240 hours at 110 degrees C in accordancewith EIA/TIA-455-4, the tube fittin

15、g plug shall withstand exposure toaccelerated aging conditions. Upon visual examination, there shall be noevidence of deterioration of component parts or materials, physicaldistortion, cracking, separation of bonded surfaces, or other physical damagedetrimental to the operation of the tube fitting p

16、lug unit. After exposure,the tube fitting plug material tensile strength (see 3.3.2) shall be not lessthan 50% of the unaged tensile strength and the tube fitting plug shall meetthe tube fitting plug to tube coupler retention requirements (see 3.3.1).3.4.4 Storage temperature. When tested for 24 hou

17、rs at the low storagetemperature, and 24 hours at the high storage temperature, the tube fittingplug shall withstand exposure to the defined storage temperature extremes.Upon visual examination, there shall be no evidence of physical damagedetrimental to the operation of the tube fitting plug. After

18、 exposure, thetube fitting plug shall meet the dimensional requirements specified in 3.1.3.5 Mass. When measured with scales, the mass of the tube fitting plug shallbe not greater than 5 gms.3.6 Size. When visually inspected in accordance with TIA/EIA-455-13, tubefitting plug dimensions shall be in

19、compliance with figure 1 and table 1.3.7 Marking. When visually inspected, tube fitting plug packages shall bemarked with the manufacturers CAGE code, name, or logo and the tube fittingplug PIN. Alternatively the tube fitting plug packages shall be marked withthe manufacturers CAGE code, name, or lo

20、go and the manufacturers commercialpart number. Markings shall be legible and permanent.3.8 Workmanship. When visually inspected, tube fitting plugs shall be freefrom sharp edges, burrs, rough surfaces or other defects that adverselyaffect performance or appearance.4. REGULATORY REQUIREMENTS.4.1 Rec

21、overed materials. Products provided are encouraged to be manufacturedwith recovered materials to the maximum extent practicable, in accordancewith paragraph 23.403 of the Federal Acquisition Regulation (FAR).Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH

22、S-,-,-A-A-597284 5. QUALITY ASSURANCE PROVISIONS.5.1 Responsibility for inspection. Unless otherwise specified in thecontract or purchase order, the contractor is responsible for the performanceof all inspection, examination, and test requirements specified herein.Except as otherwise specified in th

23、e contract or purchase order, thecontractor may use his own or any other facilities suitable for theinspection requirements specified herein, unless disapproved by theGovernment. The Government reserves the right to perform any of theinspections, examinations, or tests set forth in this description

24、where suchinspections, examinations, and tests are deemed necessary to assure suppliesand services conform to prescribed requirements.5.2 Conformance tests. Tube fitting plugs for delivery under this CID shallbe subjected at a minimum to the following inspections:a. Markingb. Workmanship5.3 Product

25、conformance. The contractor shall certify and maintainobjective quality evidence that the product offered meets the requirements ofthis CID, and that the product conforms to the producers own drawings,specifications, standards, quality assurance practices, and is the same asthe product provided as a

26、 bid sample. The Government reserves the right torequire proof of such conformance prior to the first delivery and thereafteras may be otherwise provided for under the provisions of the contract.5.4 Market acceptability. The item offered must have been sold to thegovernment or commercial market for

27、a minimum of one year.5.5 Certificate of compliance. A certificate of compliance shall accompanyall tube fitting plugs supplied to this CID.6. PACKAGING.6.1 Preservation, packaging, packing, labeling, and marking. Preservation,packaging, labeling, and marking shall be as specified in the contract or

28、purchase order.7. NOTES.7.1 Intended use. Tube fitting plugs in accordance with this CID areintended to be used as specified in MIL-STD-2042 with tube couplers inaccordance with A-A-59731.7.2 PIN. The PIN defined in paragraph 2.1 should be used for Governmentprocurement.7.3 Sources of documents.ASTM

29、 standards are available from the ASTM International, 100 BarrHarbor Drive, West Conshohocken, Pennsylvania, 19428-2959.EIA/TIA standards are available from Electronic Industry Alliance,Engineering Department, 2500 Wilson Boulevard, Suite 300, Arlington,Virginia 22201-3834.Provided by IHSNot for Res

30、aleNo reproduction or networking permitted without license from IHS-,-,-A-A-597285 UL standards are available from the Underwriters Laboratory Inc. 333Pfingsten Road, Northbrook, IL 60062.Federal Government publications are available from the StandardizationDocuments Order Desk, 700 Robbins Avenue,

31、Philadelphia, PA 19120-5094.7.4 Ordering data. The contract or purchase order should specify thefollowing:a. CID number, revision, and CID PIN.b. Quality assurance provisions.c. Packaging requirements.7.5 Storage. Tube fitting plug materials may degrade upon extended exposureto sunlight or other sou

32、rces of ultraviolet radiation. Storage of tubefitting plugs in a dark environment is recommended.7.6 Suggested sources of supply. Suggested sources of supply are listedherein. Additional sources will be added as they become available.CID PIN VendorCAGEVendor commercialPINTBD TBDCustodian: Preparing activity:Navy - SH Navy - SHAir Force - 11Army - CR (Project 6099-0006-003)Review Activities:Air Force - 13, 19, 93, 99Misc - DIProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1