NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf

上传人:proposalcash356 文档编号:978635 上传时间:2019-03-13 格式:PDF 页数:4 大小:24.67KB
下载 相关 举报
NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf_第1页
第1页 / 共4页
NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf_第2页
第2页 / 共4页
NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf_第3页
第3页 / 共4页
NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND MIL-DTL-24643/11E 1 October 2009 SUPERSEDING MIL-DTL-24643/11D 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, 600 VOLTS, TYPE LSSSF This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acqu

2、iring the product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Non-Watertight First - Copper conductor, uncoated, 300 MCM AWG, Class G stranding (see note 1). Second - Separator may be used at manufacturers option where required to provide free-strippin

3、g insulation. Third - Thermoset insulation. Minimum average wall thickness of 0.075 inch. Fourth - Optional reinforcement. Fifth - Cross-linked polyolefin jacket bonded to the underlying insulation. Minimum average wall thickness of 0.075 inch. NOTE: The copper shall be hard drawn, having a minimum

4、tensile strength of 67,200 lb/in, and minimum elongation of 0.85 percent in 60-inch lengths before stranding. The resistance specified is based on 102.7 percent of the values required for annealed bare copper. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted wit

5、hout license from IHS-,-,-MIL-DTL-24643/11E TABLE I. Details. Overall diameter Military part no. M24643/11 Type and size Conductor size min. (inch) max. (inch) -01UN LSSSF-7 300 MCM (Class G) 1.020 1.100 REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/

6、1000 feet at 25 C, max.) 0.0388 Voltage withstand (volts, root mean square, min.) Conductor to ground 2500 Insulation resistance (megohms/1000 feet, min.) Conductor to ground 100 Conductor continuity No failure Group A: Visual and dimensional No failure Group B: Cold bending cable at minus 302 C two

7、 turns around No damage an 8.5“ mandrel Thermoset proof test (percent, max.) Insulation 50Jacket (when tested at 200 C) 50 Drip (951 C) Zero Physicals (unaged) Insulation (extruded) Tensile strength (lb/in2, min.) 700 Elongation (percent, min.) 150 Jacket (cable) Tensile strength (lb/in2, min.) 1300

8、 Elongation (percent, min.) 160 Tear (lb/in thickness, min.) 35 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/11E Group C: Physicals (aged) air oven Insulation (extruded) Tensile strength (percent of unaged, min.) 75 Elongation (per

9、cent of unaged, min.) 75 Jacket (cable) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Permanence of printing (jacket) (cycles, min.) 125 Heat distortion (percent of unaged, max.) 30 Shrinkage No failure Group D: Flame propagation (cable) No failure Qualificati

10、on Inspection: Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following: Aging and compatibility (cable) (1255 C) No failure Abrasion resistance (jacket) (scrapes, min.) 75 Acid gas equivalent (percent, max.) Jacket 2 Insulation 18 Halogen content (percent,

11、 max.) Jacket 0.2 Insulation 0.2Immersion (jacket) Tensile strength (percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index (max.) Jacket 25 Insulation 45Toxicity index (max.) Jacket 5 Insulation 1.5 Durometer (jacket) - Type A (hardness, min.) 80 3 Provided by IHSNot for Re

12、saleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/11E 4 Weathering (jacket) No failure Electrical moisture absorption No failure UNIT ORDERING LENGTHS: Type and size Feet (minimum) Feet (maximum) LSSSF-7 1045 1155 CHANGES FROM PREVIOUS ISSUE: Marginal notations a

13、re not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Army MI Navy SH Navy SH (Project 6145-2008-015) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities listed above were intereste

14、d in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • EN 14809-2005 en Surfaces for sports areas - Determination of vertical deformation (Incorporating corrigendum October 2007)《运动场表面 垂直变形的测定 合并勘误表-2007年10月》.pdf EN 14809-2005 en Surfaces for sports areas - Determination of vertical deformation (Incorporating corrigendum October 2007)《运动场表面 垂直变形的测定 合并勘误表-2007年10月》.pdf
  • EN 14810-2006 en Surfaces for sports areas - Determination of spike resistance《运动场表面 鞋钉阻力的测定》.pdf EN 14810-2006 en Surfaces for sports areas - Determination of spike resistance《运动场表面 鞋钉阻力的测定》.pdf
  • EN 14811-2006 en Railway applications - Track - Special purpose rail - Grooved and associated construction (Incorporates Amendment A1 2009)《轨道交通 轨道 专用钢轨 凹槽和相关设施 包含修改件2009》.pdf EN 14811-2006 en Railway applications - Track - Special purpose rail - Grooved and associated construction (Incorporates Amendment A1 2009)《轨道交通 轨道 专用钢轨 凹槽和相关设施 包含修改件2009》.pdf
  • EN 14812-2005 en Water conditioning equipment inside buildings - Chemical dosing systems - Pre-set dosing systems - Requirements for performance safety and testing (Incorporates Am.pdf EN 14812-2005 en Water conditioning equipment inside buildings - Chemical dosing systems - Pre-set dosing systems - Requirements for performance safety and testing (Incorporates Am.pdf
  • EN 14813-1-2006 en Railway applications - Air conditioning for driving cabs - Part 1 Comfort parameters (Incorporates Amendment A1 2010)《轨道交通 机车驾驶室用空调 第1部分 舒适参数》.pdf EN 14813-1-2006 en Railway applications - Air conditioning for driving cabs - Part 1 Comfort parameters (Incorporates Amendment A1 2010)《轨道交通 机车驾驶室用空调 第1部分 舒适参数》.pdf
  • EN 14813-2-2006 en Railway applications - Air conditioning for driving cabs - Part 2 Type tests (Incorporates Amendment A1 2010)《轨道交通 机车驾驶室用空调 第2部分 类型试验》.pdf EN 14813-2-2006 en Railway applications - Air conditioning for driving cabs - Part 2 Type tests (Incorporates Amendment A1 2010)《轨道交通 机车驾驶室用空调 第2部分 类型试验》.pdf
  • EN 14814-2007 4372 Adhesives for thermoplastic piping systems for fluids under pressure - Specifications《压力下流体用热塑性管道系统的粘合剂 规范》.pdf EN 14814-2007 4372 Adhesives for thermoplastic piping systems for fluids under pressure - Specifications《压力下流体用热塑性管道系统的粘合剂 规范》.pdf
  • EN 14814-2016 en Adhesives for thermoplastic piping systems for fluids under pressure - Specifications《压力下流体用热塑性管道系统的粘合剂-规范》.pdf EN 14814-2016 en Adhesives for thermoplastic piping systems for fluids under pressure - Specifications《压力下流体用热塑性管道系统的粘合剂-规范》.pdf
  • EN 14817-2006 en Railway applications - Suspension components - Air spring control elements《轨道交通 悬架元部件 空气弹簧控制元素》.pdf EN 14817-2006 en Railway applications - Suspension components - Air spring control elements《轨道交通 悬架元部件 空气弹簧控制元素》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1