NAVY MIL-DTL-7793 16 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC SQUARE.pdf

上传人:hopesteam270 文档编号:978871 上传时间:2019-03-13 格式:PDF 页数:5 大小:77.40KB
下载 相关 举报
NAVY MIL-DTL-7793 16 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC SQUARE.pdf_第1页
第1页 / 共5页
NAVY MIL-DTL-7793 16 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC SQUARE.pdf_第2页
第2页 / 共5页
NAVY MIL-DTL-7793 16 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC SQUARE.pdf_第3页
第3页 / 共5页
NAVY MIL-DTL-7793 16 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC SQUARE.pdf_第4页
第4页 / 共5页
NAVY MIL-DTL-7793 16 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC SQUARE.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/16A 19 October 2012 SUPERSEDING MIL-M-7793/16 15 December 1988 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 5 VDC, SQUARE This specification is approved for use by all Departments and Agencies of the Department of Defense. Reactivat

2、ed after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. M7793/16-1. Provided by IHSNot for ResaleNo reproduction or networking permitted w

3、ithout license from IHS-,-,-MIL-DTL-7793/16A 2 REQUIREMENTS: 1. Dimensions. Dimensions and configuration shall be in accordance with Figure 1. All dimensions are in inches. Unless otherwise specified, tolerances are .02 for two-place decimals and 0.015 for three-place decimals. 2. Mounting flange. T

4、he mounting flange, threaded extension and threaded protection cap shall be constructed of aluminum alloy with an olive drab chromate coating over cadmium plating. 3. Protection cap. The protection cap shall be in accordance with MS25043-10DA per SAE-AS25043 except for the finish and the means of at

5、tachment. The finish shall be in accordance with Requirement 2 and the metallic chain shall be replaced with a nylon lanyard. 4. Contacts. The contacts shall meet all the requirements of silver plated solder contacts from SAE-AS50151. PERFORMANCE REQUIREMENTS: 1. Dielectric strength. The meter shall

6、 be capable of withstanding the application of 600 VRMS (room) and 350 VRMS (altitude) between the terminals and the case. 2. Life accuracy. Life accuracy shall be 0.1% from -65 C to +125 C and 4.5 to 10 VDC. 3. Power consumption. Power consumption at 5 VDC shall not exceed 2 milliwatts. 4. Ripple v

7、oltage. The meter shall operate normally when subjected to a 2 volt peak (4 volts peak-to-peak) ripple between 10 Hz and 10 KHz superimposed on 7.0 VDC. 5. Operating temperature range. The operating temperature range shall be from -65 C to +125 C. 6. Part number. The part number shall be M7793/16-1.

8、 7. Time range. Total readout of the meters shall be 99999.99 hours. 8. Meter output. The output from the meter shall be in a serial binary coded decimal format. The output impedance shall be 100K 10%. A logical “zero” shall be between 0.0 and +0.2 volt. A logical “one” shall be between +3.3 and +6.

9、6 volts. The output pin assignments are shown on figure 2 and the output data format is shown on figure 3. 9. Transient protection. No temporary or permanent degradation shall be produced in the meter when subjected to 25 volt transients of 10 microsecond duration occurring at a 1 millisecond repeti

10、tion rate. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/16A 3 10. Durability of cap and threads. No mechanical or electrical degradation after 100 cycles in accordance with SAE-AS50151. 11. Operating voltage range. The operating volta

11、ge range shall be from 4.5 to 10 VDC. 12. Durability of connectors and contacts. No mechanical or electrical degradation after 100 cycles in accordance with SAE-AS50151. Operational accuracy shall be checked at the end of the test. 13. Weight. The weight shall be not greater than 1.0 ounce with the

12、attached protection cap. 14. Tensile strength of lanyard. The lanyard shall withstand a tensile load of 25 pounds when applied to Axis “A” and Axis “B” as shown on figure 1. 15. Qualification tests. Qualification tests will be conducted in accordance with MIL-DTL-7793, except that the voltage, tempe

13、rature and accuracy shall be as specified herein. Salt spray, moisture resistance, vibration, shock, electromagnetic compatibility and low temperature storage shall be conducted with the protective cap in place. Hermetic seal test is not applicable. NOTES. 1. Elapsed time is read from the M7793/16-1

14、 meter by mating the M7793/16-1 meters connector with the M7793/12-1 readers connector and operating the reader. 2. Digital readout and meter face plate per MIL-DTL-7793 are not applicable since the digital readout is provided by the separate M7793/12-1 reader. 3. The meter is designed to have an el

15、ectrical ground and a continuous EMI/RFI shield with the threaded protection cap in place. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/16A 4 FIGURE 2. Readout pin assignment. FIGURE 3. Output data format. Provided by IHSNot for Resal

16、eNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/16A 5 Referenced documents. In addition to MIL-DTL-7793, this specification sheet references SAE-AS50151 and SAE-AS25043. 8. Changes from previous issue. Marginal notations are not used in this revision to identify ch

17、anges with respect to the previous issue due to the extent of the changes. Custodians: Preparing activity: Army - MI Navy - AS Navy - AS (Project 6645-2012-018) Air Force - 99 Review activities: Navy OS, SH DLA GS1 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS EN 60534-5-2004 Industrial-process control valves - Marking《工业过程控制阀 标记》.pdf BS EN 60534-5-2004 Industrial-process control valves - Marking《工业过程控制阀 标记》.pdf
  • BS EN 60534-6-1-1998 Industrial-process control valves - Mounting details for attachment of positioners to control valves - Positioner mounting on linear actuators《工业过程控制阀 控制阀位置控制器.pdf BS EN 60534-6-1-1998 Industrial-process control valves - Mounting details for attachment of positioners to control valves - Positioner mounting on linear actuators《工业过程控制阀 控制阀位置控制器.pdf
  • BS EN 60534-6-2-2001 Industrial-process control valves - Mounting details for attachment of positioners to control valves - Positioner mounting on rotary actuators - Positioner mou.pdf BS EN 60534-6-2-2001 Industrial-process control valves - Mounting details for attachment of positioners to control valves - Positioner mounting on rotary actuators - Positioner mou.pdf
  • BS EN 60534-7-2010 Industrial-process control valves Control valve data sheet《工业过程控制阀 控制阀数据表》.pdf BS EN 60534-7-2010 Industrial-process control valves Control valve data sheet《工业过程控制阀 控制阀数据表》.pdf
  • BS EN 60534-8-1-2005 Industrial-process control valves - Part 8-1 Noise considerations - Laboratory measurement of noise generated by aerodynamic flow through control valves《工业过程控制.pdf BS EN 60534-8-1-2005 Industrial-process control valves - Part 8-1 Noise considerations - Laboratory measurement of noise generated by aerodynamic flow through control valves《工业过程控制.pdf
  • BS EN 60534-8-2-2011 Industrial-process control valves Noise considerations Laboratory measurement of noise generated by hydrodynamic flow through control valves《工业过程控制阀 流动液流经控制阀产生.pdf BS EN 60534-8-2-2011 Industrial-process control valves Noise considerations Laboratory measurement of noise generated by hydrodynamic flow through control valves《工业过程控制阀 流动液流经控制阀产生.pdf
  • BS EN 60534-8-3-2011 Industrial-process control valves Noise considerations Control valve aerodynamic noise prediction method《工业过程控制阀 噪声问题 控制阀的气动噪声预测法》.pdf BS EN 60534-8-3-2011 Industrial-process control valves Noise considerations Control valve aerodynamic noise prediction method《工业过程控制阀 噪声问题 控制阀的气动噪声预测法》.pdf
  • BS EN 60534-9-2007 Industrial-process control valves - Test procedure for response measurements from step inputs《工业过程控制阀 阶跃输入反应测量的试验程序》.pdf BS EN 60534-9-2007 Industrial-process control valves - Test procedure for response measurements from step inputs《工业过程控制阀 阶跃输入反应测量的试验程序》.pdf
  • BS EN 60539-1-2016 Directly heated negative temperature coefficient thermistors Generic specification《直接加热负温度系数电热调节器 通用规范》.pdf BS EN 60539-1-2016 Directly heated negative temperature coefficient thermistors Generic specification《直接加热负温度系数电热调节器 通用规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1