1、*USACE / NAVFAC / AFCESA / NASA UFGS-02 82 33.13 20 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-02 82 33.13 20 (February 2010)UFGS-02 82 33.13 20 (April 2006)UFGS-13283 (February 2002) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION T

2、ABLE OF CONTENTSDIVISION 02 - EXISTING CONDITIONSSECTION 02 82 33.13 20REMOVAL/CONTROL AND DISPOSAL OF PAINT WITH LEAD08/11PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.2.1 Abatement1.2.2 Action Level1.2.3 Area Sampling1.2.4 Child Occupied Facility1.2.5 Competent Person (CP)1.2.6 Contaminated Room1.2

3、.7 Decontamination Shower Facility1.2.8 Deleading1.2.9 Eight-Hour Time Weighted Average (TWA)1.2.10 High Efficiency Particulate Air (HEPA) Filter Equipment1.2.11 Lead1.2.12 Lead-Based Paint (LBP)1.2.13 Lead-Based Paint Activities1.2.14 Lead-Based Paint Hazard (LBP Hazard)1.2.15 Paint with Lead (PWL)

4、1.2.16 Lead Control Area1.2.17 Lead Permissible Exposure Limit (PEL)1.2.18 Personal Sampling1.2.19 Physical Boundary1.2.20 Target Housing1.3 DESCRIPTION1.3.1 Description of Work1.3.2 Coordination with Other Work1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Qualifications1.5.1.1 Qualifications of CP1.5.1.

5、2 Training Certification1.5.1.3 Testing Laboratory1.5.1.4 Third Party Consultant QualificationsSECTION 02 82 33.13 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.5.2 Requirements1.5.2.1 Competent Person (CP) Responsibilities1.5.2.2 Lead-B

6、ased Paint/Paint with Lead Removal/Control Plan (LBP/PWL R/CP)1.5.2.3 Occupational and Environmental Assessment Data Report1.5.2.4 Medical Examinations1.5.2.5 Training1.5.2.6 Respiratory Protection Program1.5.2.7 Hazard Communication Program1.5.2.8 Lead Waste Management1.5.2.9 Environmental, Safety

7、and Health Compliance1.5.3 Pre-Construction Conference1.6 EQUIPMENT1.6.1 Respirators1.6.2 Special Protective Clothing1.6.3 Rental Equipment Notification1.6.4 Vacuum Filters1.6.5 Equipment for Government Personnel1.7 PROJECT/SITE CONDITIONS1.7.1 Protection of Existing Work to RemainPART 2 PRODUCTSPAR

8、T 3 EXECUTION3.1 PREPARATION3.1.1 Protection3.1.1.1 Notification3.1.1.2 Boundary Requirements3.1.1.3 Furnishings3.1.1.4 Heating, Ventilating and Air Conditioning (HVAC) Systems3.1.1.5 Decontamination Shower Facility3.1.1.6 Eye Wash Station3.1.1.7 Mechanical Ventilation System3.1.1.8 Personnel Protec

9、tion3.2 ERECTION3.2.1 Lead Control Area Requirements3.3 APPLICATION3.3.1 Work Procedures3.3.2 Lead-Based Paint Removal/Control/Deleading3.3.2.1 Indoor Paint Removal3.3.2.2 Outdoor Paint Removal3.3.3 Personnel Exiting Procedures3.4 FIELD QUALITY CONTROL3.4.1 Tests3.4.1.1 Air and Wipe Sampling3.4.1.2

10、Air Sampling During Paint Removal Work3.4.1.3 Sampling After Paint Removal/Control3.4.1.4 Testing of Removed Paint and Used Abrasive3.5 CLEANING AND DISPOSAL3.5.1 Cleanup3.5.1.1 Clearance Certification3.5.2 Disposal3.5.2.1 Disposal Documentation3.5.3 Payment for Hazardous Waste- End of Section Table

11、 of Contents -SECTION 02 82 33.13 20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-02 82 33.13 20 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-02 82 33.13 20 (February 2010)UFGS-02 82 33.13 20

12、(April 2006)UFGS-13283 (February 2002) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 02 82 33.13 20REMOVAL/CONTROL AND DISPOSAL OF PAINT WITH LEAD08/11*NOTE: This guide specification covers the requirements for for limiting occupational and envi

13、ronmental exposure to lead when removing/controlling lead-based paint or paint with lead (LBP/PWL).Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specificatio

14、n for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommend

15、ed changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: This guide specification is intended for use in projects where LBP/PWL must be removed/controlled (including paint film stabilization) or lead-based paint hazards abated as defined b

16、y Public Law 102-550 Title X - Residential Lead-Based Paint Hazard Reduction Act of 1992. Local requirements may be substantially restrictive for the conduction of LBP or LBP hazard abatement projects.*NOTE: This guide specification should be used with all of the requirements of 40 CFR 745 (or state

17、/local requirements in states with authorized SECTION 02 82 33.13 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-programs) for projects involving lead-based paint hazard abatement in target housing and child occupied facilities being transf

18、erred or resolving facility-related work due to an occupant child with an elevated blood lead. In these projects, it is required that the specification editor has appropriate training regarding lead-based paint activities. Certification as a project designer per 40 CFR 745 is required. *NOTE: Where

19、LBP/PWL is not specifically being removed/controlled as a hazard abatement action or deleading, use Section 02 83 13.00 20 LEAD IN CONSTRUCTION.*NOTE: The classification of the lead-based paint or paint with lead as hazardous waste must be performed in accordance with 40 CFR 261, and in the design p

20、hase of the project. This classification is prerequisite to the requirement of special handling, storage, and disposal according to Federal, state and local hazardous waste management regulations. *NOTE: When historic preservation work will remove LBP/PWL, refer to the Secretary of the Interiors Sta

21、ndards for the Treatment of Historic Properties and/or Brief 37, “Appropriate Methods for Reducing Lead-Paint Hazards in Historic Housing“ as appropriate. *NOTE: Projects involving housing improvement, maintenance, or repair are not considered a lead-based paint hazard abatement action even if the e

22、ffect of the work removes (or controls) lead exposure potentials to the occupants. However, appropriate precautions for protecting occupants and leaving the housing clean (clearance) after concluding any work disturbing paint with lead must be considered. Specific training and certification requirem

23、ents (40 CFR 745 or authorized state program requirements) may not be necessary for all projects. However, it is strongly recommended that the specification editor have appropriate training regarding lead-based paint. *NOTE: Obtain from the activity information on lead-based paint/paint with lead to

24、 be removed by the project. *SECTION 02 82 33.13 20 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*NOTE: Projects that involve cutting, sawing, sanding, scraping, needle gunning, abrasive blasting, high temperature removal, etc., of lead-base

25、d paint/paint with lead materials may result in lead exposures in excess of OSHA limits. Therefore, personal protective equipment should be used and controls implemented. Institute worker protection controls as indicated in 29 CFR 1926.62 and herein. Also, some work practices are prohibited for LBP/

26、LBP hazard abatement (e.g., machine sanding, abrasive blasting) unless used with HEPA exhaust controls (see 40 CFR 745.227). *NOTE: Drawings should indicate the location, extent and condition of the LBP/PWL to be removed/controlled. Clearly indicate if the LBP/PWL is to be removed to the substrate.

27、*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizard

28、s Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from th

29、is section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN INDUSTRIAL H

30、YGIENE ASSOCIATION (AIHA)AIHA Z88.6 (2006) Respiratory Protection - Respirator Use-Physical Qualifications for PersonnelSECTION 02 82 33.13 20 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-U.S. DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT (HUD

31、)HUD 6780 (1995; Errata Aug 1996;Rev Ch. 7 - 1997) Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in HousingU.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)29 CFR 1926.103 Respiratory Protection29 CFR 1926.21 Safety Training and Education29 CFR 1926.33 Access to Employ

32、ee Exposure and Medical Records29 CFR 1926.55 Gases, Vapors, Fumes, Dusts, and Mists29 CFR 1926.59 Hazard Communication29 CFR 1926.62 Lead29 CFR 1926.65 Hazardous Waste Operations and Emergency Response40 CFR 260 Hazardous Waste Management System: General40 CFR 261 Identification and Listing of Haza

33、rdous Waste40 CFR 262 Standards Applicable to Generators of Hazardous Waste40 CFR 263 Standards Applicable to Transporters of Hazardous Waste40 CFR 264 Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities40 CFR 265 Interim Status Standards for Owners and

34、Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities40 CFR 268 Land Disposal Restrictions40 CFR 745 Lead-Based Paint Poisoning Prevention in Certain Residential Structures49 CFR 172 Hazardous Materials Table, Special Provisions, Hazardous Materials Communications, Emergency Respo

35、nse Information, and Training Requirements49 CFR 178 Specifications for PackagingsUNDERWRITERS LABORATORIES (UL)UL 586 (2009) Standard for High-Efficiency Particulate, Air Filter UnitsSECTION 02 82 33.13 20 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr

36、om IHS-,-,-1.2 DEFINITIONS1.2.1 AbatementAs applied to target housing and child occupied facilities, “abatement“ means any set of measures designed to permanently eliminate lead-based paint hazards in accordance with standards established by appropriate Federal agencies. Such term includes:a. The re

37、moval of lead-based paint and lead-contaminated dust, the permanent containment or encapsulation of lead-based paint, the replacement of lead-painted surfaces or fixtures, and the removal or covering of lead contaminated soil; andb. All preparation, cleanup, disposal, and post-abatement clearance te

38、sting activities associated with such measures.1.2.2 Action LevelEmployee exposure, without regard to use of respirators, to an airborne concentration of lead of 30 micrograms per cubic meter of air averaged over an 8 hour period in a work environment.1.2.3 Area SamplingSampling of lead concentratio

39、ns within the lead control area and inside the physical boundaries, which is representative of the airborne lead concentrations but is not collected in the breathing zone of personnel.1.2.4 Child Occupied FacilityA building or portion of a building constructed prior to 1978 visited regularly by the

40、same child, 6 years of age or under, on a least two different days within any week, provided each days visit last at least 3 hours and the combined weekly visit last at least 6 hours and the combined annual visit last at least 60 hours. Child occupied facilities may include, but are not limited to d

41、ay-care centers, preschools and kindergarten classrooms.1.2.5 Competent Person (CP)As used in this section, refers to a person employed by the Contractor who is trained in the recognition and control of lead hazards in accordance with current federal, State, and local regulations. A Certified Indust

42、rial Hygienist (CIH) certified for comprehensive practice by the American Board of Industrial Hygiene or a Certified Safety Professional (CSP) certified by the Board of Certified Safety Professionals is the best choice.1.2.6 Contaminated RoomRefers to a room for removal of contaminated personal protective equipment (PPE).1.2.7 Decontamination Shower FacilityThat facility that encompasses a clean clothing storage room, and a conta

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1