1、*USACE / NAVFAC / AFCESA UFGS-08 11 13 (February 2010)-Preparing Activity: NAVFAC Superseding UFGS-08 11 13 (August 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 11 13STEEL DOORS AND FRAMES

2、02/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 STANDARD STEEL DOORS2.1.1 Classification - Level, Performance, Model2.1.1.1 Standard Duty Doors2.1.1.2 Heavy Duty Doors2.1.1.3 Extra Heavy Duty Doors2.1.1.4 Maximum Duty Doors2.2 CUSTOM HOLLOW METAL

3、DOORS2.3 INSULATED STEEL DOOR SYSTEMS2.4 SOUND RATED STEEL DOORS2.5 ACCESSORIES2.5.1 Shelves for Dutch Doors2.5.2 Louvers2.5.2.1 Interior Louvers2.5.2.2 Exterior Louvers2.5.3 Astragals2.5.4 Moldings2.6 INSULATION CORES2.7 STANDARD STEEL FRAMES2.7.1 Welded Frames2.7.2 Knock-Down Frames2.7.3 Mullions

4、and Transom Bars2.7.4 Stops and Beads2.7.5 Terminated Stops2.7.6 Cased Openings2.7.7 Anchors2.7.7.1 Wall Anchors2.7.7.2 Floor Anchors2.8 FIRE AND SMOKE DOORS AND FRAMESSECTION 08 11 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.8.1 Label

5、s2.8.2 Oversized Doors2.8.3 Astragal on Fire and Smoke Doors2.9 WEATHERSTRIPPING2.9.1 Integral Gasket2.10 HARDWARE PREPARATION2.11 FINISHES2.11.1 Factory-Primed Finish2.11.2 Hot-Dip Zinc-Coated and Factory-Primed Finish2.11.3 Electrolytic Zinc-Coated Anchors and Accessories2.11.4 Factory-Applied Ena

6、mel Finish2.12 FABRICATION AND WORKMANSHIP2.12.1 Grouted Frames2.13 PROVISIONS FOR GLAZINGPART 3 EXECUTION3.1 INSTALLATION3.1.1 Frames3.1.2 Doors3.1.3 Fire and Smoke Doors and Frames3.2 PROTECTION3.3 CLEANING3.4 SCHEDULE- End of Section Table of Contents -SECTION 08 11 13 Page 2Provided by IHSNot fo

7、r ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA UFGS-08 11 13 (February 2010)-Preparing Activity: NAVFAC Superseding UFGS-08 11 13 (August 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION

8、08 11 13STEEL DOORS AND FRAMES02/10*NOTE: This guide specification covers steel doors and frames. Some paragraphs may need to be supplemented to meet project requirements.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choos

9、e applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestion on this specification are welcome and should be directed to the technical proponent of the specification. A list

10、ing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: On the drawings, show:1. Sizes of door openings, thicknesses of doors, swings, and travels of doo

11、rs, and design of doors, whether flush panel, full flush, paneled, glazed, or louvered. It is recommended that standard door-type nomenclature, SDI 106, be used to indicate designs (e.g., F, L, G, GL, etc., in lieu of A, B, C, etc.).2. Details of nonstructural mullions, mullion covers, and removable

12、 mullions.3. Type and thickness of glazing required; whether or not insulating glass units are required.SECTION 08 11 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4. Method, type, and spacing required for anchoring door frames to adjoinin

13、g construction.5. Lintels and reinforcement required to support walls or partitions above doors.6. Type of shop finish on steel surfaces.7. Free area for louvers in doors.8. Complete door schedule. Schedule should assign a separate number for each opening and should indicate door type and style, mat

14、erial, design, size, thickness, glazed or unglazed, class fire rating for fire doors, hardware set number, threshold material, if any, and material for frames, mullions, and transom bars.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guid

15、e specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the

16、 reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The

17、 publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only.AMERICAN WELDING SOCIETY (AWS)AWS D1.1/D1.1M (2008; Errata 2008) Structural Welding Code - SteelASTM INTERNATIONAL (ASTM)ASTM A 653/A 653M

18、 (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessSECTION 08 11 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM A 879/A 879M (2006) Standard Specific

19、ation for Steel Sheet, zinc Coated by the Electrolytic Process for Applications Requiring Designation of the Coating Mass on Each SurfaceASTM A 924/A 924M (2009a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip ProcessASTM C 578 (2009e1) Standard Speci

20、fication for Rigid, Cellular Polystyrene Thermal InsulationASTM C 591 (2009) Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal InsulationASTM C 612 (2009) Mineral Fiber Block and Board Thermal InsulationASTM D 2863 (2009) Measuring the Minimum Oxygen Concentration

21、to Support Candle-Like Combustion of Plastics (Oxygen Index)ASTM E 1300 (2009a) Determining Load Resistance of Glass in BuildingsASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the SpecimenASTM F 224

22、8 (2009) Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated GlassBUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)ANSI/BHMA A156.115 (2006) Hardware Preparation in Steel Doors and Steel FramesNATIONAL ASSOCIATION OF

23、ARCHITECTURAL METAL MANUFACTURERS (NAAMM)NAAMM HMMA HMM (1999; R2000) Hollow Metal ManualNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 105 (2010) Standard for Installation of Smoke Door Assemblies and Other Opening ProtectivesNFPA 252 (2008) Standard Methods of Fire Tests of Door AssembliesNFPA 80

24、 (2010; Am 10-1) Standard for Fire Doors and Other Opening ProtectivesSECTION 08 11 13 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STEEL DOOR INSTITUTE (SDI/DOOR)SDI/DOOR 111 (2009) Recommended Selection and Usage Guide for Standard Steel D

25、oors, Frames and AccessoriesSDI/DOOR 113 (2001; R2006) Standard Practice for Determining the Steady State Thermal Transmittance of Steel Door and Frame AssembliesSDI/DOOR A250.11 (2001) Recommended Erection Instructions for Steel FramesSDI/DOOR A250.3 (2007) Test Procedure and Acceptance Criteria fo

26、r Factory Applied Finish Painted Steel Surfaces for Steel Doors and FramesSDI/DOOR A250.4 (2001) Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors and Frame AssembliesSDI/DOOR A250.6 (2003; R2009) Recommended Practice for Hardware Reinforcing on Standard Steel Doors and F

27、ramesSDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and FramesUNDERWRITERS LABORATORIES (UL)UL 10C (2009) Standard for Positive Pressure Fire Tests of Door Assemblies1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PR

28、OCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked

29、with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army project

30、s, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for SECTION 08 11 13 Page 6Provided by IHSNot for ResaleNo reproduction or network

31、ing permitted without license from IHS-,-,-Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force

32、, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval

33、.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:*NOTE: When weatherstripping is specified in Section 08 71

34、00 FINISH HARDWARE delete the bracketed item “Weatherstripping“.*SD-02 Shop DrawingsDoors; G; G, _Frames; G; G, _AccessoriesWeatherstrippingShow elevations, construction details, metal gages, hardware provisions, method of glazing, and installation details.Schedule of doors; G; G, _Schedule of frame

35、s; G; G, _Submit door and frame locations.*NOTE: When weatherstripping is specified in Section 08 71 00 FINISH HARDWARE delete the bracketed item “Weatherstripping“.*SD-03 Product DataDoors; G; G, _Frames; G; G, _AccessoriesWeatherstrippingSECTION 08 11 13 Page 7Provided by IHSNot for ResaleNo repro

36、duction or networking permitted without license from IHS-,-,-Submit manufacturers descriptive literature for doors, frames, and accessories. Include data and details on door construction, panel (internal) reinforcement, insulation, and door edge construction. When “custom hollow metal doors“ are pro

37、vided in lieu of “standard steel doors,“ provide additional details and data sufficient for comparison to SDI/DOOR A250.8 requirements. SD-04 SamplesFactory-applied enamel finish; G; G, _Where colors are not indicated, submit manufacturers standard colors and patterns for selection.1.3 DELIVERY, STO

38、RAGE, AND HANDLINGDeliver doors, frames, and accessories undamaged and with protective wrappings or packaging. Strap knock-down frames in bundles. Provide temporary steel spreaders securely fastened to the bottom of each welded frame. Store doors and frames on platforms under cover in clean, dry, ve

39、ntilated, and accessible locations, with 6 mm 1/4 inch airspace between doors. Remove damp or wet packaging immediately and wipe affected surfaces dry. Replace damaged materials with new.PART 2 PRODUCTS2.1 STANDARD STEEL DOORS*NOTE: Include the bracket option below regarding exterior glazing when pe

40、rsonnel density is greater than one person per 40 square meters430 square feet and the minimum AT/FP standoff distances are met. This does not include guard type facilities, single and duplex detached family housing. These requirements are specified in UFC 4-010-01 “DoD Minimum Antiterrorism Standar

41、ds for Buildings“.*SDI/DOOR A250.8, except as specified otherwise. Prepare doors to receive door hardware as specified in Section 08 71 00. Undercut where indicated. Exterior doors shall have top edge closed flush and sealed to prevent water intrusion. Doors shall be 44.5 mm 1-3/4 inch thick, unless

42、 otherwise indicated. Provide exterior glazing in accordance with ASTM F 2248 and ASTM E 1300.2.1.1 Classification - Level, Performance, Model*NOTE: When a door level is not required, delete the entire paragraph for that level. Door levels for various locations should be determined in accordance wit

43、h the following list and sound judgment.Closet doors (without locks) Level 1Individual offices, storage rooms,classrooms, patients rooms,bathrooms, and bedrooms (exceptSECTION 08 11 13 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BEQ bedrooms) Level 2BEQ sleeping room entrance doors and interior egress doors Level 3Exterior Main entrance and circulation doors and other locations Level 4Model designations are