NAVY UFGS-32 84 24-2011 IRRIGATION SPRINKLER SYSTEMS《灌溉洒水器系统》.pdf

上传人:lawfemale396 文档编号:984851 上传时间:2019-03-12 格式:PDF 页数:36 大小:124.26KB
下载 相关 举报
NAVY UFGS-32 84 24-2011 IRRIGATION SPRINKLER SYSTEMS《灌溉洒水器系统》.pdf_第1页
第1页 / 共36页
NAVY UFGS-32 84 24-2011 IRRIGATION SPRINKLER SYSTEMS《灌溉洒水器系统》.pdf_第2页
第2页 / 共36页
NAVY UFGS-32 84 24-2011 IRRIGATION SPRINKLER SYSTEMS《灌溉洒水器系统》.pdf_第3页
第3页 / 共36页
NAVY UFGS-32 84 24-2011 IRRIGATION SPRINKLER SYSTEMS《灌溉洒水器系统》.pdf_第4页
第4页 / 共36页
NAVY UFGS-32 84 24-2011 IRRIGATION SPRINKLER SYSTEMS《灌溉洒水器系统》.pdf_第5页
第5页 / 共36页
点击查看更多>>
资源描述

1、*USACE / NAVFAC / AFCESA / NASA UFGS-32 84 24 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-32 84 24 (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 32 - EXTERIOR IMPROVEMENTSSECTION 32 84 24IRRIGATI

2、ON SPRINKLER SYSTEMS08/11PART 1 GENERAL1.1 REFERENCES1.2 RELATED REQUIREMENTS1.3 SYSTEM DESCRIPTION1.4 SUBMITTALS1.5 DELIVERY, STORAGE, AND HANDLING1.5.1 Delivery1.5.2 Storage1.5.3 Handling1.6 EXTRA STOCK1.7 QUALITY ASSURANCE1.7.1 Required TestPART 2 PRODUCTS2.1 PIPING MATERIALS2.1.1 Copper Tubing a

3、nd Associated Fittings2.1.1.1 Tubing2.1.1.2 Fittings2.1.2 Red Brass Pipe and Associated Fittings2.1.2.1 Pipe2.1.2.2 Fittings2.1.3 Galvanized Steel Pipe and Associated Fittings2.1.3.1 Pipe2.1.3.2 Fittings2.1.4 Polyvinyl Chloride (PVC) Pipe, Fittings and Solvent Cement2.1.4.1 Pipe2.1.4.2 Fittings2.1.4

4、.3 Solvent Cement2.1.5 Polyethylene (PE) Plastic Piping2.1.5.1 Pipe2.1.5.2 Fittings2.1.6 Dielectric Fittings2.1.7 Drip Irrigation Tubing2.1.8 Pipe SleevingSECTION 32 84 24 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.2 IRRIGATION AND DRIP

5、SPRINKLER HEADS2.2.1 Fixed Riser Irrigation Heads2.2.1.1 Stream Rotors, Full or Part Circle2.2.1.2 Gear Rotor Irrigation Head, Full or Part Circle2.2.1.3 Impact Irrigation Head2.2.1.4 Spray Irrigation Heads, Full or Part Circle2.2.1.5 Adjustable Flood Bubbler Head2.2.1.6 Pressure Compensating Flood

6、Bubbler Head2.2.2 Pop-Up Irrigation Head2.2.2.1 Stream Rotor Irrigation Head, Full or Part Circle2.2.2.2 Gear Rotor Irrigation Head, Full or Part Circle2.2.2.3 Impact Irrigation Head2.2.2.4 Spray Irrigation Head, Full or Part Circle2.2.3 Bubbler Irrigation Head2.2.3.1 Adjustable Flood Bubbler2.2.3.2

7、 Pressure Compensating Flood Bubbler2.2.4 Fixed Drip Head2.2.4.1 Multi-Port Outlet Device2.2.4.2 Single Outlet Pressure Compensating Emission Device2.2.4.3 Microspray Device2.2.4.4 In-Line Tubing Device2.2.5 Pop-Up Drip Head2.3 VALVES2.3.1 Isolation Valve2.3.1.1 Ball Valves, Less than 75 mm 3 Inches

8、2.3.1.2 Gate Valves, 75 mm 3 Inches and Larger2.3.2 Control Valves2.3.2.1 Pressure Regulating Master Control Valve2.3.2.2 Remote Control Valve, Electrical2.3.2.3 Manual Angle Control Valve, Manual Globe Control Valve2.3.3 Quick Coupling Valves2.3.4 Hose Bib2.3.5 Drain Valves2.3.5.1 Manual2.3.5.2 Aut

9、omatic2.3.6 Backflow Preventers2.3.6.1 Reduced Pressure Type Backflow Preventers2.3.6.2 Pressure Type Vacuum Breaker2.3.6.3 Atmospheric Vacuum Breaker2.4 ACCESSORIES AND APPURTENANCES2.4.1 Tapping Tee2.4.2 Water Meter2.4.3 Drip Head Accessories2.4.3.1 Strainer2.4.3.2 Riser Adapters2.4.3.3 Tubing Sta

10、kes2.4.3.4 Bug Cap2.4.3.5 Subterranean Drip Box and Cover2.4.3.6 Line Flushing Valve2.4.3.7 Valve Boxes2.4.4 Backflow Preventer Accessories2.4.4.1 Pressure Gages2.4.4.2 Water Hammer Arresters2.4.4.3 Backflow Preventer Enclosure2.4.4.4 Concrete Pads2.4.5 Moisture Sensing Device2.4.5.1 Automatic Rain

11、Shut-Off Device2.4.5.2 Automatic Freeze Shut-Off Device2.4.5.3 Soil Moisture Sensor DeviceSECTION 32 84 24 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.4.6 Air/Vacuum Relief2.4.7 Water Booster Package2.4.7.1 Pump2.4.7.2 Motor2.4.7.3 Piping

12、 and Fittings2.4.7.4 Gages2.4.7.5 Butterfly Valve2.4.7.6 Check Valves2.4.7.7 Pump Control Panels2.4.8 Flow Meter2.5 Automatic Controller Electrical Solar Battery2.5.1 Controller Features2.6 ELECTRICAL CIRCUITS2.6.1 Control Wiring for Electrically Operated Valves2.6.2 Conduit2.7 CONCRETE MATERIALSPAR

13、T 3 EXECUTION3.1 INSTALLATION3.1.1 Trenching3.1.2 Piping System3.1.2.1 Clearances3.1.2.2 Minimum Pitch3.1.2.3 Thrust Blocks3.1.2.4 Minimum Backfill Cover3.1.2.5 Restoration3.1.2.6 Sterilization3.1.3 Piping Installation3.1.3.1 Polyvinyl Chloride (PVC) Pipe3.1.3.2 Soldered Copper Tubing3.1.3.3 Threade

14、d Brass or Galvanized Steel Pipe3.1.3.4 Polyethylene (PE) Pipe and Drip Tubing3.1.3.5 Dielectric Protection3.1.4 Irrigation Heads3.1.4.1 Fixed Riser Irrigation Heads3.1.4.2 Pop-Up Irrigation Head3.1.4.3 Drip Heads3.1.5 Valves3.1.5.1 Isolation Valves3.1.5.2 Control Valves3.1.5.3 Quick Coupling Valves

15、3.1.5.4 Hose Bibb3.1.5.5 Drain Valves3.1.6 Backflow Preventers3.1.6.1 Reduced Pressure Backflow Preventer3.1.6.2 Pressure Vacuum Breaker3.1.6.3 Atmospheric Vacuum Breaker3.1.7 Accessories3.1.7.1 Connection To Existing Water Supply Systems (Tapping Tee)3.1.7.2 Water Meter3.1.7.3 Valve Boxes and Lids3

16、.1.7.4 Backflow Preventer Enclosure3.1.7.5 Rain and Freeze Shut-Off Devices3.1.7.6 Soil Moisture Sensing Device3.1.7.7 Air/Vacuum Relief Valve3.1.8 Electrical Circuits3.1.8.1 Loops3.1.8.2 Expansion and ContractionSECTION 32 84 24 Page 3Provided by IHSNot for ResaleNo reproduction or networking permi

17、tted without license from IHS-,-,-3.1.8.3 Splices3.1.9 Automatic Controller3.1.10 Flushing3.1.11 Adjustment3.1.12 Sterilization3.2 FIELD QUALITY CONTROL3.2.1 Pressure Test3.2.1.1 Duration3.2.1.2 Leaks3.2.1.3 Retest3.2.2 Operation Test3.2.2.1 Accessories3.2.2.2 Acceptance3.2.3 Controller Charts- End

18、of Section Table of Contents -SECTION 32 84 24 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-32 84 24 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-32 84 24 (May 2010) UNIFIED FACILITIES GUIDE S

19、PECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 32 84 24IRRIGATION SPRINKLER SYSTEMS08/11*NOTE: This guide specification covers the requirements for irrigation sprinkler systems.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when edit

20、ing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements n

21、ot required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: Some paragraphs may need to be supplemented to meet project requirements.*PA

22、RT 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards C

23、heck Reference feature when you add a RID outside of the Sections Reference Article to automatically place the SECTION 32 84 24 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-reference in the Reference Article. Also use the Reference Wizards C

24、heck Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the e

25、xtent referenced. The publications are referred to within the text by the basic designation only.AMERICAN PETROLEUM INSTITUTE (API)API Std 598 (2009) Valve Inspecting and TestingAMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE)ASSE 1010 (2004) Performance Requirements for Water Hammer Arresters (ANSI

26、approved 2004)ASSE 1020 (2004; Errata 2004; Errata 2004) Performance Requirements for Pressure Vacuum Breaker Assembly (ANSI Approved 2004)ASSE Series 5000 (2009) Cross-Connection Control Professional Qualification StandardAMERICAN WATER WORKS ASSOCIATION (AWWA)AWWA C500 (2009) Metal-Seated Gate Val

27、ves for Water Supply ServiceAWWA C511 (2007) Standard for Reduced-Pressure Principle Backflow Prevention AssemblyAWWA C651 (2005; Errata 2005) Standard for Disinfecting Water MainsAWWA C901 (2008) Polyethylene (PE) Pressure Pipe and Tubing, 1/2 In. (13mm) Through 3 In. (76 mm), for Water ServiceAWWA

28、 M14 (2004; 3rd Ed) Manual: Recommended Practice for Backflow Prevention and Cross-Connection ControlASME INTERNATIONAL (ASME)ASME B1.2 (1983; Errata 1992; R 2007) Gages and Gaging for Unified Inch Screw ThreadsASME B16.15 (2006) Cast Bronze Alloy Threaded Fittings Classes 125 and 250ASME B16.18 (20

29、01; R 2005) Cast Copper Alloy Solder SECTION 32 84 24 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Joint Pressure FittingsASME B16.22 (2001; R 2010) Standard for Wrought Copper and Copper Alloy Solder Joint Pressure FittingsASME B16.3 (2010)

30、 Malleable Iron Threaded Fittings, Classes 150 and 300ASME B40.100 (2005) Pressure Gauges and Gauge AttachmentsASTM INTERNATIONAL (ASTM)ASTM A53/A53M (2010) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and SeamlessASTM B32 (2008) Standard Specification for Solder

31、 MetalASTM B43 (2009) Standard Specification for Seamless Red Brass Pipe, Standard SizesASTM B88 (2009) Standard Specification for Seamless Copper Water TubeASTM B88M (2005) Standard Specification for Seamless Copper Water Tube (Metric)ASTM D 1785 (2006) Standard Specification for Poly(Vinyl Chlorid

32、e) (PVC), Plastic Pipe, Schedules 40, 80, and 120ASTM D 2241 (2009) Standard Specification for Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series)ASTM D 2287 (1996; R 2010) Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion CompoundsASTM D 2464 (2006) Standard Specification

33、for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80ASTM D 2466 (2006) Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40ASTM D 2564 (2004; R 2009e1) Standard Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping S

34、ystemsASTM D 2774 (2008) Underground Installation of Thermoplastic Pressure PipingASTM D 2855 (1996; R 2010) Standard Practice for Making Solvent-Cemented Joints with SECTION 32 84 24 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Poly(Vinyl C

35、hloride) (PVC) Pipe and FittingsASTM D 3261 (2010a) Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and TubingASTM F 441/F 441M (2009) Standard Specification for Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 8

36、0FOUNDATION FOR CROSS-CONNECTION CONTROL AND HYDRAULIC RESEARCH (FCCCHR)FCCCHR List (continuously updated) List of Approved Backflow Prevention AssembliesMANUFACTURERS STANDARDIZATION SOCIETY OF THE VALVE AND FITTINGS INDUSTRY (MSS)MSS SP-80 (2008) Bronze Gate, Globe, Angle and Check ValvesMSS SP-85

37、 (2002) Gray Iron Globe R 2005; Errata 2008) Standard for Controllers, Contactors, and Overload Relays Rated 600 VNEMA ICS 6 (1993; R 2006) EnclosuresNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70 (2011; TIA 11-1; Errata 2011) National Electrical CodeNSF INTERNATIONAL (NSF)NSF/ANSI 14 (2011a) Pl

38、astics Piping System Components and Related MaterialsU.S. GENERAL SERVICES ADMINISTRATION (GSA)CID A-A-51145 (Rev D; Notice 1) Flux, Soldering, Non-Electronic, Paste and LiquidUNDERWRITERS LABORATORIES (UL)UL 651 (2005; Reprint Mar 2010) Standard for Schedule 40 and 80 Rigid PVC Conduit and Fittings

39、1.2 RELATED REQUIREMENTS*SECTION 32 84 24 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTE: Use only when using water pumps.*Section 23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS, and Section 26 00 00.00 20 BASIC ELECTRICAL MATERIAL

40、S AND METHODS, applies to this section, with additions and modifications specified herein.1.3 SYSTEM DESCRIPTIONThis system is designed with a water pressure minimum of _ kPa pounds per square inch (psi) maximum of _ kPa psi at connection to main meter building backflow prevention device and _ kPa p

41、si at the last head in each zone. Provide a system pressure calculations and irrigation requirements of the area. If pressure falls above or below indicated values, Contractor shall notify Contracting Officer. For Irrigation Sprinkler System, indicate the following:a. Head, piping, valve, controller

42、, sensor layout.b. Pipe, valve, backflow preventer, and controller.*NOTE: Use the following in freeze-thaw climates only.*c. Invert elevations. Indicate obstructions interfering with operation.*NOTE: At the text below, if source of water supply is from station water system through a service line and

43、 water meter, determine amount of water required for station irrigation system from static pressure at point of connection of station main. These factors are essential in designing for system pressure. In many cases, water supply is adequate for short durations only. Provide adequate valves for each

44、 zone to irrigate an area effectively.*d. Water source equipment, including existing mains, piping, valves and meters.*NOTE: At the text below, the system pressure and irrigation requirements of the area are determined from water supply, static pressure, soil, plants, freezing conditions, elevation changes, and wind direc