NEMA C136 25-2013 For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust Solid Objects and Moisture) for Luminaire Enclosures.pdf

上传人:ideacase155 文档编号:994002 上传时间:2019-03-16 格式:PDF 页数:15 大小:489.70KB
下载 相关 举报
NEMA C136 25-2013 For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust Solid Objects and Moisture) for Luminaire Enclosures.pdf_第1页
第1页 / 共15页
NEMA C136 25-2013 For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust Solid Objects and Moisture) for Luminaire Enclosures.pdf_第2页
第2页 / 共15页
NEMA C136 25-2013 For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust Solid Objects and Moisture) for Luminaire Enclosures.pdf_第3页
第3页 / 共15页
NEMA C136 25-2013 For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust Solid Objects and Moisture) for Luminaire Enclosures.pdf_第4页
第4页 / 共15页
NEMA C136 25-2013 For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust Solid Objects and Moisture) for Luminaire Enclosures.pdf_第5页
第5页 / 共15页
点击查看更多>>
资源描述

1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C136.25-2013American NationalStandard For Roadwayand Area LightingEquipmentIngressProtection (Resistance toDust, Solid Objects, andMoisture) for LuminaireEnclosuresANSI C136.25-2013 American National Standard For Roadway and

2、 Area Lighting Equipment Ingress Protection (Resistance to Dust, Solid Objects, and Moisture) for Luminaire Enclosures Secretariat: National Electrical Manufacturers Association Approved August 28, 2013 Published October 1, 2013 American National Standards Institute, Inc. ANSI C136.25-2013 Page ii C

3、opyright 2013 by National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily m

4、ean that there is unanimous agreement among every person participating in the development of this document. American National Standards Institute (ANSI) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards developm

5、ent process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and i

6、t does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether s

7、pecial, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, an

8、d disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and ma

9、king this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judg

10、ment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additio

11、nal views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other

12、 statement of compliance with any health or safetyrelated information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. ANSI C136.25-2013 Page iii Copyright 2013 by National Electrical Manufacturers Association AMERICAN NA

13、TIONAL STANDARD Approval of an American National Standard requires verification by ANSI. ANSI states that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standar

14、ds Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means significantly more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and a concerted effort be made toward

15、 their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether they have approved the standards or not, from: manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the s

16、tandards. The American National Standards Institute does not develop standards, and will under no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of t

17、he American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. Caution Notice: This American National Standard may be revised or withdrawn at any time. The procedures of the American Nati

18、onal Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electri

19、cal Manufacturers Association 1300 North 17th Street, Rosslyn, VA 22209 Copyright 2013 by National Electrical Manufacturers Association All rights reserved including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Litera

20、ry and Artistic Works, and the International and Pan American Copyright Conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherw ise, and w ithout the prior w ritten permission of the publisher. Printed in the United States of America. ANSI

21、C136.25-2013 Page iv Copyright 2013 by National Electrical Manufacturers Association ANSI C136.25-2013 Page v Copyright 2013 by National Electrical Manufacturers Association TABLE OF CONTENTS 1 SCOPE. 1 2 INFORMATIVE REFERENCES 1 3 DEFINITIONS 1 4 DESIGNATION OF PROTECTION 2 5 DEGREES OF PROTECTION

22、AGAINST ACCESS TO HAZARDOUS PARTS (FIRST NUMERAL) 2 6 DEGREES OF PROTECTION AGAINST FOREIGN OBJECTS, SUCH AS DUST 3 7 DEGREES OF PROTECTION AGAINST INGRESS OF MOISTURE (SECOND NUMERAL) . 4 8 MARKINGS . 5 9 GENERAL TEST REQUIREMENTS 6 10 SUGGESTED RATINGS . 6 Tables Table 1 DEGREES OF PROTECTION (OF

23、PERSONS) AGAINST ACCESS TO HAZARDOUS PARTS INDICATED BY THE FIRST CHARACTERISTIC NUMERAL*. 3 Table 2. 4 DEGREES OF PROTECTION AGAINST SOLID FOREIGN OBJECTS INDICATED BY THE FIRST CHARACTERISTIC NUMERAL* 4 Table 3. 5 DEGREES OF PROTECTION AGAINST WATER AS INDICATED BY THE SECOND CHARACTERISTIC NUMERA

24、L*. 5 Table 4. 7 SUGGESTED IP RATINGS FOR ANSI C136 EQUIPMENT 7 ANSI C136.25-2013 Page vi Copyright 2013 by National Electrical Manufacturers Association FOREWORD At the time this standard was approved the ANSI C136 committee was composed of the following members: Alabama Power Company American Elec

25、tric Lighting Caltrans Ceravision City of Kansas City, Missouri Duke Energy Duke Energy - Florida Eaton Cooper Lighting Edison Electric Institute EPRI EYE Lighting Florida Power and Light FRE Composites (2005) Inc. GE Lighting Solutions Georgia Power Company Gulf Power Company Hapco Holophane, An Ac

26、uity Brands Company Hubbell Lighting, Inc. Inovus Solar Kauffman Consulting, LLC LED Roadway Lighting Lites Los Angeles City Bureau of Street Lighting National Grid OSRAM Sylvania Philips Hadco Philips Lumec PNNL ROAM/DTL SELC Shakespeare Composite Structures South Carolina Electric and IEC 60598-1,

27、 Luminaires, general requirements, and tests, Section 9, “Resistance to dust, solid objects and moisture.” Tables 1, 2, and 3, in particular, are based on IEC 60529. The type of protection covered by this standard is as follows: a) Protection of persons against contact with, or approach to, energize

28、d electrical components inside the light fixture (luminaire) enclosure, and protection of the equipment against ingress of solid foreign bodies b) Protection of equipment inside an enclosure against harmful ingress of water, solid foreign objects or dust It should be noted that the IP rating of a lu

29、minaire has no bearing on its Dirt Depreciation characteristics. Testing is performed on new luminaires and is not an indicator of the life or reliability of the luminaire during its service life. Some components such as seals and gaskets deteriorate over time with exposure to heat and the environme

30、nt and should be evaluated separately. 2 INFORMATIVE REFERENCES This standard is intended to be used in conjunction with the following publications. The latest edition of the publication applies (including amendments). IEC 60529, Edition 2.1, Degrees of protection provided by enclosures (IP Code) IE

31、C 60598-1, Edition 7, Luminaires Part 1: general requirements, and tests, Section 9, “Resistance to dust, solid objects and moisture.” 3 DEFINITIONS Degrees of protection: The extent of protection provided by a lighting fixture (luminaire) enclosure against ingress of foreign objects or water, verif

32、ied by standardized test methods. Direct contact: Contact of persons with energized components. Enclosure: A part that provides protection of equipment against external effects and direct contact. Hazardous live part: A part that, when energized, presents a danger to human touch. Hazardous part: A p

33、art that presents a danger to human touch. IP code: A coding system to indicate the degree of protection afforded by a lighting fixture (luminaire) enclosure against ingress of foreign objects or water. ANSI C136.25-2013 Page 2 Copyright 2013 by National Electrical Manufacturers Association Opening:

34、 A gap or aperture in an enclosure that exists or may be formed by the introduction of a test probe. Probe, access: A test probe simulating a part of a person or tool to verify the possibility of ingress into an enclosure. Probe, object: A test probe simulating a foreign object to verify the possibi

35、lity of ingress into an enclosure. Protection provided by an enclosure against access to hazardous parts: The protection of persons against contact with hazardous parts or hazardous live parts. This protection may be provided by the enclosure itself or by means of barriers as part of the enclosure,

36、or distances inside the enclosure. 4 DESIGNATION OF PROTECTION The degree of protection provided by an enclosure is indicated in the IP code in the following manner: Code letters IP (Ingress Protection) First numeral 0 6 (dust or foreign objects) Second numeral 0 8 (moisture) The first numeral shall

37、 indicate the degree of protection provided by the enclosure against human contact or object held by a person that could contact a hazardous part, and simultaneously, the protection of the equipment against the ingress of foreign objects, including dust. An enclosure shall only be designated with a

38、stated degree of protection indicated by the first numeral if it complies with all lower degrees of protection. The second numeral shall indicate the degree of protection provided by the enclosure against the harmful effects of the ingress of moisture. Where a numeral is not required to be specified

39、, the letter X shall replace it. When an enclosure (luminaire) provides different degrees of protection for different mounting arrangements, the relevant information shall be indicated by the manufacturer in the instructions and/or label related to the respective mounting arrangements. 5 DEGREES OF

40、PROTECTION AGAINST ACCESS TO HAZARDOUS PARTS (FIRST NUMERAL) The first characteristic numeral of the IP Code number indicates compliance with the following tests for the degree of protection against access to hazardous parts. It also indicates compliance with tests shown in the next section for the

41、degree of protection against solid foreign objects. The protection against access to hazardous parts is satisfactory if adequate clearance is kept between the specified access probe and hazardous parts. Lighting equipment operates at voltages below 1,000 VAC. For voltages less than 1,000 VAC, the ac

42、cess probe must not touch the hazardous live parts. For luminaires operating at voltages exceeding 1,000 VAC, when the access probe is placed in the unfavorable position(s) (positions where the probe is closest to un-insulated current-carrying parts), the equipment shall be capable of withstanding t

43、he dielectric tests as specified in the relevant product standard applicable to the equipment. ANSI C136.25-2013 Page 3 Copyright 2013 by National Electrical Manufacturers Association The maximum voltage should be considered when the dielectric test voltage and adequate clearance are determined. Des

44、cription of the tests is shown in Table 1. Table 1 DEGREES OF PROTECTION (OF PERSONS) AGAINST ACCESS TO HAZARDOUS PARTS INDICATED BY THE FIRST CHARACTERISTIC NUMERAL* First characteristic numeral Degree of protection of persons against hazardous parts Test definition 0 Non-protected None 1 Protected

45、 against access to hazardous parts with the back of a hand 50 mm access probe sphere, shall have adequate clearance from hazardous parts 2 Protected against access to hazardous parts with a finger 12 mm , 80 mm length, jointed test finger, shall have adequate clearance from hazardous parts 3 Protect

46、ed against access to hazardous parts with a tool 2.5 mm access probe shall not penetrate 4* Protected against access to hazardous parts with a wire 1.0 mm access probe shall not penetrate 5* Protected against access to hazardous parts with a wire 1.0 mm access probe shall not penetrate 6* Protected

47、against access to hazardous parts with a wire 1.0 mm access probe shall not penetrate * This table is based on Table 1 in IEC 60529. * Although it appears the same, numbers 4, 5, and 6 are differentiated in Table 2. 6 DEGREES OF PROTECTION AGAINST FOREIGN OBJECTS, SUCH AS DUST The first characterist

48、ic numeral of the IP Code indicates compliance with tests for the degree of protection against access to hazardous parts as described in Section 5, and compliance with tests shown in Table 2 for the degree of protection against solid foreign objects and dust. The protection against ingress of solid

49、foreign objects/dust implies that the full diameter of the probe shall not pass through an opening in the enclosure. Object probes for numerals 3 and 4 shall not penetrate the enclosure at all. Dust protected enclosures to numeral 5 allow a limited quantity of dust to penetrate under certain conditions. Dust tight enclosures to numeral 6 do not allow any dust to penetrate. ANSI C136.25-2013 Page 4 Copyright 2013 by National Electrical Manufacturers Association Table 2 DEGREES OF PROTECTION AGAINST SOLID FOREIGN OBJECTS INDICATED BY THE FIRST CHARAC

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1