1、Lessons Learned Entry: 0434Lesson Info:a71 Lesson Number: 0434a71 Lesson Date: 1996-07-17a71 Submitting Organization: JPLa71 Submitted by: J.A. RobertsSubject: Rusty Integrated Circuits (1973) Abstract: During the Viking program, rust spots were observed on the gold-plated Kovar lids of a number of

2、flat pack ICs. The cause was suspected to be chlorine from the lead tinning operation, and various polymeric coatings failed to prevent further corrosion.Following the use of any chlorinated product, a thorough and complete cleaning to remove all residual chlorine contamination is a necessity. Descr

3、iption of Driving Event: (Relevant Historical Lesson(s) Learned)During the Viking program, rust spots were observed on the gold-plated Kovar lids of a number of flat pack Integrated Circuits (I.C.) used in electronic equipment. Although the source was not clearly identified, chlorine apparently init

4、iated the corrosion. The chlorine is presumed to have been within activated solder flux residues from the lead tinning operation. In some cases, the corrosion penetrated through the I.C. lid and was a potential cause of I.C. failure.Although various polymeric coatings were applied over the metallic

5、coatings to interrupt the corrosion cycle, they were all permeable enough to permit water through to the Kovar surface and the corrosion continued.Reference(s): PFR 32492Lesson(s) Learned: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Corrosion, on

6、ce started, is extremely difficult to stop.Recommendation(s): Following the use of any chlorinated product, a thorough and complete cleaning to remove all residual chlorine contamination is a necessity.Evidence of Recurrence Control Effectiveness: N/ADocuments Related to Lesson: N/AMission Directora

7、te(s): N/AAdditional Key Phrase(s): a71 Hardwarea71 Parts Materials & ProcessesAdditional Info: Approval Info: a71 Approval Date: 1996-04-04a71 Approval Name: Carol Dumaina71 Approval Organization: 125-204a71 Approval Phone Number: 818-354-8242Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DLA MS27222 REV M-2003 RELAYS ELECTROMAGNETIC 50 AMPERES 3 PST N O TYPE I HERMETICALLY SEALED《I型3 PST N O  50安培密封电磁继电器》.pdf DLA MS27222 REV M-2003 RELAYS ELECTROMAGNETIC 50 AMPERES 3 PST N O TYPE I HERMETICALLY SEALED《I型3 PST N O 50安培密封电磁继电器》.pdf
  • DLA MS27223 REV C VALID NOTICE 1-2013 Nipple Assembly 90 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines 1 4 Inch through 2 Inch Tube Sizes.pdf DLA MS27223 REV C VALID NOTICE 1-2013 Nipple Assembly 90 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines 1 4 Inch through 2 Inch Tube Sizes.pdf
  • DLA MS27223 REV C-2007 NIPPLE ASSEMBLY 90 ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES 1 4 INCH THROUGH 2 INCH TUBE SIZES《通过1 4英寸至2英寸的石油管道可重复使用的90度螺纹接口液压法兰软管组件适配器》.pdf DLA MS27223 REV C-2007 NIPPLE ASSEMBLY 90 ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES 1 4 INCH THROUGH 2 INCH TUBE SIZES《通过1 4英寸至2英寸的石油管道可重复使用的90度螺纹接口液压法兰软管组件适配器》.pdf
  • DLA MS27224 REV B VALID NOTICE 1-2013 Swivel Nut Assembly 90 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines 1 4 Inch Through 2 1 2 Inch Tube Sizes.pdf DLA MS27224 REV B VALID NOTICE 1-2013 Swivel Nut Assembly 90 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines 1 4 Inch Through 2 1 2 Inch Tube Sizes.pdf
  • DLA MS27224 REV B-2007 SWIVEL NUT ASSEMBLY 90 ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES 1 4 INCH THROUGH 2 1 2 INCH TUBE SIZES《通过1 4英寸至2 1 2英寸的石油管道可重复使用的90度旋转螺母法兰软.pdf DLA MS27224 REV B-2007 SWIVEL NUT ASSEMBLY 90 ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES 1 4 INCH THROUGH 2 1 2 INCH TUBE SIZES《通过1 4英寸至2 1 2英寸的石油管道可重复使用的90度旋转螺母法兰软.pdf
  • DLA MS27225 REV C VALID NOTICE 1-2013 Nipple Assembly 45 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines.pdf DLA MS27225 REV C VALID NOTICE 1-2013 Nipple Assembly 45 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines.pdf
  • DLA MS27225 REV C-2007 NIPPLE ASSEMBLY 45 DEG  ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES《可重复使用的45度螺纹接口软管组件适配器》.pdf DLA MS27225 REV C-2007 NIPPLE ASSEMBLY 45 DEG ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES《可重复使用的45度螺纹接口软管组件适配器》.pdf
  • DLA MS27226 REV B VALID NOTICE 1-2013 Swivel Nut Assembly 45 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines.pdf DLA MS27226 REV B VALID NOTICE 1-2013 Swivel Nut Assembly 45 Degrees Adapter Hose to Tube Reusable Hydraulic Fuel and Oil Lines.pdf
  • DLA MS27226 REV B-2007 SWIVEL NUT ASSEMBLY 45 DEGREE ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES《可重复使用的45度旋转螺母法兰软管组件适配器》.pdf DLA MS27226 REV B-2007 SWIVEL NUT ASSEMBLY 45 DEGREE ADAPTER HOSE TO TUBE REUSABLE HYDRAULIC FUEL AND OIL LINES《可重复使用的45度旋转螺母法兰软管组件适配器》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1