1、Best Practices Entry: Best Practice Info:a71 Committee Approval Date: 2000-04-24a71 Center Point of Contact: KSCa71 Submitted by: Wilson HarkinsSubject: Fiber Optic Systems Practice: During new design or upgrades to existing transmission systems, consider the use of fiber optic systems in place of m

2、etallic cable systems.Programs that Certify Usage: This practice has been used on the Kennedy Space Center Ground Support Systems (e.g., Launch Processing System, Ground Communications System).Center to Contact for Information: KSCImplementation Method: This Lesson Learned is based on Maintainabilit

3、y Technique number OPS-08 from NASA Technical Memorandum 4628, Recommended Techniques for Effective Maintainability.Properly designed fiber optic transmission systems will last for long periods of time without any preventive maintenance and can offer reduced maintenance downtime and repair costs. We

4、ll-built optical transmission lines and couplers are relatively immune to electromagnetic interference, adverse temperature, and moisture conditions and can be used for underwater cable. An optic fiber can be 20 times lighter and five times smaller than copper wire and still carry far more energy. U

5、sing fiber optic control circuits provides electrical isolation for safety in hazardous environments. Because optical cables carry no current they are safe to use in explosive environments and eliminate the hazards of short circuits in metal wires and cables.Provided by IHSNot for ResaleNo reproduct

6、ion or networking permitted without license from IHS-,-,-Components and OperationThe basic elements found in fiber optic systems are a transmitter, fiber optic cable, receiver, and connectors. Figure 1 illustrates the main parts of a fiber optic system. The following is a brief description of these

7、elements and their function:a71 The Transmitter converts an electrical signal to a light signal. The transmitter consists of a driver and a source. The input to the driver is the signal from the equipment being served. The driver circuit changes the input signal into a form required to operate the s

8、ource. The source, either a light-emitting diode (LED) or laser diode, does the actual conversion.a71 The Fiber Optic Cable is the medium for carrying the light signal. The main parts of a fiber cable are the optical fiber, cladding, buffer jacket, buffer, strength members, and jacket. Figure 2 illu

9、strates the main parts of a single fiber cable. The optical fiber contains two concentric layers called the core and the cladding. The inner core is the light-carrying part. The surrounding cladding provides the difference in refractive index that allows total internal reflection of light through th

10、e core. The buffer is the plastic coating applied to the cladding.refer to D descriptionD Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-refer to D descriptionD Cable buffers are one of two types, loose or tight. The loose buffer uses a hard plastic

11、 tube having an inside diameter several times that of the fiber. One or more fibers lie within the buffer tube. The tube isolates the fiber from the rest of the cable and the mechanical forces acting on it. The buffer becomes the load bearing member. As the cable expands and shrinks with changes in

12、temperature, it Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-does not affect the fiber as much. A fiber has a lower temperature coefficient than most cable elements, meaning that it expands and contracts less. The tight buffer has a plastic direct

13、ly applied over the fiber coating.This construction provides better crush and impact resistance; however, it does not protect the fiber as well from stresses of temperature variations. Because the plastic expands and contracts at a different rate than the fiber, contractions caused by variations in

14、temperature can result in loss-producing microbends. Tight buffers are more flexible and allow tighter turn radii. Therefore; tight tube buffers are useful for indoor applications where temperature variations are minimal and the capability to make tight turns inside walls is desired.Strength members

15、 add mechanical strength to the fiber cable. The most common strength members are Kevlar Aramid yarn, steel, and fiberglass epoxy rods. During and after installation, the strength members handle the tensile stresses applied to the cable so that the fiber is not damaged. Kevlar is most commonly used

16、when individual fibers are placed within their own jackets. Steel and fiberglass members find use in multi-fiber cables. Steel offers better strength than fiberglass, but may not be the best choice for maintaining an all dielectric cable. Steel also attracts lighting, whereas insulation provides pro

17、tection from the fiber does not. The jacket-like wire insulation provides protection from the effects of abrasion, oil, ozone, acids, alkali, solvents, etc. The choice of jacket material depends on the degree of resistance required for different influences and costs.a71 The Receiver accepts the ligh

18、t signal and converts it back to an electrical signal. The receiver contains a detector, amplifier, and an output section. The amplifier enhances the attenuated signal from the detector. The output section performs many functions such as: separation of the clock and data, pulse reshaping and timing,

19、 level shifting to ensure compatibility (TTL, ECL, etc.) and gain control.a71 Connectors and splices, which link the various components of a fiber optic system, are vital to system performance. A connector is defined as a disconnectable device used to connect a fiber to a source, detector, or anothe

20、r fiber. It is designed to be easily connected and disconnected many times. A splice is a device used to connect one fiber to another permanently. Connection by splices and connectors couples light from one component to another with as little loss of optical power as possible. The key to a fiber opt

21、ic connection is precise alignment of the mated fiber cores (or spots in single-mode fibers) so that nearly all the light is coupled from one fiber across the junction to the other fiber. Contact between the fibers is not required. However, the demands of precise alignment on small fibers create a c

22、hallenge to the designer of the connector or splice.Maintainability design features that should be addressed in the design for fiber optic systems should provide for fault localization and isolation, modular replacement, and built-in test and check-out capability.ImprovementsProvided by IHSNot for R

23、esaleNo reproduction or networking permitted without license from IHS-,-,-Fiber optics systems offer many benefits. In sensing systems, sensitive electronics can be isolated from shock, vibration, and harsh environments, resulting in more economical packaging. The number of repeaters required for lo

24、w attenuation cable is less than with conventional systems and for short hauls of less than 10 km, no repeaters are necessary. In the absence of electrical current, the life of a fiber optic systems components equals the useful life of the control system, the light source, and the electronics. Maint

25、enance and repair costs are reduced dramatically. Installation costs of fiber optic cables are lower than metal cables because the shipping and handling costs are about one-fourth and labor costs one-half that of current metal cables.Reference:1. RADC-TR-88-124, Impact of Fiber Optics on System Reli

26、ability and Maintainability, June 1988.2. RADC-TR-80-322, Failure Rates for Fiber Optic Assemblies, October 1980.3. AWP, Technicians Guide for Fiber Optics, 1987.Impact of Non-Practice: Fiber optics can enhance the transmission quality, capacity, and safety environment of the system. The system desi

27、gner should carefully weight the pros and cons of fiber optics vs. copper, microwave, or satellite for the transmission medium. Optical fiber, if cabled and installed properly, will last for years without any preventive maintenance. Reliability of optical cable is very good, and will enhance system

28、availability, minimize downtime for maintenance, and reduce repair costs.Related Practices: N/AAdditional Info: Approval Info: a71 Approval Date: 2000-04-24a71 Approval Name: Eric Raynora71 Approval Organization: QSa71 Approval Phone Number: 202-358-4738Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • KS C IEC 62005-1-2007 Reliability of fibre optic interconnecting devices and passive components-Part 1:Introductory guide and definitions《纤维光学互连器件和无源元件的可靠性第1部分 引导指南及定义》.pdf KS C IEC 62005-1-2007 Reliability of fibre optic interconnecting devices and passive components-Part 1:Introductory guide and definitions《纤维光学互连器件和无源元件的可靠性第1部分 引导指南及定义》.pdf
  • KS C IEC 62008-2013 Performance characteristics and calibration methods for digital data acquisition systems and relevant software《数字数据获得系统及管理软件设备的性能特性及校正方法》.pdf KS C IEC 62008-2013 Performance characteristics and calibration methods for digital data acquisition systems and relevant software《数字数据获得系统及管理软件设备的性能特性及校正方法》.pdf
  • KS C IEC 62018-2006 Power consumption of information technology equipment-Measurement methods《信息技术设备的功率消耗 测量方法》.pdf KS C IEC 62018-2006 Power consumption of information technology equipment-Measurement methods《信息技术设备的功率消耗 测量方法》.pdf
  • KS C IEC 62022-2012 Installed monitors for the control and detection of gamma radiations contained in recyclable or non-recyclable materials transported by vehicles《车辆运输的再生和非再生物质内包.pdf KS C IEC 62022-2012 Installed monitors for the control and detection of gamma radiations contained in recyclable or non-recyclable materials transported by vehicles《车辆运输的再生和非再生物质内包.pdf
  • KS C IEC 62026-1-2008 Low-voltage switchgear and controlgear-Controller-device interfaces(CDIs)-Part 1:General rules《低压开关装置和控制装置 控制器装置接口(CDIs) 第1部分 通用规则》.pdf KS C IEC 62026-1-2008 Low-voltage switchgear and controlgear-Controller-device interfaces(CDIs)-Part 1:General rules《低压开关装置和控制装置 控制器装置接口(CDIs) 第1部分 通用规则》.pdf
  • KS C IEC 62026-2-2006 Low-voltage switchgear and controlgear-Controller-device interfaces(CDIs)-Part 2:Actuator sensor interface(AS-i)《低压开关装置和控制装置 控制器装置接口(CDIs) 第2部分 操动件敏感元件接口(AS-i.pdf KS C IEC 62026-2-2006 Low-voltage switchgear and controlgear-Controller-device interfaces(CDIs)-Part 2:Actuator sensor interface(AS-i)《低压开关装置和控制装置 控制器装置接口(CDIs) 第2部分 操动件敏感元件接口(AS-i.pdf
  • KS C IEC 62026-3-2008 Low-voltage switchgear and controlgear-Controller-device interfaces(CDIs)-Part 3:DeviceNet《低压开关装置和控制装置 控制器装置接口(CDIs) 第3部分 器件网络(DeviceNet)》.pdf KS C IEC 62026-3-2008 Low-voltage switchgear and controlgear-Controller-device interfaces(CDIs)-Part 3:DeviceNet《低压开关装置和控制装置 控制器装置接口(CDIs) 第3部分 器件网络(DeviceNet)》.pdf
  • KS C IEC 62031-2011 LED modules for general lighting-Safety specifications《普通照明用发光二极管(LED)模块 安全规范》.pdf KS C IEC 62031-2011 LED modules for general lighting-Safety specifications《普通照明用发光二极管(LED)模块 安全规范》.pdf
  • KS C IEC 62035-2002 Discharge lamps(excluding fluorescent lamps)-Safety specifications《放电灯(不包括荧光灯) 安全规范》.pdf KS C IEC 62035-2002 Discharge lamps(excluding fluorescent lamps)-Safety specifications《放电灯(不包括荧光灯) 安全规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1