1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref

2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2015 SAE InternationalAll rights reserved. No part of this publi

3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out

4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visithttp:/www.sae.org/technical/standards/ARP1892BAEROSPACERECOMMENDED PRACTICEARP1892 REV. BIssued 1985-07Revised 1997-12Reaffirmed 20

5、15-10Superseding ARP1892AElectrical Connectors for Use in Battery Powered Ground Support EquipmentRATIONALEARP1892B has been reaffirmed to comply with the SAE five-year review policy.1. SCOPE:1.1 This SAE Aerospace Recommended Practice (ARP) describes a two-pole electric connector for use in battery

6、 powered ground support equipment, i.e., traction batteries. Alternatively, the connector can have two or more auxiliary contacts for auxiliary circuits. A handle may be added as an option to assist in connecting and disconnecting.2. REFERENCES:2.1 Applicable Documents:The following publications for

7、m a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herei

8、n, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.2.1.1 U.S. Government Publications: Available from DODSSP, Subscription Services Desk, Building 4D, 700 Robbins Avenue, Philadelp

9、hia, PA 19111-5094.MIL-C-79473. GENERAL DESCRIPTION:3.1 The connector shall have two power contacts.3.2 The amperage rating of the contacts shall be compatible with the size of the electrical conductors.The electrical conductors and contacts must provide sufficient cross-section of copper and carry

10、both the operating currents and charging currents of the electrical vehicle.3.3 The connector color shall designate the operating voltage and a key shall be provided to prevent mismatching connectors of different colors. The key must be an integral part of the connector housing and may not be remove

11、d.3.4 The connector shall be clearly marked for polarity (+ and -). It shall be designed such that the positive contact of one connector cannot be mated with the negative contact of the mating connector.Further, it shall not allow even momentary contact between the positive and negative, so as to dr

12、aw an arc.3.5 Live parts shall be recessed from the face of the connector to reduce the possibility of shorting.3.6 The removable portion of the connector pair shall be provided with means of being grasped during removal.3.7 The connector shall be a recognized component by U.L.* and C.S.A.* *Underwr

13、iters Laboratories, Inc.1285 Walt Whitman RoadMelville, Long Island, New York 11747*Canadian Standards Association178 Rexdale BoulevardToronto (Rexdale) OntarioCanada M9W IR34. PHYSICAL REQUIREMENTS:4.1 Housing:4.1.1 The housing shall be insulated to operate at 600 V. It shall be designed to pass a

14、dielectric strength test of 2200 V without leakage. The voltage should be applied for 60 s between each contact and between each contact and ground.4.1.2 The housing insulation material shall be impact resistant and shall withstand the impact of normal service conditions. The supplier shall supply i

15、mpact test data on request.SAE INTERNATIONAL ARP1892B 2 OF 44.1.3 The connector housing shall be color coded to designate voltage per the list below:a. Yellow - 12 Vb. Orange - 18 Vc. Red - 24 Vd. Gray - 36 Ve. Blue - 48 Vf. Green - 72 Vg. Black - 80 Vh. Brown - 96 Vi. Purple - 128 Vj. White - 144 V

16、In addition, the connector housing may be permanently marked to indicate voltage or an adhesive label may be attached to specify the designated voltage.4.1.4 The housing shall provide a means to secure mounting to the vehicle or battery.4.2 Contacts:4.2.1 All contacts shall be silverplated copper to

17、 provide minimum voltage drop and heating. The contact design shall be such that the contacts shall wipe when engaged and disengaged.4.2.2 The main contacts shall be marked or stamped to indicate the proper wire sizes.4.2.3 The connector shall be designed to plug and unplug 10,000 times minimum with

18、out electric load.These connectors are not load-breaking devices except in an emergency.5. PERFORMANCE:5.1 Temperature Rise:5.1.1 The resistance across mated pairs of connectors including the cable attachments shall be such that the temperature rise over ambient at rated amperage does not exceed 30

19、C (86 F) when wired with a cable of the proper rating.5.2 Cable Attachments:The cable shall be crimped or soldered or both to the main and auxiliary contacts. When the mechanical connection of the wire to the contact barrel is pulled to the minimum tensile strength listed below (per MIL-C-7947-lates

20、t revision), it shall not break or become distorted to the extent that it is unfit for further use.SAE INTERNATIONAL ARP1892B 3 OF 46. NOTES:6.1 The change bar ( l ) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have

21、 been made to the previous issue of this document. An (R) symbol to the left of the document title indicates a complete revision of the document.6.2 Table - wire to contact barrel, etc.For current capability, refer to the latest edition of The National Electric Code.PREPARED BY SAE SUBCOMMITTEE AGE-

22、2C, VEHICLE MAINTENANCEAND AIRCRAFT SERVICING OF COMMITTEE AGE-2, AIR CARGO ANDAIRCRAFT GROUND EQUIPMENT AND SYSTEMSTABLE 1 - Wire to Contact BarrelMinimum Tensile StrengthsConductor SizeAWGConductor Sizemm2Minimum Tensile StrengthlbMinimum Tensile Strength1Newtons12 3.3 110 4908 8.4 225 10004 21.2 400 17802 33.7 550 245035 565 251050 680 30300 53.5 700 311000 67.5 750 334070 810 360095 840 37400000 107.2 875 389011 lbf equals 4.45 N.SAE INTERNATIONAL ARP1892B 4 OF 4

展开阅读全文
相关资源
猜你喜欢
  • KS C IEC 60779-2012 Industrial electroheat equipment-Test methods for electroslag remelting furnaces《工业电热设备 电渣重熔炉的试验方法》.pdf KS C IEC 60779-2012 Industrial electroheat equipment-Test methods for electroslag remelting furnaces《工业电热设备 电渣重熔炉的试验方法》.pdf
  • KS C IEC 60780-2012 Nuclear power plants-Electrical equipment of the safety system-Qualification《核电厂 安全系统的电气设备 鉴定》.pdf KS C IEC 60780-2012 Nuclear power plants-Electrical equipment of the safety system-Qualification《核电厂 安全系统的电气设备 鉴定》.pdf
  • KS C IEC 60794-1-1-2007 Optical fibre cables-Part 1-1:Generic specification-General《光缆 第1-1部分 通用规范 总则》.pdf KS C IEC 60794-1-1-2007 Optical fibre cables-Part 1-1:Generic specification-General《光缆 第1-1部分 通用规范 总则》.pdf
  • KS C IEC 60794-2-10-2006 Optical fibre cables-Part 2-10:Indoor cables-Family specification for simplex and duplex cables《光缆 第2-10部分 室内单股和双股光缆系列规范》.pdf KS C IEC 60794-2-10-2006 Optical fibre cables-Part 2-10:Indoor cables-Family specification for simplex and duplex cables《光缆 第2-10部分 室内单股和双股光缆系列规范》.pdf
  • KS C IEC 60794-2-20-2006 Optical fibre cables-Part 2-20:Indoor cables-Family specification for multi-fibre optical distribution cables《光纤光缆 第2-20部分 室内光缆 多纤光学配电光缆的类规范》.pdf KS C IEC 60794-2-20-2006 Optical fibre cables-Part 2-20:Indoor cables-Family specification for multi-fibre optical distribution cables《光纤光缆 第2-20部分 室内光缆 多纤光学配电光缆的类规范》.pdf
  • KS C IEC 60794-2-2006 Optical fibre cables-Part 2:Indoor cables-Sectional specification《光缆 第2部分 室内电缆产品规范》.pdf KS C IEC 60794-2-2006 Optical fibre cables-Part 2:Indoor cables-Sectional specification《光缆 第2部分 室内电缆产品规范》.pdf
  • KS C IEC 60794-2-30-2006 Optical fibre cables-Part 2-30:Indoor cables-Family specification for optical fibre ribbon cables《光纤光缆 第2-30部分 室内光纤光缆 光纤带状光缆用系列规范》.pdf KS C IEC 60794-2-30-2006 Optical fibre cables-Part 2-30:Indoor cables-Family specification for optical fibre ribbon cables《光纤光缆 第2-30部分 室内光纤光缆 光纤带状光缆用系列规范》.pdf
  • KS C IEC 60794-2-40-2006 Optical fibre cables-Part 2-40:Indoor cables-Family specification for simplex and duplex cables with buffered A4 fibres《光缆 第2-40部分 室内光缆 A4光缆的系列规范》.pdf KS C IEC 60794-2-40-2006 Optical fibre cables-Part 2-40:Indoor cables-Family specification for simplex and duplex cables with buffered A4 fibres《光缆 第2-40部分 室内光缆 A4光缆的系列规范》.pdf
  • KS C IEC 60794-3-30-2006 Optical fibre cables-Part 3-30:Outdoor cables-Family specification for optical telecommunication cables for lake and river crossings《光缆 第3-30部分 室外光缆 湖、河流渡口.pdf KS C IEC 60794-3-30-2006 Optical fibre cables-Part 3-30:Outdoor cables-Family specification for optical telecommunication cables for lake and river crossings《光缆 第3-30部分 室外光缆 湖、河流渡口.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1