1、 AEROSPACE STANDARD FITTING, CONNECTOR, MULTIPLE FLUID PRESSURE LINE, 75 AS5163Copyright 2015 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recordin

2、g, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2000-07REAFFIRMED2015-04THIRD ANGLE PROJECTI

3、ON CUSTODIAN: G-3/G-3B FEDERAL SUPPLY CLASS 4730AS5163 SHEET 1 OF 3 PROCUREMENT SPECIFICATION: /4/ AS4875/1SAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate of technicalandengineering sciences. Theuse ofthisreportis entirelyvoluntary, andits applicab

4、ility and suitability forany particular use,including any patent infringement arising therefrom, is thesole responsibilityoftheuser.”SAE reviews eachtechnicalreport at least every five years at which time itmay berevised,reaffirmed, stabilized, orcancelled. SAE invites yourwrittencomments andsuggest

5、ions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS5163 RATIONALE AS5163 HAS BEEN REAFFIRMED TO COMPLY WITH THE SAE FIVE-YEAR REVIEW POLICY. FIGURE 1 - FITTING, CONNECTOR, 75AEROSPACE STANDARD AS5163 SHEET 2 OF 3 FITTING, CO

6、NNECTOR, MULTIPLE FLUID PRESSURE LINE, 75 NOTES:/1/ MATERIAL:a. DASH AS CODE LETTER - TYPE 4130 CARBON STEEL FORGING OR BAR PER AMS-S-6758 OR AMS 6370; OR TYPE 4140 PER AMS 6382. /2/b. CODE LETTER D - TYPE 2014-T6 ALUMINUM ALLOY FORGING PER AMS 4133; OR TYPE 2024-T6 ALUMINUM ALLOY BAR PER AMS-QQ-A-2

7、25/6 OR TYPE 2024-T851 ALUMINUM ALLOY BAR PER AMS-QQ-A-225/6 OR AMS 4339. /2/c. CODE LETTER J - TYPE 304 CORROSION RESISTANT STEEL FORGING OR BAR PER AMS-QQ-S-763 OR AMS 5639.d. CODE LETTER K - TYPE 316 CORROSION RESISTANT STEEL FORGING OR BAR PER AMS-QQ-S-763 OR AMS 5648.e. CODE LETTER R - TYPE 321

8、 CORROSION RESISTANT STEEL FORGING OR BAR PER AMS-QQ-S-763 OR AMS 5645.f. CODE LETTER T - TYPE 6AL-4V TITANIUM ALLOY FORGING OR BAR PER AMS 4928.g. CODE LETTER W - TYPE 7075-T73 ALUMINUM ALLOY FORGING PER AMS 4141; OR TYPE 7075-T73 ALUMINUM ALLOY BAR PER AMS-QQ-A-225/9; OR TYPE 7075-T7351 ALUMINUM A

9、LLOY BAR PER AMS 4124. /2/2/ HEAT TREATMENT:a. DASH AS CODE LETTER - SEE HARDNESS REQUIREMENT PER PROCUREMENT SPECIFICATION.b. CODE LETTERS D AND W - SEE ELECTRICAL CONDUCTIVITY AND HARDNESS REQUIREMENT PER PROCUREMENT SPECIFICATION.c. OTHER CODE LETTERS - NONE.TABLE 1A - DIMENSIONSBASIC NO.AS5163/1

10、3/SIZE CODE(NOMINALTUBESIZE)T THREADPERAS8879CLASS 3AA.023C.005D.005 EF.00104 .250 .4375-20 UNJF .836 .692 .474 .562 .43905 .312 .5000-20 UNJF .836 .755 .536 .625 .50106 .375 .5625-18 UNJF .898 .817 .599 .750 .56408 .500 .7500-16 UNJF 1.054 1.005 .786 .937 .75110 .625 .8750-14 UNJF 1.211 1.130 .911

11、1.125 .87612 .750 1.0625-12 UNJ 1.336 1.318 1.099 1.375 1.06316 1.000 1.3125-12 UNJ 1.523 1.568 1.349 1.687 1.313TABLE 1B - DIMENSIONS AND WEIGHTSBASIC NO.AS5163/13/SIZE CODE GH.010 K VLB/EAAPPROX.REFALLB/EAAPPROX.REFSTEELLB/EAAPPROX.REFTI04 .437 .750 .375 .797- .815 .0244 .0700 .038605 .437 .750 .5

12、00 .797- .815 .0192 .0550 .030306 .500 .875 .500 .985-1.003 .0354 .102 .056008 .500 1.125 .750 1.173-1.191 .0536 .154 .084910 .625 1.375 .812 1.355-1.380 .0871 .250 .13812 .625 1.625 1.000 1.668-1.693 .145 .415 .22916 .812 2.125 1.500 2.042-2.072 .242 .695 .383AEROSPACE STANDARD AS5163 SHEET 3 OF 3

13、FITTING, CONNECTOR, MULTIPLE FLUID PRESSURE LINE, 75 3. FINISH:a. DASH AS CODE LETTER - CADMIUM PLATE PER QQ-P-416, TYPE II, CLASS 2, DYE BLACK AND COAT WITH A LIGHT FILM OF OIL PER PROCUREMENT SPECIFICATION.b. CODE LETTER D - ANODIZE PER AMS 2472 OR MIL-A-8625, TYPE II, CLASS 2, DYE BLUE, DUPLEX SE

14、AL PER PROCUREMENT SPECIFICATION.c. CODE LETTERS J, K, AND R - PASSIVATE PER AMS-QQ-P-35, TYPE VI OR VII.d. CODE LETTER T - ANODIZE PER AMS 2488 OR FLUORIDE PHOSPHATE CONVERSION COAT PER AMS 2486 WITH COLOR PER PROCUREMENT SPECIFICATION.e. CODE LETTER W - ANODIZE PER MIL-A-8625, TYPE II, CLASS 2, DY

15、E BROWN, DUPLEX SEAL PER PROCUREMENT SPECIFICATION./4/ PROCUREMENT SPECIFICATION: AS4875/1 EXCEPT AS SPECIFIED ON THIS STANDARD. THIS PART SHALL BE QUALIFIED TO THE PROCUREMENT SPECIFICATION IN A COMPLETE ASSEMBLY AS APPLICABLE. USERS OF THIS STANDARD ARE ADVISED TO CONTROL SOURCE APPROVAL(S) BY STA

16、NDARD PAGE SUPPLEMENT SHEET OR SIMILAR MEANS./5/ IDENTIFICATION AT LOCATION SHOWN: MARK PER AS478 CLASS C OR D OR METHOD 7A3, 15A3, OR 15B.a. FOR SIZE 06 AND SMALLER: MANUFACTURERS NAME, CAGE CODE OR TRADEMARK, LETTERS “AS” AND MATERIAL CODE LETTER.b. FOR SIZE 08 AND LARGER: MANUFACTURERS NAME, CAGE

17、 CODE OR TRADEMARK, BASIC PART NUMBER AND MATERIAL CODE LETTER.6. INTENDED USE: THIS PART IS DESIGNED FOR USE IN SYSTEMS WITH MAXIMUM OPERATING PRESSURES AS FOLLOWS:a. SIZES 04 THROUGH 12 IN ALUMINUM ALLOY AND SIZES 04 THROUGH 16 IN CORROSION RESISTANT STEEL AND TITANIUM ALLOY AT 3000 psi.b. SIZE 16

18、 IN ALUMINUM ALLOY AT 1500 psi.THIS STANDARD IS THE FUNCTIONAL EQUIVALENT OF AN777 AND IS INTENDED TO BE SUITABLE AS A REPLACEMENT STANDARD.7. WHEN MACHINED FROM BAR OR OVERSIZED FORGINGS, THE CENTER BODY SECTION SHALL CONFORM TO AS1376, TABLE 8.8. INTERPRETATION OF DRAWING PER ARP4296.9. SURFACE TE

19、XTURE: SYMBOLS PER ASME Y14.36M; REQUIREMENTS PER ASME B46.1. UNLESS OTHERWISE SPECIFIED, MACHINED SURFACES TO BE 125 in Ra. FORGED SURFACES MAY BE 250 in Ra.10. BREAK EDGES .003 TO .015 UNLESS OTHERWISE SPECIFIED.11. DIMENSIONING AND TOLERANCING: ASME Y14.5M-1994.12. DIMENSIONS IN INCHES. UNLESS OTHERWISE SPECIFIED, TOLERANCES: LINEAR DIMENSIONS .016, ANGULAR DIMENSIONS 030./13/ EXAMPLE OF PART NUMBER:

展开阅读全文
相关资源
猜你喜欢
  • DL T 329-2010 Communications interfaces based on DL T 860 for low-voltage power supply equipment used in substation 《基于DL T 860的变电站低压电源设备通信接口》.pdf DL T 329-2010 Communications interfaces based on DL T 860 for low-voltage power supply equipment used in substation 《基于DL T 860的变电站低压电源设备通信接口》.pdf
  • DL T 330-2010 Ultrasonic time of flight diffraction technique in welded joints of hydroelectric or hydraulic engineering steel structure and equipment 《水电水利工程金属结构及设备焊接接头衍射时差法超声检测》.pdf DL T 330-2010 Ultrasonic time of flight diffraction technique in welded joints of hydroelectric or hydraulic engineering steel structure and equipment 《水电水利工程金属结构及设备焊接接头衍射时差法超声检测》.pdf
  • DL T 331-2010 Guide of the key parameter coordination for planning and design of generator and power network 《发电机与电网规划设计关键参数配合导则》.pdf DL T 331-2010 Guide of the key parameter coordination for planning and design of generator and power network 《发电机与电网规划设计关键参数配合导则》.pdf
  • DL T 332 1-2010 Guide for operation of tower type boiler supercritical units Part 1 Guide for operation of boiler 《塔式炉超临界机组运行导则 第1部分:锅炉运行导则》.pdf DL T 332 1-2010 Guide for operation of tower type boiler supercritical units Part 1 Guide for operation of boiler 《塔式炉超临界机组运行导则 第1部分:锅炉运行导则》.pdf
  • DL T 332 2-2010 Guide for operation of tower type boiler supercritical units Part 2 Guide for operation of steam turbine《塔式炉超临界机组运行导则 第2部分:汽轮机运行导则》.pdf DL T 332 2-2010 Guide for operation of tower type boiler supercritical units Part 2 Guide for operation of steam turbine《塔式炉超临界机组运行导则 第2部分:汽轮机运行导则》.pdf
  • DL T 332 3-2010 Guide for operation of tower type boiler supercritical units Part 3 Guide for operation of chemical《塔式炉超临界机组运行导则 第3部分:化学运行导则》.pdf DL T 332 3-2010 Guide for operation of tower type boiler supercritical units Part 3 Guide for operation of chemical《塔式炉超临界机组运行导则 第3部分:化学运行导则》.pdf
  • DL T 333 1-2010 Technique requirements of condensate polishing in thermal power plant Part1 Water-cooled unit 《火电厂凝结水精处理系统技术要求 第1部分:湿冷机组》.pdf DL T 333 1-2010 Technique requirements of condensate polishing in thermal power plant Part1 Water-cooled unit 《火电厂凝结水精处理系统技术要求 第1部分:湿冷机组》.pdf
  • DL T 333 2-2013 Technique requirements of condensate polishing in thermal power plants Part 2 Air-cooled units《火电厂凝结水精处理系统技术要求第2部分 空冷机组》.pdf DL T 333 2-2013 Technique requirements of condensate polishing in thermal power plants Part 2 Air-cooled units《火电厂凝结水精处理系统技术要求第2部分 空冷机组》.pdf
  • DL T 334-2010 Technical specification for measurement of electromagnetic environment of transmission and transformation projects 《输变电工程电磁环境监测技术规范》.pdf DL T 334-2010 Technical specification for measurement of electromagnetic environment of transmission and transformation projects 《输变电工程电磁环境监测技术规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1