1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2010 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside US
4、A) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J928_201011SURFACEVEHICLESTANDARDJ928 NOV2010 Issued 1965-07Reaffirmed 2010-11 Superseding J928
5、 JUN2006 Electrical TerminalsPin and Receptacle Type RATIONALEJ928 has been reaffirmed to comply with the SAE 5-Year Review policy. 1. SCOPE This SAE Standard covers general requirements and terminal interface dimensions of various sizes of pin and receptacle type terminals. 1.1 General Requirements
6、 The pin and receptacle type terminals listed in this SAE Standard may be used for terminating wire ends, or for terminating circuits on devices other than wire. Performance requirements for low tension wire terminals are specified in SAE J163. Terminals shall be free from burrs, corrosion, or any f
7、oreign matter, and shall be of a temper that will permit attachment to wires or circuits on devices without fracturing or cracking. Terminals may be applied to wire by crimping, welding, swaging, soldering, or any combination thereof at the conductor grip. Insulation grips shall be used on all termi
8、nals assembled to 2 mm2(14 ga) and smaller insulated wire except where usage provides other means of relieving strain. The type, thickness and finish of the metal used in fabricating these terminals may vary according to the end product use. The dimensions shown in Tables 1 and 2/Figures 1 and 2 are
9、 included to assure proper fits between manufacturing sources. Terminal sizes other than those listed are permissible, providing they meet the general requirements of this standard and the performance requirements of SAE J163. Pin terminals fabricated from rod or bar stock must provide suitable step
10、ped internal diameters to fit the wire conductors and insulation consistent with the method by which they are attached. Insertion and removal forces are also variables that can be adjusted to fit the end use. It is recommended, however, that single connections with indentures should not exceed 67 N
11、(15 lb) and multiple connections without indentures should not exceed 31 N (7 lb) per connection. SAE J928 Reaffirmed NOV2010 Page 2 of 4FIGURE 1TYPE I PIN TERMINALS FIGURE 2TYPE II PIN TERMINALSTABLE 1 - TYPE I PIN TERMINALS Nominal Dia mm Nominal Dia in SAE Wire Size Range A Min(1)mm A Min(1)in B
12、Min(1)mm B Min(1)in C mm C in D Nominalmm D Nominal in E Nominalmm E Nominalin F Nominalmm F Nominalin G Nominalmm G Nominalin Hmm H in 3.96 0.156 0.353.0 mm2(2212) 8.7 0.34 8.7 0.34 4.043.94 0.1590.155 3.81 0.150 3.73 0.147 4.60 0.181 0.86 0.034 5.560.219 4.57 0.180 0.355.0 mm2(2210) 10.2 0.40 10.2
13、 0.40 4.624.52 0.1820.178 4.42 0.174 4.830.190 1. Minimum insertion length. NOTE: Detent Female - When a female detent is required, the detentof the receptacle must match the H dimension of the pin. TABLE 2 - TYPE II PIN TERMINALS Nominal dia mm Nominal Dia in SAE Wire Size Range A Min(1)mm A Min(1)
14、in B Min(1)mm B Min(1)in C mm C in D Nominalmm D Nominalin E Nominalmm E Nominalin F Nominalmm F Nominalin G Nominalmm G Nominalin 2.18 0.086 0.352.0 mm2(2214) 4.4 0.17 4.4 0.17 2.182.11 0.0860.0832.03 0.080 2.36 0.093 0.352.0 mm2(2214) 5.4 0.21 5.4 0.21 2.362.31 0.0930.0912.18 0.086 2.18 0.086 3.40
15、 0.134 0.56 0.022 3.96 0.156 0.353.0 mm2(2212) 5.1 0.20 5.1 0.20 4.043.91 0.1590.1543.86 0.152 1. Minimum insertion length. SAE J928 Reaffirmed NOV2010 Page 3 of 4 SAE J928 Reaffirmed NOV2010 Page 4 of 42. REFERENCES 2.1 Applicable Publication The following publication forms a part of the specificat
16、ion to the extent specified herein. Unless otherwise indicated, the latest revision of SAE publications shall apply. 2.1.1 SAE Publication Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.SAE J
17、163 Low Tension Wiring and Cable Terminals and Splice Clips 3. NOTES 3.1 Marginal Indicia The change bar (l) located in the left margin is for the convenience of the user in locating areas where technical revisions have been made to the previous issue of the report. An (R) symbol to the left of the document title indicates a complete revision of the report. PREPARED BY THE SAE ELECTRICAL DISTRIBUTION SYSTEMS STANDARDS COMMITTEE REAFFIRMED BY THE SAE CONNECTOR SYSTEMS STANDARDS COMMITTEE