SANS 1423-5-2008 Performance requirements for textile fabrics of low flammability Part 5 Fabrics for use in movable office partitions《对低易燃性织物的性能要求 第5部分 活动办公室隔墙用织物》.pdf

上传人:explodesoak291 文档编号:1029324 上传时间:2019-03-24 格式:PDF 页数:14 大小:218.32KB
下载 相关 举报
SANS 1423-5-2008 Performance requirements for textile fabrics of low flammability Part 5 Fabrics for use in movable office partitions《对低易燃性织物的性能要求 第5部分 活动办公室隔墙用织物》.pdf_第1页
第1页 / 共14页
SANS 1423-5-2008 Performance requirements for textile fabrics of low flammability Part 5 Fabrics for use in movable office partitions《对低易燃性织物的性能要求 第5部分 活动办公室隔墙用织物》.pdf_第2页
第2页 / 共14页
SANS 1423-5-2008 Performance requirements for textile fabrics of low flammability Part 5 Fabrics for use in movable office partitions《对低易燃性织物的性能要求 第5部分 活动办公室隔墙用织物》.pdf_第3页
第3页 / 共14页
SANS 1423-5-2008 Performance requirements for textile fabrics of low flammability Part 5 Fabrics for use in movable office partitions《对低易燃性织物的性能要求 第5部分 活动办公室隔墙用织物》.pdf_第4页
第4页 / 共14页
SANS 1423-5-2008 Performance requirements for textile fabrics of low flammability Part 5 Fabrics for use in movable office partitions《对低易燃性织物的性能要求 第5部分 活动办公室隔墙用织物》.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA

2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any

3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-21246-9 SANS 1423-5:2008Edition 1.1Any reference to SABS 1423-5 is deemed to be a reference to this standard(Government Notice No. 1373 of

4、 8 November 2002)SOUTH AFRICAN NATIONAL STANDARD Performance requirements for textile fabrics of low flammability Part 5: Fabrics for use in movable office partitions Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 i

5、nternational code + 27 12 www.stansa.co.za Standards South Africa SANS 1423-5:2008 Edition 1.1 Table of changes Change No. Date Scope Amdt 1 2008 Amended to change the designation of SABS standards to SANS standards, and to update referenced standards. Foreword This South African standard was approv

6、ed by National Committee StanSA SC 5110.01J, Textiles Low flammable textile products, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This document was published in May 2008.This document supersedes SABS 1423-5:1994 (edition 1). A vertica

7、l line in the margin shows where the text has been technically modified by amendment No. 1. SANS 1423 consists of the following parts, under the general title Performance requirements for textile fabrics of low flammability: Part 1: Apparel fabrics. Part 2: Curtain and drape fabrics. Part 3: Upholst

8、ery fabrics. Part 4: Bedding fabrics, bedcovers and pillows. Part 5: Fabrics for use in movable office partitions. Annex A forms an integral part of this document. Annexes B, C, D and E are for information only. SANS 1423-5:2008 Edition 1.1 1 Contents Page Foreword 1 Scope . 3 2 Normative references

9、 3 3 Definitions 3 4 Requirements . 4 5 Labelling and marking 5 6 Methods of test . 5 6.1 Conditioning 5 6.2 Wet treatment 5 6.3 Preparation of composite test specimens (simulated partitions) . 5 6.4 Sequence of testing . 7 6.5 Surface flash . 7 6.6 Afterflame, afterglow and separation of flaming de

10、bris . 8 Annex A (normative) Notes to purchasers. 9 Annex B (informative) Quality verification of fabrics of low flammability for use in movable office partitions 9 Annex C (informative) Guidance for manufacturers 9 Annex D (informative) Test and evaluation flow chart. 10 Annex E (informative) Bibli

11、ography. 11 SANS 1423-5:2008 Edition 1.1 2 This page is intentionally left blank SANS 1423-5:2008 Edition 1.1 3 Performance requirements for textile fabrics of low flammability Part 5: Fabrics for use in movable office partitions 1 Scope This part of SANS 1423 specifies the flammability performance

12、requirements for two categories of fabrics for use in the make-up of movable office partitions. NOTE For the purpose of determining whether a fabric for use in movable office partitions is able to provide protection against ignition, the fabric is tested in conjunction with a substrate of known flam

13、mability. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this part of SANS 1423. All standards are subject to revision and, since any reference to a standard is deemed to be a reference to the latest edition of that s

14、tandard, parties to agreements based on this part of SANS 1423 are encouraged to take steps to ensure the use of the most recent editions of the standards indicated below. Information on currently valid national and international standards can be obtained from Standards South Africa. EN 312, Particl

15、eboards Specifications. Amdt 1 ISO 6941, Textile fabrics Burning behaviour Measurement of flame spread properties of vertically oriented specimens. SABS 1301, Particle board: interior type. Amdt 1 SANS 70, Conditioning of textiles, and standard temperate atmosphere for determining their physical and

16、 mechanical properties. SANS 1097, Dimensional changes in textile fabrics caused by immersion in cold water. SANS 6105, Surface burning properties of textile fabric with a raised fibre surface. 3 Definitions For the purposes of this part of SANS 1423, the following definitions apply: 3.1 afterflame

17、persistence of flaming of a material, under specified test conditions, after the ignition source has been removed SANS 1423-5:2008 Edition 1.1 4 3.2 afterglow persistence of glowing of a material after cessation of flaming or, if no flaming occurs, after the ignition source has been removed 3.3 flam

18、e-retardant foam, wadding or interliner a foam, wadding or interliner that has been suitably treated or manufactured to render it flame retardant. Flame-retardant foam, wadding or interliner does not ignite within a flame application time of 20 s and the afterflame time does not exceed 5 s NOTE In t

19、erms of ISO 6940, ignition is deemed to have occurred if the material or product ignites within 5 s after removal of the ignition source. 3.4 flaming debris material that separates from a specimen under specified test conditions and that continues to flame as it falls 3.5 flammability the ability, u

20、nder specified test conditions, of a material or product to burn with a flame 3.6 non-flame-retardant foam or wadding foam or wadding that is readily flammable, i.e. foam or wadding that ignites within a flame application time of 20 s 3.7 surface flash rapid spread of flame over the surface of a mat

21、erial, without ignition of the basic structure of the material. 4 Requirements The fabric shall be of one of the flammability performance categories given in 4.1 and 4.2, as required. 4.1 Category 1 When tested in conjunction with a non-flame-retardant foam or wadding (see 6.3), both before and afte

22、r wet treatment (see 6.2), a category 1 fabric shall comply with the requirements given in table 1. 4.2 Category 2 When tested in conjunction with a flame-retardant foam or wadding or in conjunction with a flame-retardant interliner and a non-flame-retardant foam or wadding (see 6.3), both before an

23、d after wet treatment (see 6.2), a category 2 fabric shall comply with the requirements given in table 1. SANS 1423-5:2008 Edition 1.1 5 Table 1 Flammability performance requirements 1 2 3 Property Requirement Test method subclause Surface flash1). No surface flash shall occur 6.5 Separation of flam

24、ing debris . No flaming debris 6.6 Mean afterflame time, s, max. 1 6.6 Mean afterglow time, s, max. 1 6.6 1) Applicable only in the case of raised or pile fabrics. 5 Labelling and marking The flammability performance category shall appear in legible and indelible marking on a label securely attached

25、 to the fabric. 6 Methods of test 6.1 Conditioning Condition the test samples in accordance with SANS 70 before cutting from each test sample the test specimens required for the tests given in 6.5 and 6.6. 6.2 Wet treatment When relevant, wet and dry the specimens in accordance with the procedure gi

26、ven in SANS 1097. NOTE Only the fabric is subjected to a wet treatment. 6.3 Preparation of composite test specimens (simulated partitions) 6.3.1 Materials and dimensions 6.3.1.1 Test frame, as shown in figure 1. SANS 1423-5:2008 Edition 1.1 6 Figure 1 Test frame 6.3.1.2 Foam, wadding or interliner,

27、either non-flame-retardant foam wadding (to be used when category 1 fabrics are being tested) or flame-retardant foam, wadding or interliner (to be used when category 2 fabrics are being tested) of dimensions 120 mm 600 mm and, in the case of foam or wadding, of thickness approximately 6 mm. 6.3.1.3

28、 Fabric under test, of dimensions 120 mm 600 mm. 6.3.2 Make-up of composite specimens In the case of category 1 fabrics, place the non-flame-retardant foam or wadding over the test frame and place the fabric under test over the foam or wadding. In the case of category 2 fabrics, either place the fla

29、me-retardant foam or wadding over the test frame and place the fabric under test over the foam or wadding, or place the non-flame-retardant foam or wadding over the test frame, place the flame-SANS 1423-5:2008 Edition 1.1 7 retardant interliner over the foam or wadding and then place the fabric unde

30、r test over this combination. In all cases, so staple the specimens along the edges that the fabric and foam/wadding/interliner are secure. If the dimensions of the fabric to be tested are insufficient to provide the required size of specimen, staple together shorter pieces of the fabric (without ov

31、erlapping), using not more than four equally spaced metal staples over the full width of the test specimen. In the case of a fabric that is intended to be bonded to a foam or a wadding, the supplier shall provide sufficient samples of the unbonded fabric for testing purposes. 6.4 Sequence of testing

32、 Note 1 A flow chart that illustrates the sequence of testing and the requirements is given in annex D. Note 2 Except for the surface flash test, testing is conducted on composite specimens only. To economize on the quantity of fabric required and on the time and costs involved in testing, perform t

33、he tests in the sequence given in 6.4.1 to 6.4.3. 6.4.1 Stage 1 In the case of a raised or a pile fabric, determine whether surface flash occurs (see 6.5) on test specimens of the fabric only, before the wet treatment (see 6.2). If surface flash does not occur, repeat the test on specimens that have

34、 been subjected to the wet treatment. If surface flash still does not occur, proceed to stage 2. If surface flash occurs on specimens either before or after the wet treatment, no further tests are required. 6.4.2 Stage 2 Test a composite specimen in conjunction with non-flame-retardant foam or waddi

35、ng in accordance with 6.6, before the wet treatment. If the mean afterflame time or the mean afterglow time exceeds 1 s or if there is flaming debris, proceed to stage 3. If the mean afterflame time or the mean afterglow time does not exceed 1 s and there is no flaming debris, retest the fabric afte

36、r the wet treatment. If the mean afterflame time or the mean afterglow time exceeds 1 s or if there is flaming debris, proceed to stage 3. If the mean afterflame time or the mean afterglow time does not exceed 1 s and there is no flaming debris, the fabric complies with the requirements for a catego

37、ry 1 fabric and no further tests are required. 6.4.3 Stage 3 Test a composite specimen in conjunction with either a flame-retardant foam or wadding, or a non-flame-retardant foam or wadding and a flame-retardant interliner, in accordance with 6.6, before the wet treatment. If the mean afterflame tim

38、e or the mean afterglow time exceeds 1 s or if there is flaming debris, then no further tests are required and the fabric fails to comply with the requirements of this part of SANS 1423. If the mean afterflame time or the mean afterglow time does not exceed 1 s and there is no flaming debris, retest

39、 the fabric after the wet treatment. If the mean afterflame time or the mean afterglow time exceeds 1 s or if there is flaming debris, the fabric fails to comply with the requirements of this part of SANS 1423. If the mean afterflame time or the mean afterglow time does not exceed 1 s and there is n

40、o flaming debris, then the fabric complies with the requirements for a category 2 fabric. 6.5 Surface flash Use SANS 6105. SANS 1423-5:2008 Edition 1.1 8 6.6 Afterflame, afterglow and separation of flaming debris Use the method given in ISO 6941, using a flame application time of 20 s, and measure t

41、he mean afterflame time and the mean afterglow time and check for the presence of flaming debris. SANS 1423-5:2008 Edition 1.1 9 Annex A (normative) Notes to purchasers The following requirement shall be specified in tender invitations and in each order or contract: The flammability performance cate

42、gory (see 4.1). Annex B (informative) Quality verification of fabrics of low flammability for use in movable office partitions When a purchaser requires ongoing verification of the quality of fabrics of low flammability for use in movable office partitions, it is suggested that, instead of concentra

43、ting solely on evaluation of the final product, he also direct his attention to the manufacturers quality system. In this connection it should be noted that SANS 9001 covers the provision of an integrated quality system. Amdt 1 Annex C (informative) Guidance for manufacturers Category 2 fabric of lo

44、w flammability used in the manufacture of movable office partitions should be used in conjunction with a flame-retardant foam or wadding, or with a non-flame-retardant foam or wadding and a flame-retardant interliner. SANS 1423-5:2008 Edition 1.1 10 Annex D (informative) Test and evaluation flow cha

45、rt The following flow chart illustrates the sequence in which tests are performed on specimens, both before and after a wet treatment, and the evaluations necessary to determine whether a fabric complies with the requirements of this part of SANS 1423. SANS 1423-5:2008 Edition 1.1 11 Annex E (informative) Bibliography ISO 6940, Textile fabrics Burning behaviour Determination of ease of ignition of vertically oriented specimens. SANS 9001/ISO 9001, Quality management systems Requirements. Amdt 1 Standards South Africa

展开阅读全文
相关资源
猜你喜欢
  • ASTM C1849 C1849M-2017 Standard Test Method for Density and Air Content (Pressure Method) of Freshly Mixed Roller-Compacted Concrete《新拌碾压混凝土密度和含气量的标准试验方法(加压法)》.pdf ASTM C1849 C1849M-2017 Standard Test Method for Density and Air Content (Pressure Method) of Freshly Mixed Roller-Compacted Concrete《新拌碾压混凝土密度和含气量的标准试验方法(加压法)》.pdf
  • ASTM C185-2002 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥用灰浆的空气含量的标准试验方法》.pdf ASTM C185-2002 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥用灰浆的空气含量的标准试验方法》.pdf
  • ASTM C185-2008 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥用灰浆的空气含量的试验方法》.pdf ASTM C185-2008 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥用灰浆的空气含量的试验方法》.pdf
  • ASTM C185-2015 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥灰浆空气含量的标准试验方法》.pdf ASTM C185-2015 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥灰浆空气含量的标准试验方法》.pdf
  • ASTM C185-2015a Standard Test Method for Air Content of Hydraulic Cement Mortar《液压水泥砂浆空气含量的标准试验方法》.pdf ASTM C185-2015a Standard Test Method for Air Content of Hydraulic Cement Mortar《液压水泥砂浆空气含量的标准试验方法》.pdf
  • ASTM C1850-2017 Standard Guide for Improved Laboratory Accelerated Tests to Predict the Weathering and for Use in Developing Protocols to Predict the Design Life of Building Sealan.pdf ASTM C1850-2017 Standard Guide for Improved Laboratory Accelerated Tests to Predict the Weathering and for Use in Developing Protocols to Predict the Design Life of Building Sealan.pdf
  • ASTM C1851-2018 Standard Practice for Determining the Extent of Cracking in a Sealant using the Difference between the Compressive and Tensile Modulus《用压缩模量和拉伸模量之差测定密封剂开裂程度的标准实施规程》.pdf ASTM C1851-2018 Standard Practice for Determining the Extent of Cracking in a Sealant using the Difference between the Compressive and Tensile Modulus《用压缩模量和拉伸模量之差测定密封剂开裂程度的标准实施规程》.pdf
  • ASTM C1852-2017 Standard Guide for Product Selection Delivery Systems for Aerosol Foam Sealants and Adhesives《气溶胶泡沫密封剂和粘合剂的产品选择 输送系统标准指南》.pdf ASTM C1852-2017 Standard Guide for Product Selection Delivery Systems for Aerosol Foam Sealants and Adhesives《气溶胶泡沫密封剂和粘合剂的产品选择 输送系统标准指南》.pdf
  • ASTM C1853-2017 Standard Test Method for The Determination of Carbon (Total) Content in Mixed Oxide ((U Pu)O2) Sintered Pellets by Direct Combustion-Infrared Detection Method《采用直接燃.pdf ASTM C1853-2017 Standard Test Method for The Determination of Carbon (Total) Content in Mixed Oxide ((U Pu)O2) Sintered Pellets by Direct Combustion-Infrared Detection Method《采用直接燃.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1