1、CMPTE STANDARD SMPTE 153-2001 Revision of ANSVSMPTE 153-1996 a for Motion-Picture Film (8-mm Type S) - - 16-mm Film Perforated 8-mm Type S (1 -4) - Printed Areas _ Page 1 of 2 pages 1 Scope This standard specifies the location and size of the printed picture area for negative/positive and reversal p

2、rnting operations on 16-mm motion-picture film per- forated 8-mm type s, 2R-1664 or 2R-1667, in row positions 1 and 4. 2 Dimensions 2.1 The dimensions shall be as given in figure 1 and table 1. 2.2 Dimension H is measured from the minus-2 perforation because this perforation position coincides with

3、the perforation used to position the resulting 8-mm print in the projector (see annex A.l). 2.3 Two images may be printed on this film. The image area on the left side, not shown in the figure, is symmetrical but opposite in direction to that shown on the right side. The dimensions for each image ar

4、ea, however, are taken from the nearest edge of the film as shown. NOTES 1 The reduction ratio of prints made from 16-mm negative or reversal originals shall be approximately 1.8:l. The cor- rect ratio is controlled by dimensions C and D. 2 The vertical dimension B of the reduced 8-mm type S image o

5、f the original camera aperture image should be nominally centered on the horizontal centerline of the per- foration although the exact location will be determined by dimension H and its tolerance. 3 The direction of film travel shown in figure 1 is to aid in illustrating the minus-2 perforation and

6、is the direction of motion in the projector for the resulting 8-mm print if the figure is as seen from the light source of a projector used for direct front projection. 4 If photographic audio is to be applied to the print, it is necessary to consider the required compatibility between this standard

7、 and the strong trade preference that a clear septum not appear between the edge of the printed picture and the edge of the printed track. This standard allows overlap (double) printing of adjacent areas of the printed picture and printed track without permitting undesirable incursions of one area i

8、nto the restricted area of the other. A suggested value of 0.0015 in (0.038 mm) more than minimum may be used. Copyright 8 2001 by THE SOCIEM OF MOTION PICTURE AND TELEVISION ENGINEERS 595 W. HaMale Ave, white Plains, NY 10607 (014) 761-1 1 w) Approved June 6,2001 SMPTE 153-2001 ROW 4 C- -2 PERFORAT

9、ION FOR FILM POSlTION o n 0 + -I PERFORATION e EITHER EDGE E + -0 PERFORATION 1 Figure 1 - Dimensions Table 1 - Specifications DIRECTION OF FILM TRAVEL 1 Dimensions Inches Millimeters A B C H R D) 0.228 re 5.79 ref 0.163 min 4.14 min 0.058 max 1.47 max 0.282 min 7.16 min 0.393 f 0.002 9.98 f 0.05 0.

10、005 max 0.13 max ) See note 4. Annex A (informative) Additional data Al If prints are made with a step printer, the registration device should be in the minus-2 perforation, or that perfora- tion which corresponds to the minus-2 perforation when the final print stage is reached, to obtain maximum be

11、nefit of cancellation as films are projected in accordance with ANSIISMPTE 154, which specifies the minus-2 perforation for projected films. A2 The parenthetical numerals have been added to the title of this standard to specify how the rows of perforations are Annex B (informative) Bibliography ANSI

12、ISMPTE 154-1998, Motion-Picture Film (8-mm Type S) - Projectable Image Area and Projector Usage placed on the film. This designation is necessary only when the film stock is wider than its end use and more than one combination of perforation rows is possible. The perforation rows are numbered starti

13、ng at the reference edge, which is the edge nearest to that row of perforations which is retained in the slitting operation. The row of perforations which is discarded is given the number O. Negative or intermediate films which are not slit may contain a O-numbered row of perforations if that perforated row corresponds to the dis- card row of perforations on the subsequent print stock. SMPTE 157-1999, Motion-Picture Film (8-mm Type S) - Camera Aperture Image and Usage ANSIISMPTE 168-1996, Motion-Picture Film (16-mm) - Perforated 8-mm Type S, (1-4) Page 2 of 2 pages

展开阅读全文
相关资源
猜你喜欢
  • DL 5068-2014 Code for design of chemistry of power plant《发电厂化学设计规范》.pdf DL 5068-2014 Code for design of chemistry of power plant《发电厂化学设计规范》.pdf
  • DL 5077-1997 Specifications for load design of hydraulic structures《水工建筑物荷载设计规范》.pdf DL 5077-1997 Specifications for load design of hydraulic structures《水工建筑物荷载设计规范》.pdf
  • DL 508-1993 Technical regulations for ordering AC 110~330kV self-contained oil-impregnated cables and their accessories《交流110~330kV自容式充油电缆及其附件订货技术规范》.pdf DL 508-1993 Technical regulations for ordering AC 110~330kV self-contained oil-impregnated cables and their accessories《交流110~330kV自容式充油电缆及其附件订货技术规范》.pdf
  • DL 509-1993 Technical regulations for ordering AC 110kV XLPE insulated cables and their accessories《交流110kV交联聚乙烯绝缘电缆及其附件订货技术规范》.pdf DL 509-1993 Technical regulations for ordering AC 110kV XLPE insulated cables and their accessories《交流110kV交联聚乙烯绝缘电缆及其附件订货技术规范》.pdf
  • DL 5162-2013 Technical specification of safety and protection facility for hydropower and water resources construction《水电水利工程施工安全防护设施技术规范》.pdf DL 5162-2013 Technical specification of safety and protection facility for hydropower and water resources construction《水电水利工程施工安全防护设施技术规范》.pdf
  • DL 5190 1-2012 The technical specification for electric power construction - Part 1 Civil structure work《电力建设施工技术规范 第1部分:土建结构工程》.pdf DL 5190 1-2012 The technical specification for electric power construction - Part 1 Civil structure work《电力建设施工技术规范 第1部分:土建结构工程》.pdf
  • DL 5190 2-2012 Technical specification for thermal power erection and construction Part 2 boiler unit 《电力建设施工技术规范 第2部分:锅炉机组》.pdf DL 5190 2-2012 Technical specification for thermal power erection and construction Part 2 boiler unit 《电力建设施工技术规范 第2部分:锅炉机组》.pdf
  • DL 5190 3-2012 Technical specification for thermal power erection and construction - Part 3 Steam turbine generator unit《电力建设施工技术规范 第3部分:汽轮发电机组》.pdf DL 5190 3-2012 Technical specification for thermal power erection and construction - Part 3 Steam turbine generator unit《电力建设施工技术规范 第3部分:汽轮发电机组》.pdf
  • DL 5190 4-2012 Technical specification for thermal power erection and construction - Part 4 Instrumentation and control《电力建设施工技术规范 第4部分:热工仪表及控制装置》.pdf DL 5190 4-2012 Technical specification for thermal power erection and construction - Part 4 Instrumentation and control《电力建设施工技术规范 第4部分:热工仪表及控制装置》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1