SMPTE ST 87M-1996 Motion-Picture Film (16-mm) - 100-Mil Magnetic Striping.pdf

上传人:eastlab115 文档编号:1047082 上传时间:2019-03-27 格式:PDF 页数:2 大小:74.83KB
下载 相关 举报
SMPTE ST 87M-1996 Motion-Picture Film (16-mm) - 100-Mil Magnetic Striping.pdf_第1页
第1页 / 共2页
SMPTE ST 87M-1996 Motion-Picture Film (16-mm) - 100-Mil Magnetic Striping.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 SMPTE 87M 96 m 8357YOL 0002373 122 m SMPTE STANDARD for Motion-Picture Film (1 6-mm) - 100-Mil Magnetic Striping ANSVSMPTE 87M-1996 Revision of ANSVSMPTE 87M-1991 1 Scope This standard specifies the location and dimensions of the magnetic striping material applied to 16-mm motion-picture film, whic

2、h is used for both picture and sound. 2 Normative reference The following standard contains provisions which, through reference in this text, constitute provisions of this standard. At the time of publication, the edition indicated was valid. All standards are subject to revi- sion, and parties to a

3、greements based on this stand- ard are encouraged to investigate the possibility of applying the most recent edition of the standard indi- cated below. ANSVSMPTE 109-1 992, Motion-Picture Film (1 6- mm) - Perforated 1 R and 2R Page 1 of 2 pages 3 Magnetic striping 3.1 The location and dimensions of

4、the magnetic striping shall be as given in figure 1 and table 1. 3.2 The magnetic striping material shall be on the side of the film toward the lamp on a projec- tor arranged for direct projection on a reflection- type screen. 4 Film stock The film stock used shall be safety type, cut and perforated

5、 in accordance with ANSI/SMPTE 109. 5 Balance stripe If the stripe is raised significantly (greater than 0.1 mil), then a balance stripe is required. The balance stripe need not be a continuous magnetic coating. CAUTION NOTICE This Standard may be revised or withdrawn at any time The procedures of t

6、he Standard Developer require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication Purchasers of standards may receive current information on all standards by calling or writing the Standard Developer Printed in USA Copyright O 199

7、6 by THE SOCIETY OF L American National Standard MOTION PICTURE AND TELEVISION ENGINEERS 595 W. Harisdale Ave., Whrte Plains, NY 10607 (914) 761-1100 Approved March 8, 1996 SMPTE 87M 96 m 8357401 0002374 Ob9 M ANSVSMPTE 87M-1996 MAGNETiC- STRIPE Figure 1 - Magnetic striping location Table 1 - Specif

8、ications Dimensions Mi I I i mete rs Inches A 15.95 ref 0.628 ref IB IC + 0.00 13.25 - 0.15 + 0.00 o8o - 0.15 + 0.000 - 0.006 + 0.000 - 0.006 D 0.15 rnax 0.006 max F 15.80 min 0.622 min Annex A (informative) Application The outer edge of both stripes ideally should be coincident with the edge of the film. Page 2 of 2 pages

展开阅读全文
相关资源
猜你喜欢
  • ONORM S 5233-1987 Dosimeters for use in radiotherapy with ionization Chambers forX-rays y -rays and electron beams《用于X射线,Y射线和电子光束的电离室放疗的剂量计》.pdf ONORM S 5233-1987 Dosimeters for use in radiotherapy with ionization Chambers forX-rays y -rays and electron beams《用于X射线,Y射线和电子光束的电离室放疗的剂量计》.pdf
  • ONORM S 5234-2-2001 Clinical dosimetry - Determination of the characteristic dose rate in brachytherapy with sealed gamma sources《临床剂量 密封伽玛源近距放射疗法的剂量率特性测定》.pdf ONORM S 5234-2-2001 Clinical dosimetry - Determination of the characteristic dose rate in brachytherapy with sealed gamma sources《临床剂量 密封伽玛源近距放射疗法的剂量率特性测定》.pdf
  • ONORM S 5234-3-2001 Clinical dosimetry - lonization chamber dosimetry《临床剂量 电离室剂量》.pdf ONORM S 5234-3-2001 Clinical dosimetry - lonization chamber dosimetry《临床剂量 电离室剂量》.pdf
  • ONORM S 5235-1998 Clinical dosimetry - Brachytherapy with sealed gamma sources《临床剂量 密封伽玛源近距放射疗法》.pdf ONORM S 5235-1998 Clinical dosimetry - Brachytherapy with sealed gamma sources《临床剂量 密封伽玛源近距放射疗法》.pdf
  • ONORM S 5237-1-1998 Radiation protection dosimeters - Personal dosimeters for the measurement of the personal dose equivalent Hp (10)resp Hp(0 07)《辐射防护剂量计    测量个人剂量当量 Hp (10) 和 Hp(.pdf ONORM S 5237-1-1998 Radiation protection dosimeters - Personal dosimeters for the measurement of the personal dose equivalent Hp (10)resp Hp(0 07)《辐射防护剂量计 测量个人剂量当量 Hp (10) 和 Hp(.pdf
  • ONORM S 5237-2-1998 Radiation protection dosimeters - Area dosimeters for the mesasurement of the ambient and directional dose equivalent resp dose equivalent rate《辐射防护剂量计 用于环境和定向剂.pdf ONORM S 5237-2-1998 Radiation protection dosimeters - Area dosimeters for the mesasurement of the ambient and directional dose equivalent resp dose equivalent rate《辐射防护剂量计 用于环境和定向剂.pdf
  • ONORM S 5240-1-1998 Image quality assurance in X-ray diagnostics - General conditions《X射线诊断图像质量保证 一般条件》.pdf ONORM S 5240-1-1998 Image quality assurance in X-ray diagnostics - General conditions《X射线诊断图像质量保证 一般条件》.pdf
  • ONORM S 5240-10-1998 Image quality assurance in X-ray diagnosis - Acceptancetesting in radiographic and fluoroscopic X-ray Systems《X射线诊断图像质量保证 射线检查和荧光检查X射线的验收测试》.pdf ONORM S 5240-10-1998 Image quality assurance in X-ray diagnosis - Acceptancetesting in radiographic and fluoroscopic X-ray Systems《X射线诊断图像质量保证 射线检查和荧光检查X射线的验收测试》.pdf
  • ONORM S 5240-11-1998 Image quality assurance in X-ray diagnosis - Acceptance testing of dental radiographic equipment - Rules for the inspection of image quality after installation.pdf ONORM S 5240-11-1998 Image quality assurance in X-ray diagnosis - Acceptance testing of dental radiographic equipment - Rules for the inspection of image quality after installation.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1