UL 224 CRD-2017 UL Standard for Safety Extruded Insulating Tubing Section Paragraph Reference (New) Section 5 A and Clause 5 A 1 Subject (Edition 6 March 6 2006).pdf

上传人:confusegate185 文档编号:1067873 上传时间:2019-04-02 格式:PDF 页数:2 大小:27.96KB
下载 相关 举报
UL 224 CRD-2017 UL Standard for Safety Extruded Insulating Tubing Section  Paragraph Reference (New) Section 5 A and Clause 5 A 1 Subject (Edition 6 March 6 2006).pdf_第1页
第1页 / 共2页
UL 224 CRD-2017 UL Standard for Safety Extruded Insulating Tubing Section  Paragraph Reference (New) Section 5 A and Clause 5 A 1 Subject (Edition 6 March 6 2006).pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): YDPU2/8, YDQS2, YDTU2 and YDSW2Standard Number: UL 224Standard Title: Standard for Extruded Insulating TubingEdition Date: March 6, 2006Edition Number: 6Section / Paragraph Reference: (New) Section 5.

3、A and Clause 5.A.1Subject:DECISION:New Section 5.A and Clause 5.A.15.A Pre-Conditioning and Test Conditions5.A.1 Unless otherwise specified all testing, except flammability, shall be conducted at 235C (739F)and a relative humidity of 5010% RH. Flammability testing shall be conducted in still air at

4、a temperatureof 15 35C (59 95F) and a relative humidity of 75%. All samples shall be preconditioned at 235C(739F) and a relative humidity of 5010% for a minimum of 30 minutes prior to test.RATIONALE FOR DECISION:It has come to ULs attention that specific preconditions and test conditions are not des

5、cribed in all cases.The addition of Section 5.A and Clause 5.A.1 are intended to define these parameters.Copyright 2017 UL LLCUL LLC, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or tha

6、t they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the standard. They do not represent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL LLC shal

7、l not be responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyobligation or liability for damages, including consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decision

8、s. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSTANDARD NUMBER: UL 224 -2-No Text on This Page

展开阅读全文
相关资源
猜你喜欢
  • GOST R ISO IEC 15504-4-2012 Information technology Process assessment Part 4 Guidance on use for process improvement and process capability determination《信息技术 过程评估 第4部分 用于过程改进和过程容量.pdf GOST R ISO IEC 15504-4-2012 Information technology Process assessment Part 4 Guidance on use for process improvement and process capability determination《信息技术 过程评估 第4部分 用于过程改进和过程容量.pdf
  • GOST R ISO IEC 15693-1-2013 Identification cards Contactless integrated circuit cards Vicinity cards Part 1 Physical characteristics《识别卡 无触点的集成电路卡 临近式卡 第1部分 物理特性》.pdf GOST R ISO IEC 15693-1-2013 Identification cards Contactless integrated circuit cards Vicinity cards Part 1 Physical characteristics《识别卡 无触点的集成电路卡 临近式卡 第1部分 物理特性》.pdf
  • GOST R ISO IEC 15693-2-2013 Identification cards Contactless integrated circuit cards Vicinity cards Part 2 Air interface and initialization《识别卡 无触点的集成电路卡 临近式卡 第2部分 空中接口和初始化》.pdf GOST R ISO IEC 15693-2-2013 Identification cards Contactless integrated circuit cards Vicinity cards Part 2 Air interface and initialization《识别卡 无触点的集成电路卡 临近式卡 第2部分 空中接口和初始化》.pdf
  • GOST R ISO IEC 15693-3-2011 Identification cards Contactless integrated circuit cards Vicinity cards Part 3 Anticollision and transmission protocol《识别卡 非接触式集成电路卡 邻近卡 第3部分 防碰撞和传输协议》.pdf GOST R ISO IEC 15693-3-2011 Identification cards Contactless integrated circuit cards Vicinity cards Part 3 Anticollision and transmission protocol《识别卡 非接触式集成电路卡 邻近卡 第3部分 防碰撞和传输协议》.pdf
  • GOST R ISO IEC 15910-2002 Information technology Software user documentation process《信息技术 软件用户文献处理》.pdf GOST R ISO IEC 15910-2002 Information technology Software user documentation process《信息技术 软件用户文献处理》.pdf
  • GOST R ISO IEC 17007-2011 Conformity assessment Guidance for drafting normative documents suitable for conformity assessment《合格评定 合格评定用规范性文件的编写指南》.pdf GOST R ISO IEC 17007-2011 Conformity assessment Guidance for drafting normative documents suitable for conformity assessment《合格评定 合格评定用规范性文件的编写指南》.pdf
  • GOST R ISO IEC 17020-2012 Conformity assessment Requirements for the operation of various types of bodies performing inspection《合格评定 各类检查机构的运作要求》.pdf GOST R ISO IEC 17020-2012 Conformity assessment Requirements for the operation of various types of bodies performing inspection《合格评定 各类检查机构的运作要求》.pdf
  • GOST R ISO IEC 17030-2007 General requirements for third party marks of conformity《一致性的第三方符合性标志的通用要求》.pdf GOST R ISO IEC 17030-2007 General requirements for third party marks of conformity《一致性的第三方符合性标志的通用要求》.pdf
  • GOST R ISO IEC 17065-2012 Conformity assessment Requirements for bodies certifying products processes and services《合格评定 产品 工艺和服务认证机构要求》.pdf GOST R ISO IEC 17065-2012 Conformity assessment Requirements for bodies certifying products processes and services《合格评定 产品 工艺和服务认证机构要求》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1