UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf

上传人:progressking105 文档编号:1068226 上传时间:2019-04-02 格式:PDF 页数:4 大小:25.53KB
下载 相关 举报
UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section  Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf_第1页
第1页 / 共4页
UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section  Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf_第2页
第2页 / 共4页
UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section  Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf_第3页
第3页 / 共4页
UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section  Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a

2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): AXUT, RTRTStandard Number: UL 498Standard Title: Standard for Attachment Plugs and ReceptaclesEdition Date: March 30, 2012Edition Number: 15Section / Paragra

3、ph Reference: (New ) Supplement SHSubject: MAGNETICALLY COUPLED CORD CONNECTOR AND INLETDECISION:Addition of new requirements to UL 498 the Standard for Attachment Plugs and Receptacles, SupplementSH Magnetically Coupled Cord connector and Inlet.SUPPLEMENT SH MAGNETICALLY COUPLED CORD CONNECTOR AND

4、INLET :INTRODUCTIONSH1 ScopeSH1.1 The requirements of this supplement cover a magnetically coupled cord connector and inletintended to facilitate the extension of a branch circuit for use with a motor vehicle engine block heater orother electrical utilization equipment, in accordance with the Nation

5、al Electrical Code, NFPA 70.SH1.2 These devices are intended for use with copper conductors only.SH1.3 These devices are only intended for use on 15- or 20-Ampere, 125-V AC only branch circuits.SH2 GlossarySH2.1 For the purpose of this supplement, the following definitions apply.SH2.2 MAGNETICALLY C

6、OUPLED CORD CONNECTOR - A female contact device to be wired onflexible cord for use as an extension from an outlet to make a detachable electrical connection.Connection to inlet is held by a permanent magnet.SH2.3 MAGNETICALLY COUPLED INLET - A male contact device to be wired on flexible cord to pro

7、videan integral blade configuration for the connection of a cord connector. Connection to cord connector isheld by a permanent magnet.SH2.4 MAGNETICALLY COUPLED CONNECTOR ASSEMBLY Devices constructed of two matedhalves (i.e. cord connector and inlet) held together by a permanent magnetSH2.5 OMNIPOLA

8、R IC SWITCH (Hall or Reed Switch) - A hall or reed IC switch that operates with thedetection of a magnetic field.CONSTRUCTIONUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSH3 GeneralSH3.1 In addition to the construction, performance and mark

9、ing requirements contained in this Standard,a magnetically coupled cord connector and inlet shall also comply with the applicable requirements for itsindividual parts as described in Sections SH3.2 SH11.1.SH3.2 The magnetically coupled cord connector assembly shall be constructed so that voltage,amp

10、erage, device configuration and polarity are consistent throughout the complete assembly.SH3.3 A magnetically coupled connector assembly shall have only one outlet supplied from one set of lineblades.SH4 Electrical RatingSH 4.1 A magnetically coupled cord connector assembly shall be rated either 15

11、A, 125 V AC or 20 A,125 V AC only.SH5 Accessibility of Live PartsSH5.1 Accessibility of live parts shall comply with UL 498 para. 9.1.4 in both the coupled and uncoupledpositions. Magnetically coupled connector assembly shall not be relied upon to provide and render parts“de-energized”.Exception: Pe

12、rmanent magnets used in combination with electronic circuitry may be used to render parts“de-energized” provided such electronic circuitry complies with the Standard for Safety-Related ControlsEmploying Solid-State Devices, UL 991. If the computational investigation is conducted, the maximumfailure

13、rate (l) shall not exceed 1.5 failures per million hours. If the demonstrated method is conducted,the test acceleration multiplier shall be 5763.SH6 Environmental ProtectionSH6.1 A magnetically coupled cord connector assembly shall be marked with a Type designation andcomply with the one of the Type

14、 designation identified in UL 498 Supplement SB Enclosure Types forEnvironmental Protection.SH6.2 A magnetically coupled cord connector assembly that is provided with a spring-closing cover shallalso comply with the Spring-Closing Cycling test as described in SH10.SH7 Internal Splices and Connection

15、sSH7.1Internal splices and connections shall be mechanically secure and shall provide electrical continuitywithout strain on connections and terminals.SH7.2 A soldered connection shall be made mechanically secure before being soldered.PERFORMANCESH8 GeneralSH8.1 A magnetically coupled cord connector

16、 assembly shall be subjected to all tests for a cord connectorand inlet, respectively, as identified in this Standard.STANDARD NUMBER: UL 498 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSH8.2 In addition to SH8.1, a magnetically coupled

17、 cord connector assembly shall be subjected to testsas described in SH8.3 through SH10.SH8.3 The switching means of a magnetically coupled cord connector assembly shall also comply withthe Contact Gap, Overload, Endurance No. 1 (Inductive - 6000 cycles), Endurance No. 2 (Tungsten - 6000cycles), Temp

18、erature, and Contact Gap (repeated) tests contained in the Standard for Flush Switches, UL20. These tests shall be performed based upon the marked ampere and voltage rating of the magneticallycoupled cord connector assembly.SH9 Component Failure TestSH9.1 A magnetically coupled cord connector assemb

19、ly shall not become a shock or fire hazard whenoperating while in an abnormal condition, such as with a short-circuited or open-circuited component.Each component whose failure can result in a likelihood of risk of electric shock, risk of fire, or both, shallbe tested by imposing a fault on the comp

20、onent which simulates the typical failure mode for thecomponent. Examples of failure modes may include: diodes fail open or short circuit, electrolyticcapacitors fail open circuit, or partial short circuit.SH9.2 A single layer of cheesecloth is to be loosely draped over the magnetically coupled cord

21、 connectorassembly. A 1-A fuse is to be connected between the grounded supply conductor and accessibleconductive parts of the device.SH9.3 The cheesecloth mentioned in SH9.2 shall be bleached cheesecloth running approximately 26 - 28square meters per kilogram mass (14 - 15 square yards per pound mas

22、s), and having for any squarecentimeter, 13 threads in one direction and 11 in the other direction (what is known in the trade as acount of 32 by 28, that is, for any square inch, 32 threads in one direction and 28 threads in the otherdirection).SH9.4 A magnetically coupled cord connector assembly o

23、perating under abnormal conditions will beconsidered to have become a hazard if:a) There is glowing or flaming of the cheesecloth mentioned in SH9.2, orb) There is emission of molten metal, orc) The fuse mentioned in SH9.2 operates to open the circuit, ord) It is possible to touch an energized part

24、with the articulated probe shown in Figure 9.1, ore) There is any other evidence of hazard.SH10 Spring-Closing Cycling TestSH10.1 When subjected to the cycling test described in SH10.2 a spring-closing cover shall not crack,deform, or otherwise be damaged so as to allow the entrance of water as veri

25、fied by the appropriateenvironmental test as described in UL 498 Supplement SB Enclosure Types for EnvironmentalProtection.SH10.2 A spring-closing cover shall be subjected to 1000 cycles of operation. One cycle of operation isconsidered to be complete opening of the cover followed by allowing the co

26、ver to assume its naturalposition.MARKINGS AND INSTRUCTIONSSTANDARD NUMBER: UL 498 -3-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSH11 Markings and Installation InstructionsSH11.1 In addition to the marking and installation instruction req

27、uirements contained in this Standard, amagnetically coupled cord connector assembly shall also be marked with a Type designation, see SH6.1.RATIONALE FOR DECISION:In addition to the applicable requirements for a cord connector and inlet contained in this Standard, amagnetically coupled cord connecto

28、r and inlet shall also comply with the applicable requirements for itsindividual parts as described in this new Supplement SH .Copyright 2014 Underwriters Laboratories Inc.UL, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification

29、 Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of Underwriters Laboratories Inc. inpractically applying the requirements of the standard. They do not represent formal interpretations of thestandard under Am

30、erican National Standards Institute (ANSI) processes. UL shall not be responsible toanyone for the use of or reliance upon Certification Requirement Decisions by anyone. UL shall not incurany obligation or liability for damages, including consequential damages, arising out of or in connectionwith the use or reliance upon Certification Requirement Decisions. The electronic version of theCertification Requirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 498 -4-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1