1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): AFFT/7Standard Number: UL 60335-2-40Standard Title: Standard for Particular Requirements for Electrical Heat Pumps,Air-Conditioners and DehumidifiersEdition Date: November 30, 2012Edition Number: 1Sec

3、tion / Paragraph Reference: 19.101DV, 22.112DV.18, 30.2.3DVSubject:DECISION:19.101DV D2 - Modification by adding the following at the end of 19.101In appliances in which the compressor is enclosed in an unventilated enclosure where temperatures of theenclosure or components within the enclosure migh

4、t become a hazard upon loss of refrigerant flow, therefrigerant flow shall be reduced by removal of the refrigerant from the system.The test shall be conducted under each of the following conditions:- with 75% of the charge removed- with the system pressure less than 1.2 atm, but not less than 1.0 a

5、tm with the appliance de-energizedThe appliance shall be operated under the conditions of Clause 11 at the lower limit of the rated voltageand an ambient temperature of 23 C 5 C. The appliance shall be operated until all components andthe enclosure temperatures stabilize or are declining, but for no

6、t less than 24 hours, or until the operationof the compressor is terminated by a non-self-resetting protective device. Any self-resetting protectivedevices that actuates during this test shall be allowed to cycle as intended.Component temperatures shall:- not exceed the temperature limits in Clause

7、11- not exceed the relative thermal index of the material in accordance with UL746B and CAN/CSA C22.2No. 0.17 for polymeric materials22.112DV.18 Self-resetting protective devices which cycle during 19.101DV shall be rated for at least100,000 cycles for line break devices and 5,000 cycles for non-lin

8、e break.Note: There a number of solutions which may be effective in meeting the test criteria. For example; a)thermal based solutions such as electronic devices like a Heat Detector Circuit-Interrupters (HDCIs) orelectromechanical devices like bi-metal snap disc and similar thermal based devices, or

9、 b) refrigerantpressure sensitive devices.Compliance is checked by inspection and in case of doubt, the test shall be conducted.30.2.3DV D2 - Modification by adding the following:UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFor appliances i

10、n which the compressor is enclosed in an unventilated non-metallic enclosure, polymericmaterials of the enclosure and components within the enclosure shall be classified V-0 or higher accordingto IEC 60695-11-0.Compliance is checked by inspection.RATIONALE FOR DECISION:These requirements are necessa

11、ry due to the dehumidifier fires and CPSC recalls of the past severalyears. Similar requirements have already been added to UL 474, the Standard for Dehumidifiers, witheffective dates of February 6, 2017 and March 9, 2017. In addition, these requirements have beenincluded in the proposed 2nd edition

12、 of UL 60335-2-40. These dehumidifier-specific requirements havebeen balloted and have achieved consensus. However, it appears this 2nd edition will not be publishedfor at least several more months due to issues other than dehumidifiers. Because of the importance ofthese safety requirements, and the

13、 necessity of having dehumidifiers comply in a timely fashion, UL isadding them to the 1st edition via this CRD.Copyright 2016 UL LLCUL LLC, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue

14、 or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the standard. They do not represent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL L

15、LC shall not be responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyobligation or liability for damages, including consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 60335-2-40 -2-