UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf

上传人:syndromehi216 文档编号:1068577 上传时间:2019-04-02 格式:PDF 页数:19 大小:960.09KB
下载 相关 举报
UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf_第1页
第1页 / 共19页
UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf_第2页
第2页 / 共19页
UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf_第3页
第3页 / 共19页
UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf_第4页
第4页 / 共19页
UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf_第5页
第5页 / 共19页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 608 Burglary Resistant Vault Doors and Modular PanelsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUT

2、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Burglary Resistant Vault Doors and Modular Panels, UL 608 Seventh Edition, Dated November 30, 2004 Summary of Topics Revised 8.3.1 to show that door frame constructions, vestibules, and the like, n

3、eed to provide equivalent security protection as the vault door and connecting vault panel structures. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the

4、 margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated June 3, 2011. All rights reserved. No part of this pub

5、lication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not

6、 limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability

7、 to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards

8、 for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer s

9、ystem. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that

10、have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. The following table lists the future effective dates with the corresponding reference. MAY 31, 2012 UL 608 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBU

11、TION WITHOUT PERMISSION FROM UL Future Effective Dates References The effective date for the revised requirement is to be determined. 8.3.1 MAY 31, 2012 UL 608 tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 30, 2004 (Title Page

12、Reprinted: May 31, 2012) 1 UL 608 Standard for Burglary Resistant Vault Doors and Modular Panels The rst and second editions were titled Burglary Resistant Vault Doors. First Edition April, 1980 Second Edition January, 1982 Third Edition July, 1982 Fourth Edition August, 1988 Fifth Edition September

13、, 1994 Sixth Edition March, 1999 Seventh Edition November 30, 2004 This ANSI/UL Standard for Safety consists of the Seventh Edition including revisions through May 31, 2012. The most recent designation of ANSI/UL 608 as an American National Standard (ANSI) occurred on May 31, 2012. ANSI approval for

14、 a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards D

15、evelopment System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property

16、 of UL. COPYRIGHT 2012 UNDERWRITERS LABORATORIES INC. ANSI/UL 608-2012UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 2 No Text on This PageUL COPYRIGHTED MATERIAL

17、NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 2.1 Components .5 2.2 Units of measurement .6 2.3 Undated references .6 3 Glossary .6 CONSTRUCTION 4 Corrosion Protection .7 5 Locks 7 PERFORMANCE 6 General 8 7 Test Equipm

18、ent .8 8 Attack Tests 8 8.1 General .8 8.2 Lock mechanism .9 8.3 Cutting an opening .9 8.4 Cutting locking bolts 9 MARKING 9 Details .9 APPENDIX A Standards for Components .A1 NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR

19、THER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 31, 2012 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover vault doo

20、rs and vault modular panels (for use in the construction of vault oors, walls, and ceilings) of the type intended for use in nancial institutions, commercial, industrial and mercantile properties, and the like, and that are relied upon to protect the contents from burglary attack. 1.2 These requirem

21、ents are intended to establish the burglary resistant rating of vault doors and modular panels according to the length of time they withstand attack by common mechanical tools, electric tools, cutting torches, or any combination of these means. The ratings based on the net working time to effect ent

22、ry are as follows: a) Class M 1/4 hour. b) Class 1 1/2 hour. c) Class21hour. d) Class32hours. 1.3 These requirements do not cover attacks with the burning bar (thermal lance) or explosives. 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard

23、 shall comply with the requirements for that component. See Appendix A for a list of standards covering components used in the products covered by this standard. 2.1.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the ap

24、plication of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.1.4 Specic components are incomplete in construction features or

25、restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 5U

26、L COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2 Units of measurement 2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.3 Undated references 2.3.1 Any undated r

27、eference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 3 Glossary 3.1 For the purpose of this standard the following denitions apply. 3.2 COMMON HAND TOOLS Chisels, punches, wrenches, screwdriver

28、s, pliers, hammers, and sledges not exceeding the 8-pound (3.6 kg) size, and pry bars and ripping tools not exceeding 5 feet (1.52 m) in length. 3.3 CUTTING TORCH A heavy-duty, commercially available oxy-fuel cutting torch. 3.4 ENTRY Opening the door or making a 96-square-inch (619-cm 2 ) opening en

29、tirely through the door or door frame or both, including the grouted-in portion within the frame, or through the modular panel or a seam joining two or more modular panels. 3.5 FLUXING ROD Low carbon steel or similar type material rods, such as concrete reinforcing rods, to aid in torch cutting. 3.6

30、 HYDRAULIC TOOLS Portable electric or manually operated jacks, wedges, and similar pressure applying devices not exceeding 100,000 pounds (444,820 N) of force. 3.7 IMPACT TOOLS Portable electric or pneumatic impact hammers and hammer drills, not exceeding the 1 inch (25.4 mm) chuck size. 3.8 NET WOR

31、KING TIME The time during which an attack is actively in progress on the sample, excluding the time required for test preparation, safety precautions, and delays. 3.9 96-SQUARE-INCH OPENING A rectangular-shaped opening with the smallest dimension being 6 inches (152 mm), a circular opening 11.06 inc

32、hes (281 mm) in diameter, or an isosceles right-triangle- shaped opening with a hypotenuse of 19.6 inches (497 mm). 3.10 PICKING TOOLS Common or stranded patterns that are not designed for use against a specic model of vault door. 3.11 PORTABLE ELECTRIC DRILLS AND TOOLS Electric hand drills accommod

33、ating drill bits not larger than 1 inch (25.4 mm) and coring drills. 3.12 POWER SAWS Circular saws not exceeding 8 inches (203 mm) in diameter, hole saws not exceeding 12 inches (305 mm) in diameter, or reciprocating saws. 3.13 PRESSURE APPLYING DEVICES Portable drill presses, portable drilling jigs

34、, or other types of drill-holding mechanisms. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONSTRUCTION 4 Corrosion Protection 4.1 Iron and steel parts, other t

35、han bearings, and the like, shall be protected against corrosion by enameling, galvanizing, sherardizing, plating, or other means determined to be equivalent. Exception No. 1: This requirement does not apply to parts, such as washers, screws, bolts, and the like, if corrosion of such unprotected par

36、ts would not impair the intended operation of the unit. Exception No. 2: Parts made of stainless steel, polished or treated, if necessary, do not require additional protection against corrosion. Exception No. 3: This requirement does not apply to reinforcing elements used to strengthen concrete and

37、the like. 4.2 The requirement in 4.1 applies to all enclosures of sheet steel or cast iron, and to all springs and other parts upon which intended mechanical operation or construction depends. Bearing surfaces shall resist binding due to corrosion. 4.3 Metal shall not be used in combinations that ca

38、use galvanic action. Exception: If galvanic action does not result in impaired operation of construction of the product or impaired security, this requirement does not apply. 5 Locks 5.1 Each vault door shall be provided with: a) A combination lock classied as Group 1 or 1R complying with the Standa

39、rd for Combination Locks, UL 768, or a high-security electronic lock, Type 1, complying with the requirements for high-security electronic locks; or b) A timelock complying with the Standard for Delayed-Action Timelocks, UL 887, and a combination lock classied as Group 1, 1R, or 2M, complying with U

40、L 768; or c) A timelock complying with UL 887, and a high-security electronic lock, Type 1, complying with the requirements for high-security electronic locks. Exception: The door is not required to be shipped with the timelock mounted to it when the door is fully prepared for the mounting of the ti

41、melock and the timelock is shipped with the door in separate packaging. A prominent marking shall be attached to the door informing the installer of the door that the timelock shall be installed in order to provide the intended locking security. Instructions for the mounting of the timelock shall be

42、 shipped with the door and the timelock. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PERFORMANCE 6 General 6.1 A single sample that is fully representative of

43、a series of vault doors of similar design, size and construction, shall be submitted for test. 6.2 At least two or more modular vault panels shall be submitted to represent the specied design of the vault and assembled to represent all seams used to construct the oor, walls and ceiling of the vault.

44、 6.3 The selection of test samples shall be determined by a study of detailed dimensioned drawings of the construction and schedule of sizes, and specications of the steel and drill-resistant and torch-resistant metal or materials shall be furnished. 6.4 The door and seam clearances of the test samp

45、le shall represent the manufacturers maximum production tolerances. 7 Test Equipment 7.1 The test equipment shall include any common hand tools, picking tools, mechanical or portable electric tools, grinding points carbide drills, pressure applying devices or mechanisms, abrasive cutting wheels, pow

46、er saws, coring tools, impact tools, uxing rods, and oxy-fuel gas cutting torches. 7.2 The quantity of gas consumed (combined total oxygen and fuel gas) in any one test shall be limited as follows: a) Class M and 1 2000 ft 3 (56.6 m 3 ). b) Class 2 4000 ft 3 (113.3 m 3 ). c) Class 3 8000 ft 3 (226.5

47、 m 3 ). 8 Attack Tests 8.1 General 8.1.1 The testing party, consisting of two skilled operators, may select any or all of the methods of attack and may sustain each attack for the full allotted time. The product shall resist the best method or combination of methods applied to a given point or area

48、for the net working time specied. NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 8.2 Lock mechanism 8.2.1 An attempt is to be made to penetrate through the door t

49、o the lock box, lug, carrying bar, or other parts of the mechanism, then to release the boltwork by punching, prying, picking, or cutting. 8.3 Cutting an opening 8.3.1 An attempt is to be made to cut an opening 96 square-inches (619 cm 2 ) entirely through the door, the door frame, vestibule, a modular panel, or at a seam joining two or more modular panels. 8.3.1 revised, effective date to be determined 8.4 Cutting locking bolts 8.4.1 An attempt is to be made to cut as