UL 634 CRD-2013 UL Standard for Safety Connectors and Switches for Use with Burglar-Alarm Systems - Section Paragraph Reference Sections 19 2 and 64 Subject Operating Gap C All Swi.pdf

上传人:arrownail386 文档编号:1068779 上传时间:2019-04-02 格式:PDF 页数:2 大小:12.73KB
下载 相关 举报
UL 634 CRD-2013 UL Standard for Safety Connectors and Switches for Use with Burglar-Alarm Systems - Section Paragraph Reference Sections 19 2 and 64 Subject Operating Gap C All Swi.pdf_第1页
第1页 / 共2页
UL 634 CRD-2013 UL Standard for Safety Connectors and Switches for Use with Burglar-Alarm Systems - Section Paragraph Reference Sections 19 2 and 64 Subject Operating Gap C All Swi.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a

2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): AMQV, AMQV2Standard Number: UL 634Standard Title: Standard for Connectors and Switches for Use with Burglar-AlarmEdition Date: October 12, 2007Edition Number

3、 9Section / Paragraph Reference: Sections 19.2 and 64Subject: Operating Gap All SwitchesDECISION:All UL 634 switches must meet the minimum operating gap of 1/8 inch (3.2 mm) specified in section 19in addition to the specific requirements of sections 49 65 for Level 1 and Level 2 switches. Clarifyin

4、gstatements are shown in strike through and underlined text.19 Operation Test19.1 General19.2 Magnetically actuated switches19.2.1 Magnetically actuated switches intended for installation on magnetic materials shall operate asintended with a gap of 1/8 inch (3.2 mm) or more between the magnet and th

5、e switch housings when bothhousings are mounted on a 1/4 inch (6.4 mm) thick mild steel plate as intended in service.19.2.1.1 Level 1 and Level 2 high security switches shall have an operational gap of 1/8 in. (3.2 mm) inaddition to complying with the applicable requirements specified in Sections 49

6、 65.19.2.2 As the maximum acceptable gap of separation is based upon the parameters of field installation,the gap of separation of unmounted samples of each magnetically actuated switch construction is to bemeasured on nonmagnetic material for informational purposes. The gap of separation is the dis

7、tancebetween the magnet and switch housings at the point where the magnet releases the switch mechanism.64 Foreign Magnetic Field Compromise Tests64.3 For the SMT test magnet and shunt selection:a) The MOG equals the open air distance from the surface of the BMS switch to the actuator,and shall be a

8、djusted to its maximum distance in accordance with the manufacturinginstructions. 1/8 inch (3.2 mm) operating gap (also reference 19.2.1).RATIONALE FOR DECISION:UL 634 performance tests are intended to be incremental in security with all switches meeting the generalrequirements of section 19, and in

9、cremental in performance to Level 1 then Level 2 (High SecurityBalanced Magnet Switches). These clarifications show that 1/8 inch (3.2 mm) operating gap applies to allswitches covered by this standard and manufacturers instructions are not allowed exceptions to the basicrequirements of the standard.

10、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCopyright 2013 Underwriters Laboratories Inc.UL, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions

11、 it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of Underwriters Laboratories Inc. inpractically applying the requirements of the standard. They do not represent formal interpretations of thestandard under American National Standa

12、rds Institute (ANSI) processes. UL shall not be responsible toanyone for the use of or reliance upon Certification Requirement Decisions by anyone. UL shall not incurany obligation or liability for damages, including consequential damages, arising out of or in connectionwith the use or reliance upon Certification Requirement Decisions. The electronic version of theCertification Requirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 634 -2-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1