UL 817-2015 UL Standard for Safety Cord Sets and Power-Supply Cords (Twelfth Edition Reprint with Revisions Through and Including May 5 2017)《电线集和电力供给电线》.pdf

上传人:王申宇 文档编号:1068959 上传时间:2019-04-02 格式:PDF 页数:190 大小:2.57MB
下载 相关 举报
UL 817-2015 UL Standard for Safety Cord Sets and Power-Supply Cords (Twelfth Edition Reprint with Revisions Through and Including May 5 2017)《电线集和电力供给电线》.pdf_第1页
第1页 / 共190页
UL 817-2015 UL Standard for Safety Cord Sets and Power-Supply Cords (Twelfth Edition Reprint with Revisions Through and Including May 5 2017)《电线集和电力供给电线》.pdf_第2页
第2页 / 共190页
UL 817-2015 UL Standard for Safety Cord Sets and Power-Supply Cords (Twelfth Edition Reprint with Revisions Through and Including May 5 2017)《电线集和电力供给电线》.pdf_第3页
第3页 / 共190页
UL 817-2015 UL Standard for Safety Cord Sets and Power-Supply Cords (Twelfth Edition Reprint with Revisions Through and Including May 5 2017)《电线集和电力供给电线》.pdf_第4页
第4页 / 共190页
UL 817-2015 UL Standard for Safety Cord Sets and Power-Supply Cords (Twelfth Edition Reprint with Revisions Through and Including May 5 2017)《电线集和电力供给电线》.pdf_第5页
第5页 / 共190页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 817 Cord Sets and Power-Supply CordsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTH

2、ER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Cord Sets and Power-Supply Cords, UL 817 Twelfth Edition, Dated March 11, 2015 SUMMARY OF TOPICS This revision of ANSI/UL 817 is being issued to incorporate the following changes: Addition of requirements to allow

3、the use of SPT-1W and SPT-2W for outdoor-use power-supply cords Revision to Table 10.15 to allow an adapter cord set with a 20 A attachment plug to have both 15 A and 20 A outlets Revision to Table 10.2, circuit-conductor ampacity and voltage rating for jacketed cords in extension cord sets and powe

4、r-supply cords Addition of requirements for rotating plugs Addition of requirements related to overcurrent protection on 18 and 17 AWG extension cord sets Addition of requirements to cover a construction of a general-use cord set employing a joint The new/revised requirements are substantially in ac

5、cordance with Proposal(s) on this subject dated July 10, 2015, September 4, 2015 and November 6, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwi

6、se without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, in

7、direct or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for

8、any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable

9、attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard havin

10、g future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 5, 2016 UL 817 tr1UL COPYRIGHTED M

11、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 5, 2016 UL 817 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 11, 2015 (Title Page Reprinted: January 5, 2016)

12、1 UL 817 Standard for Cord Sets and Power-Supply Cords The First edition was titled Standard for Cord Sets. First Edition October, 1937 Second Edition February, 1948 Third Edition May, 1952 Fourth Edition December, 1955 Fifth Edition June, 1962 Sixth Edition February, 1972 Seventh Edition December,

13、1977 Eighth Edition May, 1980 Ninth Edition December, 1986 Tenth Edition January, 1994 Eleventh Edition March, 2001 Twelfth Edition March 11, 2015 This ANSI/UL Standard for Safety consists of the Twelfth Edition including revisions through January 5, 2016. The most recent designation of ANSI/UL 817

14、as an American National Standard (ANSI) occurred on January 5, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a

15、 Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding th

16、ose Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 817-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MARCH 11, 2015 CORD SETS AND POWER-SUPPLY CORDS - UL 817 2 No Tex

17、t on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .8 2 Components 8 3 Units of Measurement .9 4 Undated References 9 5 Denitions .9 CONSTRUCTION 6 Fittings General 11 6.1 Congurations and dimensions

18、11 6.2 Flammability 12 6.3 Accessibility of live parts .12 6.4 Connection to ttings 14 6.5 Identication and wiring 14 6.6 Treatment of cord-conductor coverings .16 6.7 Outdoor-use ttings 16 7 Plugs .16 7.1 Plugs 16 7.2 Attachment plug grip .17 7.3 Hospital grade attachment plugs 20 8 Cord Connectors

19、 .21 8.1 General 21 8.2 Holes, indentations, and projections .23 8.3 Improper insertion .23 8.4 Mismating 23 8.5 Cord connector outdoor 25 8.6 Hospital grade connectors 26 9 Other Components .26 9.1 General 26 9.2 Metal strain relief clamps .26 9.3 Switches .27 9.4 Switches outdoor 27 9.5 Current ta

20、ps and pendant switches 28 9.6 Through-cord heating-pad switch 29 9.7 Fittings intended to accommodate overcurrent protective devices .29 9.8 Supplementary circuit 30 9.9 Devices employing remote control features .30 9.10 Overcurrent protection 31 9.11 Cord restraint devices .31 10 Assembly .32 10.1

21、 Power-supply cords .32 10.2 Special-use power-supply cords 39 10.3 Recreational vehicle power-supply cords 40 10.4 Mobile home power-supply cords .42 10.5 Range and dryer power-supply cords .43 10.6 Range and dryer power-supply cord kits 46 10.7 Extension cord sets 47 10.8 Adapter cord sets 60 MARC

22、H 11, 2015 CORD SETS AND POWER-SUPPLY CORDS - UL 817 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 10.9 Special-use cord sets .66 10.10 Vacuum cleaner and oor-nishing machine cord sets .69 10.11 Recreational vehicle cord sets 69 10.12 Hos

23、pital grade power-supply cords, extension cords, and cord sets .70 10.13 Cord sets with appliance plugs 71 10.14 Cord sets with atiron plugs 72 10.15 Cord sets for appliances rated 50 W or less 72 10.16 Replacement-use with nonstandard polarization .73 PERFORMANCE 11 Attachment plugs and cord connec

24、tors 73 11.1 Conductor secureness test 73 11.2 Security of insulation test 74 11.3 Strain relief test 74 11.4 Dielectric voltage-withstand test 78 11.5 Insulation resistance test 79 11.6 Accelerated aging test 79 11.7 Crushing test 80 11.8 Impact resistance test 80 11.9 Flexing test 82 11.10 Jacket

25、retention test .84 11.11 Adhesion test .85 11.12 Cycling heat test 85 12 Tests for Attachment Plugs 87 12.1 Security of blades and pins test 87 12.2 Temperature test .88 12.3 Plug grip test 88 12.4 Blade pull test at elevated temperature .92 12.5 Abrupt pull test .93 13 Tests for Range and Dryer Pow

26、er-Supply Cord Kits .97 13.1 Strain relief test 97 13.2 Accelerated aging test 99 13.3 Push-back force test .100 14 Tests for cord connectors .102 14.1 Depth of cavity test 102 14.2 Conditioning cycles for blade retention test .102 14.3 Retention of blades test 102 14.4 Overload test .105 14.5 Tempe

27、rature test 106 14.6 Retention of blades test (repeated) 107 14.7 Resistance to arcing test .107 14.8 Improper insertion test .107 14.9 Low-temperature insertion test 109 14.10 Random drop test 110 14.11 Closure of openings test 110 15 Tests for Flatiron and Appliance Plugs .111 16 Test for Permanen

28、ce of Warning Tag 111 16.1 Cords other than outdoor type 111 16.2 Outdoor-type (W) cords 111 16.3 Oil-resistant cords .112 16.4 Test procedure .112 16.5 Evaluation 112 MARCH 11, 2015 CORD SETS AND POWER-SUPPLY CORDS - UL 817 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIB

29、UTION WITHOUT PERMISSION FROM UL 17 Tests for Overcurrent Protective Devices .113 17.1 General 113 17.2 Calibration test 113 17.3 Short-circuit tests for all products with overcurrent protection .113 17.4 Short-circuit test for fuses 114 17.5 Abnormal test .114 17.6 Water exclusion test for enclosur

30、es of outdoor-use products 115 18 Hospital Grade Molded-On Plugs and Connectors .117 18.1 General 117 18.2 Strain relief tests 117 18.3 Bonding (grounding) pin retention hospital grade cord connector 120 18.4 Attachment plug connection and separation hospital grade cord connector .124 18.5 Grounding

31、 contact temperature hospital grade cord connector 124 18.6 Ground resistance hospital grade cord connector .125 18.7 Crushing hospital grade attachment plug and cord connector .125 18.8 Impact hospital grade attachment plug and cord connector .125 18.9 Mechanical drop hospital grade attachment plug

32、 and cord connector 125 19 Tests for Cord Restraint Devices Temperature Test 127 MARKING 20 General 128 21 Extension Cord Sets .129 21.1 General 129 21.2 Polarization .131 21.3 Warning tag 131 21.4 Indoor-use extension cord sets .133 22 Outdoor-Use Extension Cord Sets .135 23 Adapter Cord Sets .136

33、24 Cord Restraint Devices .137 25 Recreational Vehicle and Mobile Home Applications .137 26 Power-Supply Cords Shielded .137 27 Hospital Grade Attachment Plugs, Connectors and Hospital Grade Extension Cords .137 28 Range and Dryer Power-Supply Cord Kits 138 29 Power-Supply Cords for Replacement Use

34、.139 30 Special-Use Power Supply Cords 140 31 Special Use Cord Sets .140 32 Special Use Cord Sets Intended for Replacement Use .141 SUPPLEMENT SA - SEASONAL-USE CORD SETS INTRODUCTION SA1 Scope SA1 CONSTRUCTION SA2 General SA1 SA3 Flexible Cord SA1 SA4 Fittings .SA2 MARCH 11, 2015 CORD SETS AND POWE

35、R-SUPPLY CORDS - UL 817 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SA5 Fittings Intended to Accommodate Fuses or Other Overcurrent Protective Devices SA3 SA6 Overcurrent Protection .SA3 PERFORMANCE SA7 General SA3 SA8 Tests on Female D

36、evices .SA5 SA9 Conductor Secureness Test .SA5 SA10 Strain Relief Test .SA5 SA11 Crushing Test SA5 SA11.1 General .SA5 SA11.2 Molded-on ttings SA6 SA11.3 All other ttings SA6 SA12 Overcurrent Protective Devices .SA6 RATING SA13 General .SA6 MARKING SA14 General .SA7 PACKAGING AND USE INSTRUCTIONS SA

37、15 General .SA9 SUPPLEMENT SB - MARINE SHORE POWER CABLE SETS INTRODUCTION SB1 Scope SB1 SB2 Denitions SB1 SB3 General SB1 CONSTRUCTION SB4 General SB1 SB5 Corrosion Resistance SB2 SB6 Flexible Cord SB2 SB7 Fittings .SB2 PERFORMANCE SB8 Salt Spray Test .SB5 SB9 Mechanical Strength Test .SB5 SB10 Fle

38、xure and Water Spray Test .SB7 SB11 Insulation Resistance Test .SB12 SB12 Dielectric Voltage-Withstand Test SB12 SB13 Exposure to Low Temperature Test SB12 MARCH 11, 2015 CORD SETS AND POWER-SUPPLY CORDS - UL 817 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOU

39、T PERMISSION FROM UL SB14 Exposure to High Temperature Test SB13 SB15 Ozone Resistance Test SB13 SB16 Exposure to Ultraviolet and Water Test SB13 SB17 Accelerated Air Oven Aging Test SB14 INSTRUCTIONS SB18 Instruction Manual .SB14 SUPPLEMENT SC - MANUFACTURING AND PRODUCTION TESTS SC1 Dielectric Vol

40、tage-Withstand Test SC1 SC2 Polarization and Continuity Test .SC2 SUPPLEMENT SD - ROTATING PLUGS INTRODUCTION SD1 Scope SD1 CONSTRUCTION SD2 General SD1 SD3 Insulating Materials SD1 SD4 Flammability SD1 SD5 Electrical Properties .SD2 SD6 Thermal properties SD3 SD7 Comparative Tracking Index Test .SD

41、3 SD8 Glow Wire Test .SD3 SD9 High-Current Arc Resistance to Ignition Test .SD4 PERFORMANCE SD10 General SD5 SD11 Rotational Endurance Test SD5 SD12 Temperature Test SD6 SD13 Dielectric Voltage-Withstand Test SD6 SD14 Mold Stress Relief Test .SD6 Appendix A Component Standards Reference List Appendi

42、x B Illustrative Denitions JANUARY 5, 2016 CORD SETS AND POWER-SUPPLY CORDS - UL 817 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 This standard species the requirements for cord sets and power-supply cords employ

43、ing molded-on or assembled-on ttings, rated 600 V maximum, and intended for use in non-hazardous locations in accordance with the National Electrical Code, ANSI/NFPA 70. 1.2 This Standard also species the requirements for molded-on general-use attachment plugs and cord connectors. 1.3 This Standard

44、also species the requirements for hospital grade attachment plugs and cord connectors. 1.4 This Standard also species the requirements for cord restraint devices. 1.5 These requirements do not cover cord sets intended for temporary outdoor use not to exceed 90 days with outdoor equipment, Christmas-

45、tree, and other seasonal decorative-lighting outts. Such devices are covered by the Standard for Outdoor Seasonal-Use Cord-Connected Wiring Devices, UL 2438. 1.6 These requirements cover devices with remote control features that comply with the Standard for Solid-State Controls for Appliances, UL 24

46、4A. See also 9.9. Devices Employing Remote Control Features. Compliance with the Standard for Automatic Electrical Controls for Household and Similar Use, Part 1: General Requirements, UL 60730-1, and/or the applicable Part 2 standard from the UL 60730 series fullls these requirements. 2 Components

47、2.1 Except as indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard. 2.2 A component is not required to comply with

48、a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established for the intended

49、 conditions of use. 2.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. MARCH 11, 2015 CORD SETS AND POWER-SUPPLY CORDS - UL 817 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 3

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1