UL 921 CRD-2017 UL Standard for Safety Commercial Dishwashers - Section Paragraph Reference Supplement SA Subject Commercial Dishwashers provided with a Heat Pump (Edition 7 March .pdf

上传人:proposalcash356 文档编号:1069056 上传时间:2019-04-02 格式:PDF 页数:2 大小:30.06KB
下载 相关 举报
UL 921 CRD-2017 UL Standard for Safety Commercial Dishwashers - Section Paragraph Reference Supplement SA Subject Commercial Dishwashers provided with a Heat Pump (Edition 7 March .pdf_第1页
第1页 / 共2页
UL 921 CRD-2017 UL Standard for Safety Commercial Dishwashers - Section Paragraph Reference Supplement SA Subject Commercial Dishwashers provided with a Heat Pump (Edition 7 March .pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): DMGR/DMGR7Standard Number: UL 921Standard Title: Standard for Commercial DishwashersEdition Date: March 23, 2016Edition Number: 7Section / Paragraph Reference: Supplement SASubject: Commercial Dishwas

3、hers provided with a Heat PumpDECISION:SUPPLEMENT SA - COMMERCIAL DISHWASHERS SELF-CONTAINED CONDENSING SYSTEMSINTRODUCTIONSA1 ScopeSA1.1 These requirements cover commercial, freestanding dishwashers which incorporate aself-contained condensing system to capture heat and water vapors, thereby reduci

4、ng the residual heatgain to the premises. These dishwashers are sometimes referred to as “ventless dishwashers”. Theserequirements also cover dishwashers provided with a heat pump. These requirements add to theapplicable requirements in the body of this Standard.SA3A Commercial Dishwashers provided

5、with a heat pumpSA3A.1 A dishwasher provided with a heat pump shall comply with the applicable requirements of CSAC22.2 No. 236 and UL 1995, utilizing the additional guidance as specified below:a) The testing shall be conducted as specified in Table SA3;b) Flammable refrigerants shall not be employe

6、d for commercial dishwashers;c) Refrigerant motor compressors shall comply with:1) CSA C22.2 No. 140.2 or CAN/CSA-C22.2 No. 60335-2-34; and2) UL 984 or UL 60335-2-34.d) Refrigerant containing parts shall comply with Clause 34 of UL 1995/CSA C22.2 No. 236;e) Refrigerant marking and amount shall compl

7、y with Clause 44.3(j) of UL 1995/CSA C22.2 No.236; andf) The Manufacturing and Production tests pressure tests for leakage and strength, shall beconducted in accordance with Clause 85 of UL 1995/CSA C22.2 No.236.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT P

8、ERMISSION FROM ULTable SA3 - Test conditions for heat pump commercial dishwasher(See Clause SA3)CSA C22.2 No. 236 / UL 1995 Test Test ConditionsInput Test Conducted in conjunction with UL921/CSA C22.2 No. 168,Clause 7.21Starting Test Conducted in conjunction with UL921/CSA C22.2 No. 168,Clause 7.31H

9、eating Operating Test - Temperature and Pressure, Clause51Conducted in conjunction with the UL 921/C22.2 No. 168Normal Temperature Test, Clause 7.41Indoor Fan Motor Failure and Water Failure Test, Clause 52 Conducted per CSA C22.2 No. 236/UL 1995, for thecondenser fan motor or any water supply circu

10、it needed for theheat pump.Overflow Test Covered by requirement in Clause 7.10 of UL 921/CSA C22.2No. 168Limited Short Circuit Test Covered by requirement in Clause 7.14 of UL 921/CSA C22.2No. 168Strength Test, Clause 70 Conducted per CSA C22.2 No. 236/UL 1995Condensate Drain Blockage Test, Clause 6

11、2 Conducted per CSA C22.2 No. 236/UL 19951The test voltage, room ambient temperature, pressure measurement and, if applicable, condenser/evaporator water supplytemperature and pressure shall be as specified in CSA C22.2 No. 236/UL 1995, or worst-case as supplied in the dishwasherheat-pump.RATIONALE

12、FOR DECISION:This Certification Requirement Decision is intended to document the requirements for commercialdishwashers provided with a heat pump. These types of dishwashers are typically provided with aself-contained condensing system so that a venting system is not needed at the installation. Thes

13、emachines are sometimes designated “ventless dishwashers”. The heat pump is intended to collectoperating exhaust energy and water vapor, and convert them into usable energy for heating the wash andrinse water for the dishwasher.Copyright 2017 UL LLCUL LLC, in performing its functions in accordance w

14、ith its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the standard. They do no

15、t represent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL LLC shall not be responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyobligation or liability for damages, inclu

16、ding consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 921 -2-