IEC 60601-2-45-2011 Medical electrical equipment - Part 2-45 Particular requirements for the basic safety and essential performance of mammographic X-ray equipm.pdf

上传人:diecharacter305 文档编号:1241304 上传时间:2019-08-25 格式:PDF 页数:108 大小:1.51MB
下载 相关 举报
IEC 60601-2-45-2011 Medical electrical equipment - Part 2-45 Particular requirements for the basic safety and essential performance of mammographic X-ray equipm.pdf_第1页
第1页 / 共108页
IEC 60601-2-45-2011 Medical electrical equipment - Part 2-45 Particular requirements for the basic safety and essential performance of mammographic X-ray equipm.pdf_第2页
第2页 / 共108页
IEC 60601-2-45-2011 Medical electrical equipment - Part 2-45 Particular requirements for the basic safety and essential performance of mammographic X-ray equipm.pdf_第3页
第3页 / 共108页
IEC 60601-2-45-2011 Medical electrical equipment - Part 2-45 Particular requirements for the basic safety and essential performance of mammographic X-ray equipm.pdf_第4页
第4页 / 共108页
IEC 60601-2-45-2011 Medical electrical equipment - Part 2-45 Particular requirements for the basic safety and essential performance of mammographic X-ray equipm.pdf_第5页
第5页 / 共108页
点击查看更多>>
资源描述

1、 IEC 60601-2-45 Edition 3.0 2011-02 INTERNATIONAL STANDARD NORME INTERNATIONALE Medical electrical equipment Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices Appareils lectromdicaux Partie 2-45: Ex

2、igences particulires pour la scurit de base et les performances essentielles des appareils de mammographie rayonnement X et des appareils mammographiques strotaxiques IEC60601-2-45:2011 THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2011 IEC, Geneva, Switzerland All rights reserved. Unless otherw

3、ise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any quest

4、ions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. Droits de reproduction rservs. Sauf indication contraire, aucune partie de cette publication ne peu

5、t tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de la CEI ou du Comit national de la CEI du pays du demandeur. Si vous avez des questions sur le copyright de la CEI ou si vous dsirez

6、obtenir des droits supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence. IEC Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About the IEC The International Electrote

7、chnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that yo

8、u have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withd

9、rawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available on-line and also by email. Electropedia: www.electropedia.org The worlds leading online dictio

10、nary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv If you wish to giv

11、e us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la premire organisation mondiale qui

12、 labore et publie des normes internationales pour tout ce qui a trait llectricit, llectronique et aux technologies apparentes. A propos des publications CEI Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possdez ldition la plus rcente, un corrige

13、ndum ou amendement peut avoir t publi. Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm Le Catalogue en-ligne de la CEI vous permet deffectuer des recherches en utilisant diffrents critres (numro de rfrence, texte, comit dtudes,). Il donne aussi des informations sur les proje

14、ts et les publications retires ou remplaces. Just Published CEI: www.iec.ch/online_news/justpub Restez inform sur les nouvelles publications de la CEI. Just Published dtaille deux fois par mois les nouvelles publications parues. Disponible en-ligne et aussi par email. Electropedia: www.electropedia.

15、org Le premier dictionnaire en ligne au monde de termes lectroniques et lectriques. Il contient plus de 20 000 termes et dfinitions en anglais et en franais, ainsi que les termes quivalents dans les langues additionnelles. Egalement appel Vocabulaire Electrotechnique International en ligne. Service

16、Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm Si vous dsirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du Service clients ou contactez-nous: Email: csciec.ch Tl.: +41 22 919 02 11 Fax: +41 22 919 03 00 IEC 60601-2-45 Edition 3.0 201

17、1-02 INTERNATIONAL STANDARD NORME INTERNATIONALE Medical electrical equipment Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices Appareils lectromdicaux Partie 2-45: Exigences particulires pour la sc

18、urit de base et les performances essentielles des appareils de mammographie rayonnement X et des appareils mammographiques strotaxiques INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE XA ICS 11.040.50 PRICE CODE CODE PRIX ISBN 978-2-88912-347-6 Registered tradema

19、rk of the International Electrotechnical Commission Marque dpose de la Commission Electrotechnique Internationale 2 60601-2-45 IEC:2011 CONTENTS FOREWORD . 3 INTRODUCTION . 6 201.1 Scope, object and related standards . 7 201.2 Normative references 9 201.3 Terms and definitions 10 201.4 General requi

20、rements . 11 201.5 General requirements for testing of ME EQUIPMENT 12 201.6 Classification of ME EQUIPMENT and ME SYSTEMS 12 201.7 ME EQUIPMENT identification, marking and documents . 12 201.8 Protection against electrical HAZARDS from ME EQUIPMENT . 16 201.9 Protection against MECHANICAL HAZARDS o

21、f ME EQUIPMENT and ME SYSTEMS . 19 201.10 Protection against unwanted and excessive radiation HAZARDS . 21 201.11 Protection against excessive temperatures and other HAZARDS . 22 201.12 Accuracy of controls and instruments and protection against hazardous outputs . 22 201.13 Hazardous situations and

22、 fault conditions . 22 201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS) . 22 201.15 Construction of ME EQUIPMENT . 22 201.16 ME SYSTEMS 22 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS . 23 202 Electromagnetic compatibility Requirements and tests . 23 203 Radiation protect

23、ion in diagnostic X-ray equipment . 23 Annex AA (informative) Particular guidance and rationale 46 Bibliography 48 Index of defined terms used in this particular standard 49 Table 201.101 Distributed ESSENTIAL PERFORMANCE requirements 11 Table 203.101 Minimum values of TOTAL FILTRATION and factors f

24、or determining the minimum AIR KERMA RATE 38 60601-2-45 IEC:2011 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ MEDICAL ELECTRICAL EQUIPMENT Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices FOREWORD

25、 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electri

26、cal and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to techni

27、cal committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organiz

28、ation for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical c

29、ommittee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publication

30、s is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national a

31、nd regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services

32、and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants

33、or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, u

34、se of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that

35、 some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International standard IEC 60601-2-45 has been prepared by subcommittee 62B: Diagnostic imaging equipment, of IEC technical committee 62

36、: Electrical equipment in medical practice. This third edition cancels and replaces the second edition published in 2001. This edition constitutes a technical revision. The document has been aligned to the 3rdedition of IEC 60601-1 (2005) and to IEC 60601-1-3 (2010). Further modifications have been

37、made with respect to the current technology of MAMMOGRAPHIC X-RAY EQUIPMENT. 4 60601-2-45 IEC:2011 The text of this particular standard is based on the following documents: FDIS Report on voting 62B/817/FDIS 62B/821/RVD Full information on the voting for the approval of this particular standard can

38、be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. In this standard, the following print types are used: Requirements and definitions: roman type. Test specifications: italic type. Informative material a

39、ppearing outside of tables, such as notes, examples and references: in smaller type. Normative text of tables is also in a smaller type. TERMS DEFINED IN CLAUSE 3 OF THE GENERAL STANDARD, IN THIS PARTICULAR STANDARD OR AS NOTED: SMALL CAPITALS. In referring to the structure of this standard, the ter

40、m “clause” means one of the seventeen numbered divisions within the table of contents, inclusive of all subdivisions (e.g., Clause 7 includes subclauses 7.1, 7.2, etc.); “subclause” means a numbered subdivision of a clause (e.g., 7.1, 7.2 and 7.2.1 are all subclauses of Clause 7). References to clau

41、ses within this standard are preceded by the term “clause” followed by the clause number. References to subclauses within this particular standard are by number only. In this standard, the conjunctive “or” is used as an “inclusive or” , so a statement is true if any combination of the conditions is

42、true. The verbal forms used in this standard conform to usage described in Annex H of the ISO/IEC Directives, Part 2. For the purposes of this standard, the auxiliary verb: “shall” means that compliance with a requirement or a test is mandatory for compliance with this standard; “should” means that

43、compliance with a requirement or a test is recommended but is not mandatory for compliance with this standard; “may” is used to describe a permissible way to achieve compliance with a requirement or test. An asterisk (*) as the first character of a title or at the beginning of a paragraph or table t

44、itle indicates that there is guidance or rationale related to that item in Annex AA. A list of all parts of the IEC 60601 series, published under the general title: Medical electrical equipment, can be found on the IEC website 60601-2-45 IEC:2011 5 The committee has decided that the contents of this

45、 publication will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. 6 60601-2-45 IEC:2011 INTR

46、ODUCTION The third edition of this particular standard has been prepared to provide a complete set of safety requirements for MAMMOGRAPHIC X-RAY EQUIPMENT, based on IEC 60601-1:2005 (3rdedition) and its collaterals. This particular standard addresses the system level of MAMMOGRAPHIC X-RAY EQUIPMENT,

47、 which consists of a combination of an X-RAY GENERATOR, associated equipment and ACCESSORIES. Components functions are addressed as far as necessary. The minimum safety requirements specified in this particular standard are considered to provide for a practical degree of safety in the operation of M

48、AMMOGRAPHIC X-RAY EQUIPMENT. Like the previous edition of this Part 2-45, the present third edition includes requirements on HIGH-VOLTAGE GENERATORS for mammography. 60601-2-45 IEC:2011 7 MEDICAL ELECTRICAL EQUIPMENT Part 2-45: Particular requirements for the basic safety and essential performance o

49、f mammographic X-ray equipment and mammographic stereotactic devices 201.1 Scope, object and related standards Clause 1 of the general standard1)applies, except as follows: 201.1.1 Scope Replacement: This international standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MAMMOGRAPHIC X-RAY EQUIPMENT and MAMMOGRAPHIC STEREOTACTIC DEVICES, hereafter also referred to as ME EQUIPMENT. NOT

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1