1、MIL-H- 2 5 7 54 B (USAF ) AMENDMENT 1 20 OCTOBER 1986 This amendmen MILITARY SPECIFICATION HOOD, WINTER , KNIT, WOOL forms a part of Military Specificat-Jn -H-2 75 - B(USAF 1 dated 12 August 1976, and is approved for use within the Department of Air Force and is available for use by all Departments
2、and Agencies of the Depart- PAGE 1 ment of Defense. Add to bottom of Page 1: - “Beneficial comments (recommendations, additions, deletions) and any perti- nent data which may be of use in improving this document should be addressed to: the Engineering Division, San Antonio ALC/MMEDO, Kelly AFB, TX 7
3、8241 by using the self-addressed Standardization Document Improvement Proposal , (DD Form 1426) appearing at the end of this document or by letter. 1.1, delete in its entirety and substitute the following: “1.1 Scopz. knit wool. 2.1, delete in its entirety and substitute “2.1 Add the following new p
4、aragraph 2.1.1: “2.1.1 Specifications and standards. The following specifications and standards form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specifi
5、cations and Standards (DODISS) and supplement thereto, cited in the solicitation.“ Under SPECIFICATIONS, Federal, add: “PPP-B-601 - Box, Wood, Cleated-Plywood.“ Under SPECIFICATIONS, Federal, delete the following: IL-P-378 Plastic Sheet and Strip, Thin Gage, Polyolefin. PPP-B-56 6 Box, Folding, Pape
6、rboard. PPP-B-665 Boxes, Paperboard, Metal Edged and Components. PPP-B-676 Boxes, Set-up. PPP-T-60 Tape, Packaging, Vaterproof .I This specification covers the requirements for a hood, winter, Government documents.“ AMSC N/A FSC 8415 DISTRIBUTION STATEFIENT A. Approved for public release; distributi
7、on is unlimited. 1 of 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-25754B (1) 84 9799906 0385388 8 9 MIL-H-25 754B( USAF) AMENDbENT 1 PAGE 2 Under STANDARDS, Military, add the following: “MIL-STD-147 Palletized Unit Loads. MIL-STD-7 94 Par
8、ts and Equipment Procedures for Packaging of .II Delete parenthetical source paragraph and substitute the following: “(Copies of specifications, standards, and other Government documents required by contractors in connection with specific acquisition functions should be obtained from the contracting
9、 activity or as directed by the contracting officer. )I 2.2, delete line 1 and 2, and substitute the following: “2.2 Other publications. fication to the extent specified herein. Unless otherwise specified, the issues of the documents which are DOD.adopted shall be those listed in the issue of the DO
10、DISS specified in the solicitation. the issues of documents not listed in the DODISS shall be the issue of the nongovernment documents which is current on the date of the solicitation.“ Add the following industry document and parenthetical source statement: The following documents form a part of thi
11、s speci- Unless otherwise specified, “AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) . ASTM D 3951 Packaging , Commer c ia1 (Application for copies of ASTM publications should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.)“ Add the follo
12、wing new paragraph 2.3. “2.3 ,Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, (except for associated detail specifications, specification sheets or MS Standards) the text of this specification shall take precedence Nothing in th
13、is specification, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained.“ PAGE 7 3.11.1, line 2, delete “Type 1“ ad substitute “Type V.“ 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-257548 (
14、1) 84 7777706 0385387 T MIL-i- 25 7 54B (U SAF PAGE 8 4.1, delete in its entirety and substitute the following: “4.1 Responsibility for inspection. Unless otherwise specified in the con- tract, or purchase order the contractor is responsible for the performance of all inspection requirements as spec
15、ified herein. in the contract, the manufacturer may use his own or any other facilities suitable for the performance of the inspection requirements specified herein with approval by the Government. The Government reserves the right to perform any of the inspections set forth in the specification whe
16、re such inspections are deemed necessary to assure supplies and services conform to prescribed requirements.“ Add the following new paragraph 4.1.1: “4.1.1 Responsibility for compliance. sections 3 and 5. a part of the contractors overall inspection system or quality program. The absence of any insp
17、ection requirements in the specification shall not relieve the contractor of the responsibility of assuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract. known defective material, either indicated or actual, nor does it commit
18、the Government to acceptance of defective material.“ Except as otherwise specified All items must meet all requirements of The inspection set forth in this specification shall become Sampling in quality.conformance does not authorize submission of PAGE 12 5.1, delete and substitute the following: “5
19、.1 Packaging. (see 6.2).“ Packaging shall be Level A, C or Commercial as specified 5.1.1, delete in its entirety and substitute the following: “5.1.1 Level A. sealed bx 5.3.1) that is made of a minimum of .0015-inch thick poly- ethylene. Prior to or during the heat-sealing operation, excess air shal
20、l be expelled from the bag to the extent necessary to permit packaging in the intermediate container.“ Each hood shall be folded in half and placed in a heat- 5.1.1.1, delete in its entirety and substitute the following: “5.1.1.1 Ten hoods of one size only and individually packaged as specified shal
21、l be placed in a box conforming to PPP-B-636, Style RSC, Type CF and SF, class domestic, Variety SW, Grade 275. The inside dimen- sions of the box shall be approximately 9 inches in length, 9 inches in width, and 5 inches in depth. 5,1.2, delete and substitute: “5.1.2 Level C. this level. I Intermed
22、iate packaging. The box shall be secured with-gummed tape.“ Hoods shall be packaged to the MIL-STD-794 requirements for 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-25754B (USAF) Add the following new paragraph 5.1.3: “5.1.3 Commercial. bl
23、e requirements of ASTM D 3951.“ Delete paragraphs 5.2, 5.2.1, 5.2.2, 5.2.3 and substitute the following: “5.2 Packing. Packing shall be Level A, By C or Commercial as specified (see 6.2). Hoods shall be packaged in accordance with the applica- 5.2.1 Level A. Twelve boxes, containing 120 hoods (ten h
24、oods in each box) of the same size and packaged as specified, shall be packed in a box conform- ing to overseas type, Style A, Grade A, Type 1, of PPP-B-601. The inside dimensions of the box shall be approximately 19 inches in length, 19 inches in width, and 15% inches in depth. Each shipping contai
25、ner shall be closed and reinforced in accordance with the appendix of the container specification. Toward the end of the contract or when the quantity of hoods of the same size is less than the quantity required per shipping container, mixed sizes may be packed in the same shipping container. 5.2.2
26、Level B. TIrelve boxes, containing 120 hoods (ten hoods in each box) of the same size and packaged as specified, shall be packed in a box confom- ing to Class 2, compliance symbol V3c or VS, Style RSC of PPP-B-636. inside dimensions of the box shall be approximately 19 inches in length, 19 inches in
27、 width, and i54 inches in depth. be closed and reinforced in accordance with the appendix of the container specification. the hoods of the same size is less than the quantity required per shipping container, mixed sizes may be packed in the same shipping container. 5.2.3 Level C. the MIL-STD-794 req
28、uirements for this level .It . The Each shipping container shall Toward the end of the contract or when the quantity of Hoods, packaged as specified in 5.1, shall be packed to PAGE 13 Add the following new paragraph 5.2.4: “5.2.4 Commercial. in accordance with the applicable requirements of Asml D 3
29、951.“ Hoods, packaged as specified in 5.1, shall be packed 5.3 Line 2, after MIL-STD-129, add “or ASn D-3951.“ Add the following new paragraph 5.4 as follows: “5.4 Palletization. Unitized loads, commensurate with the level of packing specified in the contract or order, shall be palletized in accorda
30、nce with MIL-STD-147. . to the greatest extent possible. If the container is of a size which does not conform to any of the pallet patterns specified in MIL-STD-147, the pallet pattern used shall first be approved by the contracting officer. Palletized loads shall be uniform in size and quantities 6
31、.1, line 2, delete “survival kits.“ 6.2, add the following Subparagraph (e): “(e) h%en palletization is required (see 5.4) .“ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-25 7 54B (USAF) Custodian Air Force - 99 Review Activity: DLA - CT User Activity: Air Force - 45 Preparing Activity Air Force - 82 Project No. 8415-F491 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-