1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C78.1450-1983 (R2002)Electric Lamps - Projection Lamps, Incandescent, Method for Life TestingANSI C78.1450-1983 (R2002) American National Standard Projection Lamps, Incandescent, Method for Life Testing Secretariat: National
2、 Electrical Manufacturers Association Approved as an American National Standards Institute, Inc. NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed
3、. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document contained herein is one, are developed th
4、rough a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of c
5、onsensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or oth
6、er damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or comple
7、teness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue o
8、f this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document
9、should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources,
10、which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety
11、or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. Ol . 6 LO !“ cO “ (.) II) z t ANSI C78.14501983 Revisio
12、n of ANSI C78.14501982 American National Standard for electric lamps incandescent projection lamps method for if e testing Approved July 1, 1983 1. Scope 1.1 This standard describes a method for life testing Incandescent projection lamps. It also defines associ ated terms and describes a method of e
13、valuating accept ability. 1.2 The life test method specified is primarily for use by lamp manufacturers but can be used by any quali fied testing laboratory provided all the test require ments are met. 1.3 This standard ls not intended to cover life testing of lamps in projection equipment, although
14、 it can be used as a guide for such testing. It shall be the responsi bility of the projection equipment manufacturer to en sure that use conditions of the lamp meet respective lamp conditions as specified by the lamp manufacturer. 2. Definitions . 2.1 Lamp Life. The accumulated time in hours that t
15、he filament will light. Failure of the filament to light for any cause other than mechanical shock is considered the end of life. 2.2 Rated Life. A declared value assigned by the lamp manufacturer. 2.3 Average Life, The statisticaf average life of a spe-Secretariat: National Electrical Manufacturers
16、 Association Pago I of 2 pages cific sampling of lamps as determined by means of a life test run in accordance with this standard. 2.4 Early Failures. Lamps that burn five minutes or less. Suclt lamps shall be excluded from the average Ii fe calculation. 2.5 Acceptable Life. Acceptable life is a com
17、puted value based on rated life and sample size. 3. Test Conditions 3.1 Lamp Test Fixture 3.1.1 The lamp test fixture shall have a suitable lampholder for the lamp being tested. 3.1.2 The fixture shall be physically stable and es sentially free of all vibration. 3.1.3 The lamp shall be operated with
18、in the range of burning positions specified by the lamp manufac turer. 3.1.4 Fixtures for testing lamps designed to operate in conjunction with functional devices that affect fila ment life, such as reimaging back mirrors, shall incor porate those devices. 3.1.5 The fixture shall be equipped with a
19、voltage regulator, cooling system, and cycle timer such that the conditions stated in 3.2, 3.3, and 3.4 are met. 3.1.6 A photocell, current-sensing device, or other means shall be used to operate an accumulated time An American National Standard implies a consensus of those substantially concerned w
20、ith its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Stan dard does not in any respect preclude anyone, whether he has approved the standard or not, from manufacturing,
21、marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review and users are cautioned to obtain the latest editions. The American National Standards Institute does not develop standards and will in no cir
22、cumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. CAUTION NOTICE: This American National Standard may be revi
23、sed or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of ap proval. Purchasers of American National Standards may receive current information on all
24、standards by calling or writing the American Na-tional Standards Institute. Copyright 1983 by 3lS1 American National Standards Institute, 140 Broadway, New York, N.V. 10018 ANSI3Cl183/3 Page 2 of 2 pages device for recording the time that a lamp is burning. 3.2 Voltage 3.2.l Unless otherwise specifi
25、ed, lamps shall be operated at rated alternating current voltage 0.5%. Voltage shall be measured with a true rms voltmeter as close to the lamp base terminals as is practical. 3.2.2 Lamps which are designed for special power requirements, such as soft turn-on, direct current, and nonsinusoidal alter
26、nating current shall be tested at the voltage conditions specified for those lamps. 3.3 Lamp Cooling. During normal use, natural heating up and cooling down may have an effect on the life of an individual lamp. Therefore, to simulate normal use, lamp cooling during the ON-OFF duty cycle specified in
27、 3.4 shall be such that: (1) The lamp base and seal temperatures during the ON time of the duty cycle do not exceed the maximum temperatures specified by the lamp manufacturer (2) The bulb temperature during the ON time of the duty cycle does not exceed the maximum tempera ture or fall below the min
28、imum temperature specified by the lamp manufacturer (3) All components of the lamp cool down to or near room temperature during the OFF time of the duty cycle. 3.4 Test Cycle 3.4.1 Lamps having a rated life of200 hours or less shall be tested with a 60-minute or less ON-OFF duty cycle, with 30 minut
29、es as the maximum ON time. 3.4.2 Lamps having a rated life of more than 200 hours shall be tested with a 24-hour or less (but greater than 60 minutes) ON-OFF duty cycle, with 12 hours as the maximum ON time. 3.4.3 The following are examples of ON-OFF duty cycles: Rated Life of Lamp (Hours) (1) 200 o
30、rless (2) More than 200 Examples of Duty Cycles (a) 15 minutes ON-5 minutes OFF (b) 15 minutes ON-15 minutes OFF (c) 30 minutes ON-30 minutes OFF (a) 11 hours ON-1 hour OFF (b) 12 hours ON-12 hours OFF 3.4.4 Lamps designed for special burning cycles, such as continuous burning or very short (flashin
31、g) cycles, shall be tested accordingly. The special burning cycle shall be reported in the test documentation. 4. Test Procedure 4.1 A sample oflamps shall be cycled in lamp fixtures ANSI C78.1450-1983 under the conditions stated In Section 3 until the end oflife as defined in 2.1. 4.2 The average l
32、ife of a given sample of lamps shall be calculated as follows: X=A/B . where: X = average life of a given sample of lamps, in hours A = total accumulated hours of ON time for all the lamps in the sample B =number of lamps in the sample 5. Acceptability 5.1 The lower limit of acceptable life of a giv
33、en sample of lamps shall be calculated as follows: Y=CD where: Y = lower limit of acceptable life of a given sample of lamps, In hours C= rated life of lamps in the sample, in hours D =lowest percentage of rated life, from Table 1 5.2 In order to be acceptable, the average life of a given sample ofl
34、amps shall be not less than the lower limit of acceptable life as calculated in accordance with 5.1. EXAMPLE: A sample consisting of six lamps, each having a rated life of 50 hours, is tested, and the total number of hours of ON time for the six lamps is 222 hours. The average life of this sample= 2
35、22/6 = 37 hours. The lower limit of acceptable life will be 50 X 69% = 34.5 hours. This sample is acceptable because the average life (37 hours) is not less than the lower limit of acceptable life (34.5 hours). Table 1 Sample Size versus Percntage of Rated Life Number of Lamps in Sample 250 and over
36、 249-100 99-55 54-45 44-35 34-30 29-25. 24-20 19-18 17-16 15-14 13-12 11 10 9 8 7 6 5 Lowest Percentage of Rated Life 95 92 90 89 87 86 85 83 82 81 80 78 77 76 75 73 72 69 66 NOTE: Table 1 is taken from Federal Specification W-L-126a Amendment-!, dated August 17, 1961, TABLE III - Life To!eranpe. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1300 NORTH 17TH STREET, SUITE 900 ROSSLYN. VA 22209www.NEMA.orgTO ORDER ADDITIONAL NEMA STANDARDS VISITWWW.GLOBAL.IHS.COM OR CALL 1-800-854-7179/1-303-397-79565612_0514TB