ANSI NEMA C82.2-2002 Lamp Ballasts - Method of Measurement of Fluorescent Lamp Ballasts.pdf

上传人:dealItalian200 文档编号:437624 上传时间:2018-11-14 格式:PDF 页数:20 大小:501.76KB
下载 相关 举报
ANSI NEMA C82.2-2002 Lamp Ballasts - Method of Measurement of Fluorescent Lamp Ballasts.pdf_第1页
第1页 / 共20页
ANSI NEMA C82.2-2002 Lamp Ballasts - Method of Measurement of Fluorescent Lamp Ballasts.pdf_第2页
第2页 / 共20页
ANSI NEMA C82.2-2002 Lamp Ballasts - Method of Measurement of Fluorescent Lamp Ballasts.pdf_第3页
第3页 / 共20页
ANSI NEMA C82.2-2002 Lamp Ballasts - Method of Measurement of Fluorescent Lamp Ballasts.pdf_第4页
第4页 / 共20页
ANSI NEMA C82.2-2002 Lamp Ballasts - Method of Measurement of Fluorescent Lamp Ballasts.pdf_第5页
第5页 / 共20页
亲,该文档总共20页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C82.2-2002 (R2016)Lamp Ballasts Method of Measurement of Fluorescent Lamp BallastsANSI C82.2-2002 (R2007, R2016) Page i 2016 National Electrical Manufacturers Association ANSI C82.2-2002 (R2007, R2016) American National Stan

2、dard for Lamp Ballasts Method of Measurement of Fluorescent Lamp Ballasts Secretariat: National Electrical Manufacturers Association Approved: July 12, 2016 American National Standards Institute, Inc. ANSI C82.2-2002 (R2007, R2016) Page ii 2016 National Electrical Manufacturers Association NOTICE AN

3、D DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating i

4、n the development of this document. ANSI standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest

5、in the topic covered by this publication. While NEMA administers the process to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments c

6、ontained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or relia

7、nce on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA

8、does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or ent

9、ity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given cir

10、cumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance w

11、ith the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health- or safety-related information in this document shall not be attributable to NEMA and is so

12、lely the responsibility of the certifier or maker of the statement. ANSI C82.2-2002 (R2007, R2016) Page i 2016 National Electrical Manufacturers Association AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by The American National Standards Institute, Inc. (

13、ANSI) that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus is established when, in the judgment of the AN

14、SI Board of Standards Review, substantial agreement has been reached by directly, and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effor

15、t be made toward their resolution. The existence of an American National Standard does not in any respect preclude anyone, whether s/he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. It is inte

16、nded as a guide to aid the manufacturer, the consumer, and the general public. The American National Standards Institute, Inc., does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to i

17、ssue an interpretation of an American National Standard in the name of the American National Standards Institute, Inc. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on this title page. CAUTION NOTICE: This American National Standard may be revised

18、or withdrawn at any time. The procedures of the American National Standards Institute, Inc., require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the

19、American National Standards Institute, Inc. Published by National Electrical Manufacturers Association 1300 North 17thStreet, Suite 900 Rosslyn, Virginia 22209 2016 National Electrical Manufacturers Association All rights, including translation into other languages, reserved under the Universal Copy

20、right Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the p

21、ublisher. Printed in the United States of AmericaANSI C82.2-2002 (R2007, R2016) Page ii 2016 National Electrical Manufacturers Association This standard is dedicated to the memory of J. F. Luchetta ANSI C82.2-2002 (R2007, R2016) Page iii 2016 National Electrical Manufacturers Association Foreword (T

22、his foreword is not part of ANSI C82.2)Suggestions for improvement of this standard should be submitted to the Secretariat C82, American National Lighting Group of the National Electrical Manufacturers Association, 1300 North 17th Street, Suite 900, Rosslyn, VA 22209. This standard was processed and

23、 approved by Accredited Standards Committee on Lamp Ballasts, C82. Committee approval of the standard does not necessarily imply that all committee members voted for that approval. ANSI C82.2-2002 (R2007, R2016) Page iv 2016 National Electrical Manufacturers Association ANSI C82.2-2002 (R2007, R2016

24、) Page v 2016 National Electrical Manufacturers Association CONTENTS Foreword iii 1 Scope 1 2 Normative References 1 3 Pertinent measurements . 1 4 Electrical Supply CharacteristicsTest Ballast Measurement Circuits 2 5 Electrical Supply CharacteristicsReference Ballast Measurement Circuits. . 3 6 Am

25、bient Conditions For Lamp Measurements . 3 7 Test Measurement Circuits . 3 8 Electrical Instruments . 5 9 Open Circuit Voltage . 5 10 Starting Current for Instant Start and Rapid Start Ballasts . . 6 11 Input Power Factor. . 6 12 Ballast Factor 7 13 Ballast Efficiency Factor (BEF) . 7 14 Ballast Reg

26、ulation . 8 15 Current Measurements 8 16 Cathode HeatingVoltage Requirements . 9 17 Cathode HeatingReheat Current Requirements 9 18 Starter Terminal Voltage 10 19 Starting Capacitor 10 Figures Figure 1 Input Characteristics Measurement Circuit .4 Figure 2 Lamp Characteristics Measurement Circuit . 4

27、 Figure 3 Measurement of Peak and RMS Lamp Current for Rapid Start Lamps . 8 ANSI C82.2-2002 (R2007, R2016) Page vi 2016 National Electrical Manufacturers Association ANSI C82.2-2002 (R2007, R2016) Page 1 2016 National Electrical Manufacturers Association 1 Scope This standard outlines the procedure

28、s to be followed and the precautions to be observed in measuring and testing line frequency fluorescent lamp ballasts as specified in C82.1 with either hot-cathode or cold-cathode fluorescent lamps. 2 Normative References This standard is intended for use in conjunction with the following American N

29、ational Standards. When the American National Standards referred to in this document are superseded by a revision approved by the American National Standards Institute, Inc. the revision shall apply. ANSI/NFPA No. 70-1993 National Electrical Code ANSI C78.1-1991 (R1996) American National Standards f

30、or Dimensional and Electrical ANSI C78.2-1991 (R1996) Characteristics of Fluorescent Lamps ANSI C78.3-1991 (R1996) ANSI C78.4-1992 (R1997) ANSI C78.375-1997 American National Standard for Fluorescent LampsGuide for Electrical Measurements ANSI C82.1-1997 American National Standard for Lamp BallastLi

31、ne Frequency Fluorescent Lamp Ballasts ANSI C82.3-1983 (R1998) American National Standard Specification for Fluorescent LampReference Ballasts Code of Federal Regulations 10CFR430 Energy Conservation Program for Consumer Products ANSI/UL 935-1992 Standard for Fluorescent Lamp Ballasts Underwriters L

32、aboratories Inc. 3 Pertinent Measurements The measurements in 3.1 and 3.2 are required to determine the compliance of ballast and ballast-lamp combinations with the specification of ANSI C82.1. Additional limitations as related to specific test conditions are listed in the appropriate lamp data shee

33、ts. 3.1 Ballast Output Circuit Measurements 3.1.1 Lamp Starting Conditions a) RMS open-circuit voltage b) Peak open-circuit voltage c) Lamp voltage waveshape-crest factor d) Maximum-peak (open-circuit) voltage from starting aid to any cathode on each lamp circuit (rapid start ballast) e) Capacitance

34、 of starting capacitor(s) (rapid start ballast) f) RMS voltage to cathode dummy-load (rapid start ballast) g) RMS current through dummy-load resistor (instant start ballast and some rapid start ballasts) h) RMS preheat current (preheat start ballasts) ANSI C82.2-2002 (R2007, R2016) Page 2 2016 Natio

35、nal Electrical Manufacturers Association 3.1.2 Lamp Operating Conditions a) RMS voltage b) RMS current c) Peak current d) Power (switch start and instant start ballasts) e) Relative light output (rapid start ballast) f) Cathode heating voltage (rapid start ballast) g) Lamp current wave shape-crest f

36、actor 3.2 Ballast Input Circuit Measurements 3.2.1 Operating Conditions a) RMS voltage b) RMS current c) Power factor d) Ballast efficiency factor 4 Electrical Supply CharacteristicsTest Ballast Measurement Circuits 4.1 Test voltage and frequency For test purposes, ballasts shall be operated at eith

37、er their rated line voltage or for certain types of tests at other voltages as specified in ANSI C82.1. In addition, specific test input voltages as related to tests conducted on ballast-lamp combinations can be found in the appropriate lamp data sheets. Where ballasts are labeled for a range of pri

38、mary voltages, testing should be conducted on the lowest and highest USA design center voltage for the given ballast. Ballasts shall always be operated at their rated frequency. 4.2 Line Voltage Wave Shape Throughout the full range of test requirements the AC voltage supply at the input terminals to

39、 the ballast-lamp combination shall have a wave shape such that the RMS summation of the harmonic components does not exceed 3% of the fundamental. 4.3 Stability of Supply Voltage The line voltage shall be as steady and free from sudden changes as possible. For best results the voltage should be reg

40、ulated to within 0.1%. If adequate automatic regulation is not available, constant checking and readjustments are essential for obtaining accurate measurements.14.4 Supply-Source Impedance The supply source shall have sufficient power capacity and sufficiently low impedance, compared with the ballas

41、t impedance, to ensure that the voltage to the ballast or lamp-ballast combination does not vary by more than 3% with the lamp-ballast combination in and out of the circuit. 1 If the static type voltage stabilizer is used, it is particularly important to check the wave shape to see that it meets the

42、 specification given in 4.2. This should be checked both with and without load. ANSI C82.2-2002 (R2007, R2016) Page 3 2016 National Electrical Manufacturers Association 5 Electrical Supply CharacteristicsReference Ballast Measurement Circuits The general characteristics of reference ballasts are des

43、cribed in ANSI C82.3 and ANSI C78.375. The specific values of impedance, reference current, and rated input voltage for the reference ballasts corresponding to each lamp type are given in the appropriate lamp data sheets. The reference ballast while operating fluorescent lamps shall meet all electri

44、cal supply characteristics cited in ANSI C82.3 and ANSI C78.375. 6 Ambient Conditions for Lamp Measurements Variations in ambient temperature, air movement along the bulb wall surface, and lamp burning positions can affect the electrical characteristics as well as the output of a reference lamp. The

45、 ambient conditions for lamp measurements cited in ANSI C78.375 shall be followed when testing line frequency ballasts on reference lamps. Unless otherwise specified, the ambient temperature for all tests is 25OC 1OC. 7 Test Measurement Circuits 7.1 Circuit Grounding In all of the wiring diagrams sh

46、own in the standard, the side containing the instruments current coil is shown connected to the grounded supply conductor. This is a recommended safety precaution, since many types of portable instruments have current coil terminals that are not insulated and that can constitute a shock hazard if no

47、t kept at ground potential. In those situations where the available power source is grounded at some other potential (for example, a 120/240, three-wire supply with a midpoint ground), the grounded connection as shown in these diagrams shall not be used, but in such cases other arrangements shall th

48、en be made to minimize the shock hazard. ANSI C82.2-2002 (R2007, R2016) Page 4 2016 National Electrical Manufacturers Association 7.2 Basic Instrument Circuit The recommended methods of connecting the instruments to the lamp and ballast circuit are provided in and Figure 2. If individual instruments

49、 are used then only one instrument at a time shall be connected in the measurement circuits. TO A A From test ballast lamp leads S V TO B B A W Power Analyzer Figure 1 Input Characteristics Measurement Circuit NOTE: Current terminals of instruments are shown as o Potential terminals of instruments are shown as o Supply Voltage A To test ballast V input terminalsA W Power Analyzer Figure 2 Lamp Characteristics Measurement Circuit NOTE

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1