ANSI NEMA C82.5-2016 Lamp Ballasts - High-Intensity Discharge and Low-Pressure Sodium Lamps.pdf

上传人:dealItalian200 文档编号:437627 上传时间:2018-11-14 格式:PDF 页数:19 大小:321.01KB
下载 相关 举报
ANSI NEMA C82.5-2016 Lamp Ballasts - High-Intensity Discharge and Low-Pressure Sodium Lamps.pdf_第1页
第1页 / 共19页
ANSI NEMA C82.5-2016 Lamp Ballasts - High-Intensity Discharge and Low-Pressure Sodium Lamps.pdf_第2页
第2页 / 共19页
ANSI NEMA C82.5-2016 Lamp Ballasts - High-Intensity Discharge and Low-Pressure Sodium Lamps.pdf_第3页
第3页 / 共19页
ANSI NEMA C82.5-2016 Lamp Ballasts - High-Intensity Discharge and Low-Pressure Sodium Lamps.pdf_第4页
第4页 / 共19页
ANSI NEMA C82.5-2016 Lamp Ballasts - High-Intensity Discharge and Low-Pressure Sodium Lamps.pdf_第5页
第5页 / 共19页
亲,该文档总共19页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C82.5-2016Lamp Ballasts High-Intensity Discharge and Low-Pressure Sodium LampsANSI C82.5-2016 Page 1 2016 National Electrical Manufacturers Association ANSI C82.5-2016 American National Standard for Lamp Ballasts High-Intens

2、ity Discharge and Low-Pressure Sodium Lamps Secretariat: National Electrical Manufacturers Association Approved: August 23, 2016 American National Standards Institute, Inc. 2016 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered tec

3、hnically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. ANSI standards and guideline pu

4、blications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers th

5、e process to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaim

6、s liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warra

7、nty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual m

8、anufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person

9、 or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by

10、 this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or

11、inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health- or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement.

12、 ANSI C82.5-2016 Page i AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by The American National Standards Institute, Inc. (ANSI) that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. An

13、American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly, and materially affected interests. Substantial agre

14、ement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The existence of an American National Standard does not in any respect preclude anyone, whether s/

15、he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. It is intended as a guide to aid the manufacturer, the consumer, and the general public. The American National Standards Institute, Inc., does

16、not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute, Inc. Requests for i

17、nterpretations should be addressed to the secretariat or sponsor whose name appears on this title page. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute, Inc., require that action be taken periodicall

18、y to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute, Inc. Published by National Electrical Manufacturers Association 1300 North 17thStreet, Suite 9

19、00 Rosslyn, Virginia 22209 2016 National Electrical Manufacturers Association All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copy

20、right conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Printed in the United States of America ANSI C82.5-2016 Page ii 2016 National Electrical Manufacturers Association CONTENTS

21、 1 Scope . 1 2 Normative References 1 3 Definitions 1 4 Types of Reference Ballasts . 1 5 Ballast Marking 2 6 Design Characteristics . 2 7 Operating Characteristics 3 8 Methods of Measurement and Calibration . 4 ANNEXES Annex A 8 Annex B Measurement and adjustment of the impedance and power-factor c

22、haracteristics of a reference ballastguide for use of the preferred method 9 Annex C Measurement and adjustment of the impedance and power-factor characteristics of a reference ballastdescription of and guide for an alternate method 11 FIGURES Figure 1 Circuit for Impedance Measurement 7 Figure 2 Ci

23、rcuit for Power-Factor Measurement 7 Figure C1 Circuit for impedance and power-factor measurement 11 ANSI C82.5-2016 Page 1 2016 National Electrical Manufacturers Association 1 Scope This standard describes the essential features and operating characteristics of reference ballasts for high-intensity

24、 discharge and low-pressure sodium lamps operating on 60 Hz sinusoidal ballast systems. The items specified are those necessary to ensure accurate and reproducible results when lamps or ballasts are being tested. The specific values of rated input voltage and impedance for each lamp type are listed

25、in the appropriate American National Standards for high-intensity discharge and low-pressure sodium lamps. 1.1 Important Patent Disclaimer At the time of publication, it is possible that some elements of this document may be the subject of patent rights. When this standard was approved for publicati

26、on, the National Electrical Manufacturers Association (NEMA) did not know of any patent applications, patents pending, or existing patents. NEMA shall not be held responsible for identifying any or all such patent rights. 2 Normative References The following standards contain provisions that, throug

27、h reference in this text, constitute provisions of this American National Standard. All standards are subject to revision, and parties to agreements based on this American National Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated

28、below. ANSI C78.40-2016 American National Standard for Electric LampsSpecifications for Mercury Lamps ANSI C78.41-2006 American National Standard for Electric LampsGuidelines for Low-Pressure (LPS) Sodium Lamps ANSI C78.42-2009 (R2016), American National Standard for Electric LampsHigh-Pressure Sodi

29、um (HPS) Lamps ANSI C78.43-2013 American National Standard for Electric LampsSingle-Ended Metal Halide Lamps ANSI C78.44-2016, American National Standard for Electric LampsDouble-Ended Metal Halide Lamps ANSI C82.6-2015, American National Standard for Lamp BallastsBallasts for High-Intensity Dischar

30、ge (HID) LampsMethods of Measurement ANSI C82.9-2016, American National Standard for Lamp BallastsHigh-Intensity Discharge (HID) and Low-Pressure Sodium (LPS) LampsDefinitions 3 Definitions Definitions of terms that apply specifically to the subject treated in this standard are provided in ANSI C82.

31、9. 4 Types of Reference Ballasts There are two types of reference ballasts. The fixed-impedance type is adjusted and calibrated at the time of manufacture and is permanently set at a particular value of impedance. It can be used for only the type of lamp for which it was calibrated. The variable-imp

32、edance type of reference ballast consists of an adjustable reactor, usually of the moving core type, and a separate variable resistor connected in series. ANSI C82.5-2016 Page 2 2016 National Electrical Manufacturers Association 5 Ballast Marking 5.1 Marking A reference ballast shall be provided wit

33、h a durable nameplate securely attached to a permanent structure of the ballast. The information shown in clauses 5.1.1 or 5.1.2 shall be legibly etched or stamped on it. 5.1.1 Fixed-Impedance Type Information on the nameplate shall include the following: a. Lamp type, watts, and current b. Supply v

34、oltage and frequency c. Impedance d. Manufacturers catalog or model number e. Manufacturers serial number f. Manufacturers name 5.1.2 Variable-Impedance Type Information on the nameplate shall include the following: a. Impedance range at the rated frequency(ies) b. Maximum voltage per coil and maxim

35、um voltage across reactor c. Maximum current per coil d. Manufacturers catalog or model number e. Manufacturers serial number f. Manufacturers name g. Frequency(ies) h. Connection diagram 5.2 Magnetic Shielding If a reference ballast is magnetically shielded, this information shall be indicated on t

36、he nameplate described in clause 5.1. 6 Design Characteristics 6.1 General Design A reference ballast is an inductive reactor, with or without an additional series resistor, designed to provide the operating characteristics listed in clause 7. 6.2 Permanence of Impedance 6.2.1 Fixed ImpedanceType Ba

37、llasts Since the fixed-impedance type of reference ballast is intended to serve as a permanent baseline of reference, it is vitally important that the ballast be so constructed as to provide permanence of impedance under normal conditions of use and abuse. A check of the impedance of the ballast sha

38、ll give values repeatable to within 0.1% of those previously determined. ANSI C82.5-2016 Page 3 2016 National Electrical Manufacturers Association 6.2.2 Variable impedancetype ballasts The variable-impedance type of reference ballast, when adjusted to any given value of impedance shall be capable of

39、 holding that adjustment through normal periods of use. For this purpose, suitable means shall be provided for mechanically locking the movable core (or other movable parts) in any desired position. 6.3 Enclosure This clause intentionally left blank. 6.4 Magnetic shielding A reference ballast, to be

40、 considered magnetically shielded, shall be so designed and constructed that its impedance at reference current shall not be changed by more than 0.2% when a -inch-thick plate of magnetic steel is placed within one inch of any face of the ballast enclosure. The steel plate shall have dimensions at l

41、east two inches greater than the maximum dimension of the ballast enclosure and shall be placed in geometric symmetry to each surface as tested. In the event that a reference ballast is not magnetically shielded, precautions shall be taken to keep magnetic objects far enough from the leakage field t

42、hat the impedance of the ballast will not be altered by more than the 0.2% mentioned above. Table 1 Ballast Power Factors Lamp type Wattage Power factor 0.005 High-pressure sodium Metal halide Mercury Low-pressure sodium Low-pressure sodium All All All Less than 18 W 18 W and above 0.075 0.075 0.075

43、 0.075 0.060 Note: Wattage loss includes losses due to leads. 6.5 Inclusion of Instrument current coil Impedance When a variable-impedance type of reference ballast is being used, a choice may be made as to whether the impedance of the instrument current coils (the ammeter and wattmeter) will or wil

44、l not be included as part of the impedance of the reference ballast. Either choice is satisfactory, but the other aspects of the calibrating procedure and the subsequent use of the ballast shall be compatible with the particular procedure being followed. For the sake of simplicity, the procedures de

45、scribed in this standard are those applicable when the impedance of the current coils is not included in the impedance of the reference ballast. Annex A, however, covers the changes in procedures and circuitry that would be required if the current coils were included. 7 Operating characteristics 7.1

46、 General The specifications in this section apply to measurements made at the rated frequency of the ANSI C82.5-2016 Page 4 2016 National Electrical Manufacturers Association reference ballast and with the ballast parts and windings conditioned at an ambient temperature of 25C 5C. 7.2 Rated input vo

47、ltage The rated input voltage of a reference ballast shall be in accordance with the value specified in the applicable standards from ANSI C78.40, ANSI C78.41, ANSI C78.42, ANSI C78.43, or ANSI C78.44. 7.3 Impedance The impedance of a reference ballast shall be within 0.5% of the value specified in

48、the applicable standard from ANSI C78.40, ANSI C78.41, ANSI C78.42, ANSI C78.43, or ANSI C78.44. 7.4 Linearity For any value of the current from 50%115% of the reference current, the impedance of the reference ballast shall be within 4.0% of the value specified in the applicable standard from ANSI C

49、78.40, ANSI C78.41, ANSI C78.42, ANSI C78.43, or ANSI C78.44. 7.5 Ballast Power Factor The power factor of the reference ballast (ratio of ballast wattage loss to ballast volt-amperes) when the ballast is carrying reference current shall be as specified in Table 1. The wattage loss will include losses due to lead resistance. In case of conflict between Table 1 and ANSI C78.40, ANSI C78.41, ANSI C78.42, ANSI C78.43, or ANSI C78.44, the value in the appropriate lamp standard shall be used. 7.6 Te

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1