1、 TIA-4966 May 2014Telecommunications Infrastructure Standard for Educational Facilities ANSI/TIA-4966-2014 APPROVED: MAY 12, 2014 NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, fa
2、cilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Standards and Publications shall not in any respect preclude any member or non-member of TIA from m
3、anufacturing or selling products not conforming to such Standards and Publications. Neither shall the existence of such Standards and Publications preclude their voluntary use by Non-TIA members, either domestically or internationally. Standards and Publications are adopted by TIA in accordance with
4、 the American National Standards Institute (ANSI) patent policy. By such action, TIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This Standard does not purport to address all safety problems associated
5、 with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. Any use of trademarks in this document are for information
6、purposes and do not constitute an endorsement by TIA or this committee of the products or services of the company. (From Project No. ANSI/TIA-PN-4966-D1, formulated under the cognizance of the TIA TR-42 Telecommunications Cabling Systems, TR-42.1 Subcommittee on Commercial Building Telecommunication
7、s Cabling(568, 942, 862, 1179). Published by TELECOMMUNICATIONS INDUSTRY ASSOCIATION Technology (b) there is no assurance that the Document will be approved by any Committee of TIA or any other body in its present or any other form; (c) the Document may be amended, modified or changed in the standar
8、ds development or any editing process. The use or practice of contents of this Document may involve the use of intellectual property rights (“IPR”), including pending or issued patents, or copyrights, owned by one or more parties. TIA makes no search or investigation for IPR. When IPR consisting of
9、patents and published pending patent applications are claimed and called to TIAs attention, a statement from the holder thereof is requested, all in accordance with the Manual. TIA takes no position with reference to, and disclaims any obligation to investigate or inquire into, the scope or validity
10、 of any claims of IPR. TIA will neither be a party to discussions of any licensing terms or conditions, which are instead left to the parties involved, nor will TIA opine or judge whether proposed licensing terms or conditions are reasonable or non-discriminatory. TIA does not warrant or represent t
11、hat procedures or practices suggested or provided in the Manual have been complied with as respects the Document or its contents. If the Document contains one or more Normative References to a document published by another organization (“other SSO”) engaged in the formulation, development or publica
12、tion of standards (whether designated as a standard, specification, recommendation or otherwise), whether such reference consists of mandatory, alternate or optional elements (as defined in the TIA Engineering Manual, 4thedition) then (i) TIA disclaims any duty or obligation to search or investigate
13、 the records of any other SSO for IPR or letters of assurance relating to any such Normative Reference; (ii) TIAs policy of encouragement of voluntary disclosure (see Engineering Manual Section 6.5.1) of Essential Patent(s) and published pending patent applications shall apply; and (iii) Information
14、 as to claims of IPR in the records or publications of the other SSO shall not constitute identification to TIA of a claim of Essential Patent(s) or published pending patent applications. TIA does not enforce or monitor compliance with the contents of the Document. TIA does not certify, inspect, tes
15、t or otherwise investigate products, designs or services or any claims of compliance with the contents of the Document. ALL WARRANTIES, EXPRESS OR IMPLIED, ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION, ANY AND ALL WARRANTIES CONCERNING THE ACCURACY OF THE CONTENTS, ITS FITNESS OR APPROPRIATENESS FOR
16、 A PARTICULAR PURPOSE OR USE, ITS MERCHANTABILITY AND ITS NONINFRINGEMENT OF ANY THIRD PARTYS INTELLECTUAL PROPERTY RIGHTS. TIA EXPRESSLY DISCLAIMS ANY AND ALL RESPONSIBILITIES FOR THE ACCURACY OF THE CONTENTS AND MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE CONTENTS COMPLIANCE WITH ANY APPL
17、ICABLE STATUTE, RULE OR REGULATION, OR THE SAFETY OR HEALTH EFFECTS OF THE CONTENTS OR ANY PRODUCT OR SERVICE REFERRED TO IN THE DOCUMENT OR PRODUCED OR RENDERED TO COMPLY WITH THE CONTENTS. TIA SHALL NOT BE LIABLE FOR ANY AND ALL DAMAGES, DIRECT OR INDIRECT, ARISING FROM OR RELATING TO ANY USE OF T
18、HE CONTENTS CONTAINED HEREIN, INCLUDING WITHOUT LIMITATION ANY AND ALL INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS, LOSS OF PROFITS, LITIGATION, OR THE LIKE), WHETHER BASED UPON BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING NEGLIGENCE), PR
19、ODUCT LIABILITY OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE FOREGOING NEGATION OF DAMAGES IS A FUNDAMENTAL ELEMENT OF THE USE OF THE CONTENTS HEREOF, AND THESE CONTENTS WOULD NOT BE PUBLISHED BY TIA WITHOUT SUCH LIMITATIONS. ANSI/TIA-4966 i Telecommunications Infrastructure
20、 Standard for Educational Facilities Table of Contents FOREWORD . v 1 SCOPE 1 2 NORMATIVE REFERENCES . 1 3 DEFINITIONS, ACRONYMS AND ABBREVIATIONS, UNITS OF MEASURE 2 3.1 General 2 3.2 Definitions 2 3.3 Acronyms and abbreviations 8 3.4 Units of measure 9 4 TOPOLOGY 10 4.1 Balanced twisted-pair cabli
21、ng .10 4.2 Optical fiber cabling 10 4.3 Broadband coaxial cabling 10 4.4 Star topology .10 4.4.1 General 10 4.4.2 Cabling directly between telecommunications rooms/telecommunications enclosures .11 4.4.3 Centralized optical fiber cabling .11 5 BACKBONE CABLING (CABLING SUBSYSTEM 2 AND CABLING SUBSYS
22、TEM 3) . 13 5.1 General .13 5.2 Length .13 5.3 Recognized media 13 6 HORIZONTAL CABLING (CABLING SUBSYSTEM 1) . 14 6.1 General .14 6.2 Length .15 6.3 Recognized media 15 6.4 Bundled and hybrid cables 15 7 WORK AREA 16 7.1 General .16 7.2 Work area cords .16 7.3 Multi-user telecommunications outlet a
23、ssembly (MUTOA) 16 7.3.1 General 16 7.3.2 Application planning .17 ANSI/TIA-PN-4966 ii 7.3.3 Administration 17 7.3.4 Maximum work area cord lengths 17 7.3.4.1 Balanced twisted-pair cabling .17 7.3.4.2 Optical fiber cabling 18 7.3.4.3 Broadband coaxial cabling 18 7.4 Consolidation point .19 7.4.1 Gen
24、eral 19 7.4.2 Application planning .20 8 BAS CABLING . 21 9 TELECOMMUNICATIONS SPACES . 22 9.1 General .22 9.2 Location of cross-connects .22 9.2.1 General 22 9.2.2 Horizontal cross-connect .22 9.3 Telecommunications room 22 9.3.1 General 22 9.3.2 Size .22 9.3.3 Quantity .22 9.3.4 Standby power .22
25、9.4 Telecommunications enclosure .22 9.5 Equipment room .23 9.5.1 General 23 9.5.2 Access .23 9.5.3 Design .23 9.5.3.1 Size 23 9.5.3.2 Heating, ventilation and air conditioning (HVAC) .23 9.5.3.3 Electrical .23 9.5.3.3.1 General 23 9.5.3.3.2 Standby power .23 9.6 Entrance room or space 24 9.7 Teleco
26、mmunications outlet spaces .24 9.8 Multi-user telecommunications outlet assembly (MUTOA) space 24 9.9 Consolidation point space .24 9.10 Multi-tenant building spaces 24 ANSI/TIA-4966 iii 9.10.1 General 24 9.10.2 Planning .25 9.10.3 Common telecommunications room .26 9.10.4 Common equipment room 26 9
27、.10.4.1 General .26 9.10.4.2 Location 26 9.10.4.3 Pathways 26 9.10.4.4 Quantity 26 10 BUILDING PATHWAYS . 27 10.1 General .27 10.2 Pathways supporting tenant spaces 27 10.3 Pathways in tenant spaces .28 10.4 Building security pathway considerations for tenant spaces 29 11 WIRELESS ACCESS POINTS . 30
28、 11.1 General .30 11.2 Coverage areas 30 11.3 Density 30 11.4 Cabling infrastructure 30 11.5 Mounting height 30 12 FIRESTOPPING 31 13 INSTALLATION REQUIREMENTS 31 14 GROUNDING AND BONDING . 31 15 ADMINISTRATION . 31 16 CABLING REQUIREMENTS 31 Annex A (informative) Typical classroom layouts 32 Annex
29、B (informative) Bibliography 36 List of Figures Figure 1 Illustrative relationship between relevant TIA standards vi Figure 2 Representative model for an educational facility telecommunications infrastructure ix Figure 3 Elements of generic cabling topology 3 Figure 4 Example of star topology 11 Fig
30、ure 5 Centralized optical fiber cabling 12 Figure 6 Typical horizontal and work area cabling using a star topology 14 Figure 7 Application of a multi-user telecommunications outlet assembly 17 ANSI/TIA-PN-4966 iv Figure 8 Application of consolidation point .20 Figure 9 Example of pathways and spaces
31、 in a multi-tenant building .25 Figure 10 Example of additional pathways .27 Figure 11 Example of dedicated pathways for tenant spaces .28 Figure 12 Typical classroom 32 Figure 13 Classroom with presentation podium 33 Figure 14 Typical computer lab 34 Figure 15 Typical science lab .35 List of Tables
32、 Table 1 Conduit sizes 4 Table 2 Maximum length of horizontal cables and work area cords 18 Table 3 WAP density for places of assembly30 ANSI/TIA-4966 v FOREWORD This Standard was developed by TIA Subcommittee TR-42.1. Approval of this Standard This Standard was approved by TIA Subcommittee TR-42.1,
33、 TIA Engineering Committee TR-42, and the American National Standards Institute (ANSI). ANSI/TIA reviews standards every 5 years. At that time, standards are reaffirmed, withdrawn, or revised according to the submitted updates. Updates to be included in the next revision should be sent to the commit
34、tee chair or to ANSI/TIA. Contributing organizations More than 30 organizations within the telecommunications industry contributed their expertise to the development of this Standard (including manufacturers, consultants, end users, and other organizations). Documents superseded None. Significant te
35、chnical changes from the previous edition Not applicable Relationship to other TIA standards and documents The following are related standards regarding various aspects of structured cabling that were developed and are maintained by Engineering Committee TIA TR-42. An illustrative diagram of the rel
36、ationship to other relevant TIA standards is given in figure 1. Generic Telecommunications Cabling for Customer Premises (ANSI/TIA-568-C.0) Commercial Building Telecommunications Cabling Standard (ANSI/TIA-568-C.1) Balanced Twisted-Pair Telecommunications Cabling And Components Standard (ANSI/TIA-56
37、8-C.2) Optical Fiber Cabling Components Standard (ANSI/TIA-568-C.3) Broadband Coaxial Cabling and Components Standard (ANSI/TIA-568-C.4) Telecommunications Pathways and Spaces (ANSI/TIA-569-C) Residential Telecommunications Infrastructure Standard (ANSI/TIA-570-C) Administration Standard for Telecom
38、munications Infrastructure (ANSI/TIA-606-B) Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises (ANSI/TIA-607-B) Customer-Owned Outside Plant Telecommunications Infrastructure Standard (ANSI/TIA-758-B) Building Automation Systems Cabling Standard (ANSI/TIA-862-A) Teleco
39、mmunications Infrastructure Standard for Data Centers (ANSI/TIA-942-A) Telecommunications Infrastructure Standard for Industrial Premises (ANSI/TIA-1005-A) Healthcare Facility Telecommunications Infrastructure Standard (ANSI/TIA-1179) ANSI/TIA-PN-4966 vi C o m m o n S t a n d a r d sA N S I / T I A
40、- 5 6 8 . 0( G e n e r i c )P r e m i s e s S t a n d a r d sA N S I / T I A - 5 6 8 . 1( C o m m e r c i a l )A N S I / T I A - 5 6 8 . 2( B a l a n c e d t w i s t e d -p a i r )A N S I / T I A - 5 6 9( P a t h w a y s a n d s p a c e s )A N S I / T I A - 5 7 0( R e s i d e n t i a l )C o m p o n
41、e n t S t a n d a r d sA N S I / T I A - 5 6 8 . 3( O p t i c a l f i b e r )A N S I / T I A - 6 0 6( A d m i n i s t r a t i o n )A N S I / T I A - 9 4 2( D a t a c e n t e r s )A N S I / T I A - 5 6 8 . 4( B r o a d b a n d c o a x i a l )A N S I / T I A - 1 0 0 5( I n d u s t r i a l )A N S I / T
42、 I A - 6 0 7( B o n d i n g a n d g r o u n d i n g e a r t h i n g )A N S I / T I A - 1 1 7 9( H e a l t h c a r e )A N S I / T I A - 7 5 8( O u t s i d e p l a n t )A N S I / T I A - 8 6 2( B u i l d i n g a u t o m a t i o n s y s t e m s )A N S I / T I A - 4 9 6 6( E d u c a t i o n a l )Figure
43、1 Illustrative relationship between relevant TIA standards The following documents may also be useful to the reader: National Electrical Safety Code (NESC) (IEEE C2-2012) National Electrical Code (NEC) (NFPA 70-2014) Information Transport Systems Design Standard for K-12 Educational Institutions (AN
44、SI/BICSI 001-2009) Due to the life, health and safety aspects of educational facilities, there may be a substantial number of authorities having jurisdiction (AHJs). Designers and installers are encouraged to thoroughly research the requirements established by these AHJs. Useful supplements to this
45、Standard are the most current revisions of the following BICSI doc-uments: Telecommunications Distribution Methods Manual, Outside Plant Design Reference ANSI/TIA-4966 vii Manual, and Information Technology Systems Installation Methods Manual. These manuals provide practices and methods by which man
46、y of the requirements of this Standard are imple-mented. Other references are listed in Annex B. Annexes There are two annexes to this Standard. Annexes A and B are informative and not considered requirements of this Standard. Introduction This Standard specifies a telecommunications cabling system
47、for educational buildings and spaces that will support a multi-product, multi-vendor environment. It also provides information that may be used for the design of telecommunications products for these enterprises. Purpose The purpose of this Standard is to enable the planning and installation of a st
48、ructured cabling system for educational buildings and spaces. Installation of cabling systems during building construction or renovation is typically easier and less disruptive than after the building is occu-pied. This applies, in particular, to operating facilities that will have additional restri
49、ctions on ac-cess to spaces and areas after occupancy. Selection of media and network design is of particu-lar importance for larger educational facilities, which may have a useful life far longer than tradi-tional office-oriented commercial buildings. This Standard establishes performance and technical criteria for various cabling system configu-rations for accessing and connecting their respective elements. In order to determine the re-quirements of a generic cabling system, performance requirements for vari