ANSI UL 603-2008 UL Standard for Safety Power Supplies for Use with Burglar-Alarm Systems (Fifth Edition Reprint with Revisions Through and Including July 06 2018)《防盗报警系统电源的标准》.pdf

上传人:proposalcash356 文档编号:439332 上传时间:2018-11-14 格式:PDF 页数:78 大小:852.15KB
下载 相关 举报
ANSI UL 603-2008 UL Standard for Safety Power Supplies for Use with Burglar-Alarm Systems (Fifth Edition Reprint with Revisions Through and Including July 06 2018)《防盗报警系统电源的标准》.pdf_第1页
第1页 / 共78页
ANSI UL 603-2008 UL Standard for Safety Power Supplies for Use with Burglar-Alarm Systems (Fifth Edition Reprint with Revisions Through and Including July 06 2018)《防盗报警系统电源的标准》.pdf_第2页
第2页 / 共78页
ANSI UL 603-2008 UL Standard for Safety Power Supplies for Use with Burglar-Alarm Systems (Fifth Edition Reprint with Revisions Through and Including July 06 2018)《防盗报警系统电源的标准》.pdf_第3页
第3页 / 共78页
ANSI UL 603-2008 UL Standard for Safety Power Supplies for Use with Burglar-Alarm Systems (Fifth Edition Reprint with Revisions Through and Including July 06 2018)《防盗报警系统电源的标准》.pdf_第4页
第4页 / 共78页
ANSI UL 603-2008 UL Standard for Safety Power Supplies for Use with Burglar-Alarm Systems (Fifth Edition Reprint with Revisions Through and Including July 06 2018)《防盗报警系统电源的标准》.pdf_第5页
第5页 / 共78页
亲,该文档总共78页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 603 Power Supplies for Use with Burglar- Alarm SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AU

2、THORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Power Supplies for Use with Burglar-Alarm Systems, UL 603 Fifth Edition, Dated February 18, 2008 Summary of Topics This revision to ANSI/UL 603 is being issued to incorporate the following and to

3、update the ANSI approval date of the standard. Modication of Table 26.1 to add Access Control System Units Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in

4、 the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated March 2, 2012. All rights reserved. No part of thi

5、s publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including bu

6、t not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inab

7、ility to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Stan

8、dards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers compu

9、ter system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and

10、that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 22, 2013 UL 603 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 22, 2013 UL 603 tr2 No Text on This Pa

11、geUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 18, 2008 (Title Page Reprinted: January 22, 2013) 1 UL 603 Standard for Power Supplies for Use with Burglar-Alarm Systems First Edition June, 1980 Second Edition January, 1987 Third

12、Edition March, 1993 Fourth Edition March, 1998 Fifth Edition February 18, 2008 This ANSI/UL Standard for Safety consists of the Fifth edition including revisions through January 22, 2013. The most recent designation of ANSI/UL 603 as an American National Standard (ANSI) occurred on January 22, 2013.

13、 ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collabo

14、rative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and

15、exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 603-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 18, 2008 POWER SUPPLIES FOR USE WITH BURGLAR-ALARM SYSTEMS - UL 603 2 No Text on This PageUL COP

16、YRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .6 2 General 7 2.1 Components .7 2.2 Units of measurement .8 2.3 Undated references .8 2.4 Terminology .8 3 Glossary .8 4 Installation and Operating Instructions .9 CONS

17、TRUCTION ASSEMBLY 5 Protection of Service Personnel .9 5.1 General .9 5.2 Electric shock .10 6 Test Features .10 7 Enclosures 10 7.1 General 10 7.2 Doors, covers, and guards 12 7.3 Openings .12 7.4 Cast metal enclosures .18 7.5 Sheet metal enclosures 18 7.6 Nonmetallic enclosures .21 7.7 Screens and

18、 expanded metal .21 8 Protection Against Corrosion 22 FIELD WIRING CONNECTIONS 9 Cord-Connected Products .22 9.1 General 22 9.2 Cord grip (strain relief) .23 10 Permanently Connected Products .23 10.1 General .23 10.2 Field wiring compartment 24 10.3 Field wiring terminals .24 10.4 Polarity identica

19、tion 27 11 Grounding .27 INTERNAL WIRING 12 General 28 13 Wiring Methods .29 13.1 Wireways 29 13.2 Splices 29 13.3 Printed wiring assemblies .29 13.4 Separation of circuits .29 14 Bonding for Grounding 30 FEBRUARY 18, 2008 POWER SUPPLIES FOR USE WITH BURGLAR-ALARM SYSTEMS - UL 603 3UL COPYRIGHTED MA

20、TERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL ELECTRICAL COMPONENTS 15 General 32 15.1 Mounting of parts 32 15.2 Current-carrying parts .32 15.3 Batteries 32 15.4 Semiconductors 33 15.5 Switches 33 15.6 Transformers, coils, and relays .33 16 Insulating Mat

21、erials .33 17 Bushings 34 18 Overcurrent Protection 35 SPACINGS 19 General 35 PERFORMANCE 20 General 38 20.1 Test units and data .38 20.2 Additional tests 38 20.3 Test samples and miscellaneous data 38 20.4 Test voltages 39 21 Dielectric Voltage-Withstand Test .39 22 Overvoltage and Undervoltage Tes

22、ts 40 23 Current Overload Test .41 24 Limited Output Test .41 25 Power-Limited Circuits .42 25.1 General .42 25.2 Maximum voltage 44 25.3 Maximum current .45 25.4 VA max (Not inherently limited circuits only) .45 26 Standby Power Tests .45 27 Extended Power Failure Tests 47 28 Transfer to Standby Te

23、st 47 29 Charging Current Test for Rechargeable Batteries 47 30 Battery Tests .48 31 Multiple Purpose Power Supply .48 32 Input Test 49 33 Electrical Supervision Test .49 34 Variable Ambient Temperature Test .49 35 Humidity Test 49 36 Electric Shock Current Test 50 37 Leakage Current Test .54 38 End

24、urance Test 57 39 Jarring Test 57 40 Vibration Test 58 41 Temperature Rise Test 59 42 Abnormal Operation Test 62 43 Electrical Transient Tests 62 43.1 General .62 43.2 Supply line transients .62 FEBRUARY 18, 2008 POWER SUPPLIES FOR USE WITH BURGLAR-ALARM SYSTEMS - UL 603 4UL COPYRIGHTED MATERIAL NOT

25、 AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 43.3 Internally induced transients .63 44 Polymeric Materials Tests 63 45 Drop Test 63 46 Cord Grip (Strain Relief) Test 64 46.1 Power supply cord 64 46.2 Field wiring leads .64 47 Ignition Through Bottom-Panel Openings

26、Tests .64 47.1 General .64 47.2 Hot, aming oil .64 48 Mechanical Strength Tests for Enclosures .65 49 Special Terminal Assemblies Tests .65 49.1 General .65 49.2 Disconnection and reconnection .66 49.3 Mechanical secureness .66 49.4 Flexing test 66 49.5 Millivolt drop test .66 49.6 Temperature rise

27、test .67 MANUFACTURING AND PRODUCTION TESTS 50 General 67 51 Production Line Dielectric Voltage-Withstand Test 67 52 Production Line Grounding Continuity Test .68 MARKING 53 General 68 53.1 Details 68 53.2 Marking permanency .70 ACCESSORY EQUIPMENT 54 General 71 55 Construction .71 56 Performance (I

28、nstallation) Test .72 57 Markings .72 APPENDIX A Standards for Components .A1 FEBRUARY 18, 2008 POWER SUPPLIES FOR USE WITH BURGLAR-ALARM SYSTEMS - UL 603 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requir

29、ements cover: a) Power supplies for use with burglar-alarm systems installed in accordance with the Standard for Installation and Classication of Burglar and Holdup Alarm Systems, UL 681; and b) Power supplies used to provide electrical power and standby power for burglar-alarm equipment constructed

30、 in accordance with the following: 1) The Standard for Police Station Connected Burglar Alarm Units and Systems, UL 365; 2) The Standard for Local Burglar-Alarm Units and Systems, UL 609; 3) The Standard for Central-Station Alarm Services, UL 827; 4) The Standard for Holdup Alarm Units and Systems,

31、UL 636; 5) The Standard for Intrusion-Detection Units, UL 639; 6) The Standard for Household Burglar-Alarm System Units, UL 1023; 7) The Standard for Antitheft Alarms and Devices, UL 1037; 8) The Standard for Proprietary Burglar Alarm Units and Systems, UL 1076; 9) The Standard for Central-Station B

32、urglar-Alarm Units, UL 1610; 10) The Standard for Digital Alarm Communicator System Units, UL 1635. 1.2 The input ratings of power supplies covered by these requirements are not more than 300 volts and the output ratings are low-voltage, power-limited. See 3.2. 1.3 These requirements cover power sup

33、plies for use as components in burglar-alarm system units. 1.4 These requirements do not cover power supplies for use at a central station. Such power supplies are covered by the Standard for Central-Station Alarm Services, UL 827. 1.5 These requirements do not cover power supplies integral with a b

34、urglar-alarm system unit, nor do they cover separate power supplies intended for use with a specic unit. These are covered by the standards specied in 1.1. 1.6 These requirements do not cover power supplies for use in hazardous locations, as dened in the National Electrical Code, NFPA 70. FEBRUARY 1

35、8, 2008 POWER SUPPLIES FOR USE WITH BURGLAR-ALARM SYSTEMS - UL 603 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 1.7 These requirements do not cover power supplies covered by the Standard for Power Units Other Than Class 2, UL 1012, or ba

36、ttery chargers covered by the Standard for Battery Chargers for Charging Engine-Starter Batteries, UL 1236. 1.8 With reference to 1.1, the Standard for Police Station Connected Burglar Alarm Units and Systems, UL 365; the Standard for Local Burglar Alarm Units and Systems, UL 609; the Standard for P

37、roprietary Burglar Alarm Units and Systems, UL 1076; the Standard for Central-Station Burglar-Alarm Units, UL 1610; and the Standard for Digital Alarm Communicator System Units, UL 1635, contain requirements for attack resistance against a power supply providing energy to a local audible alarm sound

38、ing device or to a device that will transmit a signal from the protected area to a remote location, such as a central station or police station. A power supply complying with the requirements of this standard that is to be used for any of these purposes shall be capable of being mounted inside an en

39、closure that will provide the required attack resistance, or shall be provided with an enclosure that will provide the required attack resistance. See UL 365, UL 609, UL 1076, UL 1610, and UL 1635 to determine the attack resistance requirements that will apply. 2 General 2.1 Components 2.1.1 Except

40、as indicated in 2.1.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard. 2.1.2 A component is not required to comply with a speci

41、c requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its rating established for the intended cond

42、itions of use. 2.1.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic condition

43、s. FEBRUARY 18, 2008 POWER SUPPLIES FOR USE WITH BURGLAR-ALARM SYSTEMS - UL 603 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2 Units of measurement 2.2.1 Values stated without parentheses are the requirement. Values in parentheses are

44、explanatory or approximate information. 2.2.2 Unless otherwise indicated, all voltage and current values mentioned in this standard are root-mean-square (rms). 2.3 Undated references 2.3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted

45、 as referring to the latest edition of that code or standard. 2.4 Terminology 2.4.1 The term product as used in these requirements refers to all power supplies or any part thereof covered by these requirements unless specically noted otherwise. 3 Glossary 3.1 For the purpose of these requirements, t

46、he following denitions apply. 3.2 CIRCUITS, ELECTRICAL: a) HIGH-VOLTAGE (CLASS 1) A circuit involving a potential of not more than 300 volts and having circuit characteristics in excess of those of a low-voltage, power-limited circuit. b) LOW-VOLTAGE A circuit involving a potential of not more than

47、30 volts AC rms (42.4 volts DC or AC peak). c) POWER-LIMITED A circuit whose output is limited as specied in Power-Limited Circuits, Section 25. d) CLASS2Acircuit in which the voltage and power limitations are in accordance with the requirements of Table 25.1 for AC circuits and Table 25.2 for DC ci

48、rcuits. e) CLASS3Acircuit in which the voltage and power limitations are in accordance with the requirements of Table 25.1 for AC circuits and Table 25.2 for DC circuits. 3.3 CORD-CONNECTED PRODUCT A product intended for connection to the power source by means of a supply cord. By its nature, such a

49、 product is intended to be moved for reasons of interchange or relocation of the products of a system. 3.4 LINE-VOLTAGE The voltage at any eld connected source of supply, nominally 50 60 hertz; 115, 208, or 230 volts. 3.5 SAFETY CIRCUIT Any circuit that is intended to reduce the risk of re, electric shock, or unintentional contact with moving parts that may cause injury to persons, such as an interlock circuit. FEBRUARY 18, 2008 POWER SUPPLIES FOR USE WITH BURGLAR-ALARM SYSTEMS - UL 603 8UL

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1