1、MIL-D-5 1410(EA) AMENDMENT 1 22 February 1989 Characteristics Requirements Minimum Maximum Absorbance, percent of standard 97.5 - Melting point, “C 147 156 Solids content, percent by weight 50 - MILITARY SPECIFICATION Test paragraph 4.2.4.1 4.2.4.2. 4.2.4.3 DYE, GREEN, ETHYL-BIS(2,4-DINITROPHENYL) A
2、CETATE Xkis amendment forms a part of MIGD-S1410(EA), dated 22 October 1974, and is approved for use by the U.S. Army Chemical Research, Development and Engineering Center, De- partment of the Army and is available for use by all Departments and Agencies of the Department of Defense. PAGE 2 3.1: Del
3、ete Table 1 in its entirety and substitute the following: AMSC NIA FSC 6820 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. 1 of 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - - MIL-D-5141Q (1) b m 979970b 0121
4、95 T 9 ih MIGD-5 14 1 O (EA) AMENDMENT 1 PAGE 3 3.2: Add the following: “The dye used in making the paper shall pass through a 44 micron (No. 325) sieve with not more than 15 percent by weight retained on the sieve.” PAGE 4 4.2.2,2: Delete 4,2.2.2 and table N in their entirety and substitute the fol
5、lowing: 4.22.2 For test, Each drum shall be tested for solids content. Sampling for all other tests shall be conducted by making a composite from the dried samples obtained from the solids content tests. The composite sample shall be tested in duplicate.” PAGE 5 4.2.4.1 : Line 1 : Delete “Molar abso
6、rbtivity” and substitute “absorbance” and add the fol- lowing as the first sentence in the paragraph: “Determine the absorbance of the standard sample (see 6.7) and test the sample as follows:” I Lines 13 through 15: Delete this calculation in its entirety and substitute the follow- ing: u Absorbanc
7、e of sample Weight standard Absorbance of standard Weight sample ” Percent absorbance = X 4.2,4.3: Delete in its entirety and substitute the following: “4,2.4.3 Solids content. Weigh to the nearest milligram approximately log of specimen into a tared open dish. Dry to constant weight at 115 =t 5C. C
8、ool and weigh specimen and dish to the nearest milligram. Calculate the percent solids as follows: B-C (100) A-C Percent solids = - where: A = weight of specimen and dish before heating, in grams B = weight of specimen and dish after heating, in grams C = weight of dish, in grams ” 2 Provided by IHS
9、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D-SLLILO (2) 68 W 7977706 OL2L876 L = MIL-D-5 141 O (EA) AMENDMENT 1 PAGE 6 4.2.4.4: Delete in its entirety. PAGE 7 5.1: Delete first sentence and substitute the following: “A quantity of 200 (+5) pounds of dye sh
10、all be packed in a 3 mil polyethylene liner in a nominal 30 gallon capacity 24 gauge steel drum furnished with a gasketed, fully removable cover. One tail drum containing less than 200 pounds is permissible, per lot.” 5.2 (e): Add the following; “percent solids, pounds dye”. PAGE 8 Section 6: Add th
11、e following: “6.7 Standard sample. A standard dye sample for use in the absorbance test may be obtained from Commander, U.S. Army Armament, Munitions and Chemical Com- mand, Product Assurance Directorate, Chemical Systems Division, Detection Branch, Aberdeen Proving Ground, MD 21010-5423, refer to Dye Green EDA Standard 45161. I - Custodian: Preparing activity: Army - EA Army -. EA Project No. 6820-Al06 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-