1、 INCH - POUND MIL - PRF - 49471/1A(CR) 30 November 2000 Superseding MIL - PRF - 49471/1(ER) 2 June 1995 PERFORMANCE SPECIFICATION SHEET BATTERY, NON - RECHARGEABLE, HIGH PERFORMANCE, BA - X599/U This specification sheet is approved for use within the Communications Electronics Command, Department of
2、 the Army, and is available for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product herein shall consist of thi s specification and MIL -PRF - 49471(CR). Figure 1. Battery dimensions and terminal markings . AMSC N/A 1 of 5 FSC 6135 DISTRIBUTIO
3、N STATEMENT A . Approved for publi c release; distribution is unlimited. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL - PRF - 49471/1A(CR) 2 NOTES : 1. All dimensions are i
4、n inches. 2. Tolerances, unless otherwise specified, are - .063, +.000. 3. The battery terminal shall consist of a miniature circular battery connector, Dwg SC - C -179492, except as noted herein. 4. Connector socket body configuration shall accept two (2) each 0.156 inch minimum diameter guideposts
5、 as shown. Depth of cavity shall be 0.657 inch minimum. 5. The socket shall be supported and mounted so that the top surface of th e socket shall not protrude above the adjacent outside surface of the jacket and shall not be more than 1/16 inch below adjacent outside surface of the jacket when used
6、initially, during, and after subsequent insertions of the mating plug during contractua l testing. REQUIREMENTS : Dimensions and configuration: See Figure 1. Maximum voltage: 9.90 volts. Cut - off voltage for capacity: 6.00 volts Terminals: Six (6) hole socket type with no obstructions of any holes
7、(see notes 3 and 5). Weight (maximu m): 1.5 pounds (680 grams). Charge protection: Applicable. Battery Short Circuit Test: Applicable. State of Charge Indicator: Not applicable High temperature protection: Applicable. Complete discharge device: Applicable. Capacity tests: When the battery is tested
8、in accordance with the methods of examination and tests of this specification, the minimum capacity test requirements shall be as specified below: Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without licen
9、se from IHS-,-,-MIL-PRF-49471/1A(CR) 3 Capacity Test Minimum Capacity Requirements in Hours to 6.00 Volts I 3.2 L 1.7 H 6.2 HT 6.0 LT 1.6 IT 3.0 LR1 47.0 Initial voltage delay: During the I, H, HT, and IT discharge tests, initial voltages below 6.0 volts cannot exceed a 5.0 second duration. During t
10、he L and LT discharge tests initial voltages below 5.70 vo lts cannot exceed a 60.0 second duration. Connector: The connector configuration and operating temperature range requirements shall be certified in the First Article Test Report. The connector shall be in accordance with SC - C -179492 with
11、the following e xceptions: (1) Sheet two of SC - C - 179492 does not apply. (2) Mounting screws are optional. (3) Operating temperature range for the connector shall be from a low of - 55 o C to a high of 125 o C. (4) The connector test described in paragraph 4.7.15 shall be pe rformed 10 times with
12、 SM - D - 687888. (5) Each of the metallic sockets in the connector (top view) shall conform to Figure 2. Each socket shall be cylindrical in shape and may have a single gap with a maximum opening of 30 degrees. The socket shall accept a number 16 pin. Figure 2. Socket (Top View) Copyright Communica
13、tions - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49471/1A(CR) 4 METHODS OF EXAMINATION AND TESTS : Capacity tests: (1) Storage: Details on storage conditions for all capacity tests are specif
14、ied in the basic specification. (2) Discharge: Cells (forced discharge): Two cells shall be discharged at 2.0 amperes at 70 + 5 o F to 2.0 volts Each discharged cell shall then be connected in series to two fresh cells. Each string shall be force discharged at 2.0 amperes at 70 + 5 o F for 3.2 hours
15、. Batteries: For all capacity te sts, except the LR1, H and HT, the batteries shall be discharged at 2.0 amperes constant current to cut - off volts (zero volts for the I test). For the H and HT capacity tests the batteries shall be discharged through 2.0 amperes constant current for five minutes fo
16、llowed by open circuit for five minutes. This cycle shall be repeated until the closed - circuit voltage reaches cut -off volts. For the LR1 test, batteries shall be discharged at 135 milliamperes to 6.5 volts, then at 1.7 watts to 1.0 volt. For ced discharge: After discharge to zero volts on the I
17、capacity test, the batteries shall be force discharged at 2.0 amperes for a minimum of 5 minutes. Overload test: Batteries shall be discharged at 4.0 amperes. Abuse test predischarge: Designated sampl es shall be discharged at 2.0 amperes for 1.6 hours. Abuse test, pulse discharge: Batteries shall b
18、e discharged at 2.5 amperes for 1 minute followed by 1.8 amperes for 4 minutes, cycled continuously to cut - off voltage. Closed - circuit voltage test (Batter y & cell string tests): Load resistance of 3 ohms shall be used. Voltage shall be above 6.00 volts within 10.0 seconds. Cell closed - circui
19、t voltage test: Load resistance of 1 ohm shall be used. Voltage shall be above 2.0 volts in 5 seconds. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49471/1A(CR) 5 Margi
20、nal n otations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodian: Preparing Activity: Army - CR Army - CR (Project 6135 - 0417 - 01) Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-