1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM ASD-STAN prEN 4612-003 Edition P 2 March 2018 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Rue Montoyer 10 - 1000 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.org ICS: Supersedes edition
2、P 1 of March 2005 and will supersede EN 4612-003:2011 Descriptors: ENGLISH VERSION Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Jacketed or screened and jacketed Part 003: Tin plated copper Operating temperatures, between 65 C and 135 C Single
3、 extruded wall for open applications, with jacket without screen UV laser printable Product standard Luft- und Raumfahrt Ein- und mehradrige elektrische Leitungen fr allgemeine Verwendung XLETFE Familie mit Mantel oder geschirmt und Mantel Teil 003: Kupfer verzinnt, Betriebstemperaturen zwischen 65
4、C und 135 C Einfach extrudierte Isolierung fr externe Verwendung, mit Mantel ohne Schirm UV-Laser bedruckbar Produktnorm Srie arospatiale Cbles, lectriques, dusage gnral, mono et multiconducteurs Famille XLETFE Gains ou blinds et gains Partie 003 : Cuivre tam Tempratures de fonctionnement comprises
5、entre 65 C et 135 C Fil simple isol pour applications externes, gain et non blind Marquable au laser UV Norme de produit This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is pu
6、blished for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected,
7、 physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, the ASD-STAN prEN will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation t
8、o full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. ASD-STAN Technical Committee approves that: “This document is published by ASD
9、-STAN for the needs of the European Aerospace Industry. The use of this standard is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” ASD-STAN reviews each standard and techn
10、ical report at least every five years at which time it may be revised, reaffirmed, stabilized or cancelled. ASD-STAN invites you to send your written comments or any suggestions that may arise. All rights reserved. No parts of this publication may be reproduced, stored in a retrieval system or trans
11、mitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of ASD-STAN. Order details: E-mail: salesasd-stan.org Web address: http:/www.asd-stan.org/ Edition approved for publication 1st March 2018 Comments should be sent with
12、in six months after the date of publication to ASD-STAN Electrical Domain Copyright 2018 ASD-STAN prEN 4612-003:2018 (E) 2 Contents Page Foreword 2 1 Scope 3 2 Normative references 3 3 Terms, definitions and symbols . 3 4 Materials and construction . 4 5 Required characteristics 5 6 Quality assuranc
13、e 7 7 Designation . 7 8 Identification and marking 7 9 Packaging, labelling and delivery lengths 7 10 Technical specification . 7 Foreword This standard was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules
14、 of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 4612-003:2018 (E) 3 1 Scope This standard specifies the characteristics of UV laser printable jacket, tin plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro E
15、thylene co-polymer (XLETFE) family for use in the on board electrical systems of aircraft operating at temperatures between 65 C and 135 C, operating at voltages not exceeding 600 V rms at sea level. and frequencies not exceeding 2 000 Hz. This insulation system has been used in aerospace applicatio
16、ns using 115 V (phase-to-neutral) 400 Hz ac and 28 Vdc. Verification of the suitability of cables for use in other electrical systems is the responsibility of the user. These jacketed cables are suitable for airframe use without additional protection when the jacket is present. When the jacket is st
17、ripped back the cores may need additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence. 2 Normative references The following documents are referred to in the text in such a way that some or all of their c
18、ontent constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2235, Aerospace series Single and multicore electrical cables, screened and jacketed Te
19、chnical specification EN 3475-100 (all parts), Aerospace series Cables, electrical, aircraft use Test methods Part 100: General EN 4611-002, Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Part 002: General EN 4611-003, Aerospace series Cables, e
20、lectrical, for general purpose, single and multicore assembly XLETFE Family Part 003: Tin plated copper Operating temperatures, between 65 C and 135 C Single extruded wall for enclosed applications UV laser printable Product standard EN 4612-002, Aerospace series Cables electrical, for general purpo
21、se, single and multicore assembly XLETFE Family Jacketed or screened and jacketed Part 002: General EN 9133, Aerospace series Quality Management Systems Qualification Procedure for Aerospace Standard Products 3 Terms, definitions and symbols For the purposes of this document, the terms, definitions
22、and symbols given in EN 3475-100 apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: IEC Electropedia: available at http:/www.electropedia.org/ ISO Online browsing platform: available at http:/www.iso.org/obp prEN 4612-003:2018 (E) 4 4 Material
23、s and construction 4.1 Materials These cables shall consist of the following: cores according to EN 4611-003; number of cores 2 (two) to 4 (four). Cores be twisted together according to EN 2235. Filler cores shall not be permitted. Outer jacket: it shall be possible to mark the jacket by UV laser pr
24、inting; minimum thickness for 2 (two) core shall be 0,13 mm; minimum thickness for 3 (three) core and 4 (four) core shall be 0,15 mm. 4.2 Construction See EN 4612-002 and Table 1. Table 1 Multicore without screen, with jacket Size AWG a 2 core 3 core 4 core Max. dia. Mass DC Res. Max. dia. Mass DC R
25、es. Max. dia. Mass DC Res. max. /km max. /km max. /km mm kg/km max. mm kg/km max. mm kg/km max. 001 b 26 2,04 5,34 153,5 2,17 7,59 153,5 2,38 9,79 153,5 002 b 24 2,13 6,80 109,2 2,38 9,85 109,2 2,60 13,12 109,2 004 22 2,49 9,66 61,8 2,77 14,55 61,8 3,01 19,29 61,8 006 20 2,98 15,32 34,2 3,30 22,84 3
26、4,2 3,67 29,94 34,2 010 18 3,49 21,96 21,7 3,85 33,25 21,7 4,25 43,93 21,7 012 16 3,98 28,51 16,3 4,38 42,24 16,3 4,80 56,55 16,3 020 14 4,54 41,20 11,2 4,99 61,23 11,2 6,00 85,73 11,2 030 12 5,47 61,37 7,0 5,99 92,26 7,0 7,09 128,78 7,0 a AWG Closest American Wire Gauge. b Tin plated copper alloy c
27、onductor. 4.3 Colour coding of cores See EN 4612-002. prEN 4612-003:2018 (E) 5 5 Required characteristics According to EN 4612-002, EN 2235 and EN 3475-100. See Table 2. NOTE Tests EN 3475-302 to EN 3475-706 shall be performed on the single core cable. Table 2 Tests (1 of 3) EN 3475- Designation of
28、the test Details 201 Visual examination Applicable 202 Mass Applicable, see Table 1. 203 Dimensions Applicable, see Table 1. 301 Ohmic resistance per unit length Applicable, see Table 1. 302 Voltage proof test Not applicable 303 Insulation resistance Not applicable 304 Surface resistance Not applica
29、ble 305 Overload resistance Not applicable 401 Accelerated ageing Applicable Temperature (200 3) C 402 Shrinkage and delamination Applicable Temperature (150 5) C Maximum shrinkage at each end of cable: Jacket: 2 mm on sizes 001 to 010, 3 mm on sizes 012 to 030. Cores: 0,80 mm on sizes 001 to 006, 1
30、,00 mm on sizes 010 to 012, 1,20 mm on sizes 020 to 030. 403 Delamination and blocking Applicable Temperature (135 5) C 404 Thermal shock Applicable Temperatures ( 65 3) C and (135 3) C Maximum shrinkage at each end of cable: Jacket: 2 mm on sizes 001 to 010, 3 mm on sizes 012 to 030. Cores: 0,80 mm
31、 on sizes 001 to 006, 1,00 mm on sizes 010 to 012, 1,20 mm on sizes 020 to 030. prEN 4612-003:2018 (E) 6 Table 2 Tests (2 of 3) EN 3475- Designation of the test Details 405 Bending at ambient temperature Applicable 406 Cold bend test Applicable Temperature ( 65 2) C 407 Flammability Applicable Metho
32、ds 1 and 2 Flame applied for 15 s Extinguishing time: 3 s max. 408 Fire resistance Not applicable 409 Air-excluded ageing Not applicable 410 Thermal endurance Not applicable 411 Resistance to fluids Applicable Volume swell not greater than 10 % Scrape not applicable 412 Humidity resistance Applicabl
33、e Method B Temperature (90 2) C Duration 672 h 413 Wrap back test Applicable 414 Differential scanning calorimeter (DSC test) Not applicable 501 Dynamic cut-through Not applicable 502 Notch propagation Not applicable 503 Scrape abrasion Not applicable 504 Torsion Not applicable 505 Tensile test on c
34、onductors and strands Applicable 506 Plating continuity Applicable 507 Adherence of plating Applicable 508 Plating thickness Not applicable 509 Solderability Applicable Wetting time 1 s max. 510 Tensile strength and elongation of extruded insulation, sheath and jacket material Applicable for jacket
35、Eb 75 % minimum TS 34 MPa minimum 511 Cable-to-cable abrasion Not applicable 512 Flexure endurance Not applicable 601 Smoke density Not applicable 602 Toxicity Not applicable 603 Resistance to wet arc tracking Not applicable prEN 4612-003:2018 (E) 7 Table 2 Tests (3 of 3) EN 3475- Designation of the
36、 test Details 604 Resistance to dry arc propagation Not applicable 605 Wet short circuit test Not applicable 701 Stripability and adherence of insulation to the conductor applicable 702 Screen pushback capability Not applicable 703 Permanence of manufacturers marking Applicable 704 Flexibility Not a
37、pplicable 705 Contrast measurement Laser Marking K 50 % 706 Laser markability Applicable 6 Quality assurance See EN 9133 and EN 4611-002. 7 Designation EXAMPLE Description block CABLE, ELECTRICAL Identity block EN4612-003A010P Number of this standard Code letter for number of cores (see EN 4612-002,
38、 Table 2) Code for nominal section (see Table 1) Code letter for colour coding of cores (see EN 4612-002) NOTE If necessary, the code I9005 shall be placed between the description block and the identity block. 8 Identification and marking See EN 4611-002. 9 Packaging, labelling and delivery lengths See EN 2235. 10 Technical specification See EN 2235.