资源描述

1、A.1ASHRAE HANDBOOKAdditions and CorrectionsThis report includes additional information, and technical errorsfound between June 15, 2010, and April 1, 2013, in the SI editionsof the 2010, 2011, and 2012 ASHRAE Handbook volumes. Occa-sional typographical errors and nonstandard symbol labels will becor

2、rected in future volumes. The most current list of Handbookadditions and corrections is on the ASHRAE web site(www.ashrae.org).The authors and editor encourage you to notify them if youfind other technical errors. Please send corrections to: HandbookEditor, ASHRAE, 1791 Tullie Circle NE, Atlanta, GA

3、 30329, ore-mail mowenashrae.org. 2010 RefrigerationCh. 1. All existing references to Table 19 should be to Table 20. Allexisting references to Table 20 should be to Table 19.p. 19.2, Eq. (4). Change twoto xwo.p. 19.7, Eq. (10). Change to t to (to t)2.2011 HVAC Applications(CD only) Table of Content

4、s, p. 2. Replace second instance of“Building Operations and Management” with “General Applications.”Contributors List. For Chapter 4, add Dennis Wessel, KarpinskiEngineering.p. 5.7, 2nd col., 2nd bulleted point. Change 15 m/s to 0.15 m/s.p. 28.8, 1st col. Under U.S. Evolutionary Power Reactor (USEPR

5、),delete “0.125 in. of water” and the parentheses around “30 Pa.”p. 35.4, end of 2nd para. It should be J= I for all conditions.p. 35.5, Eq. (17). The equation should be Fsg= (1 cos 6)/2.p. 35.10, 2nd col., 3rd para. from bottom. The slope should be0.82/0.12 = 6.78.p. 35.22, Example 7, Solution. The

6、 load collector ratio should useEq. (41).p. 35.27, Symbols. Delete the second definition for Aap.p. 36.9, Table 4. Replace the table with the one on p. A.2.p. 48.20, 2nd col. For frequency range #1, consult Table 13 for Af.In definitions for Eq. (10), refer to Table 12 for Da.p. 50.18, Example 4, So

7、lution. Change “2.2 mL/” to “2.2 mL/s.”p. 51.2, Eq. (10). Change Ta to Ta.p. 51.8, Example 3, Solution. The equation for a hydronic systemshould be as follows:O = = $324/yr (T10.7)pp. 55.12-13, Eqs. (27), (28), (30), and (31). For all four equations,the denominators of the last two terms should be b

8、 and a, not 2b and2a. Also, for Eq. (31), change the first + sign to a sign.p. 60.6, Fig. 9. Replace the figure with the one provided above.2012 HVAC Systems and Equipmentpp. 7.26-27, Figs. 36 and 38. The SI versions of these figures areprovided above.p. 19.2, Table 1. For the rightmost four columns

9、, the headingsshould be +1500, 1500, +2500, and 2500 Pa.p. 26.4, 1st col., top. Units for the results for w2and w4should bekg/kg of dry air.p. 40.19, Table 1. In fifth column, change value in row 6 to 0.0345,and in row 7 to 0.0334.p. 41.3, Fig. 3. Replace parts B and C of the graphic with the hori-z

10、ontal polymer tube shown on p. A.3.p. 44.8, Table 1. In both equations for flow and pressure, change theminuses to equals signs.p. 51.13, Table 4. For hour 6, Storage should be 1400 kW.200 26.8 0.0324 130100-0.85 0.90 -Fig. 9 Typical Layout of UVGI Fixtures for Patient Isolation Room(First et al. 19

11、99)(2011 HVAC Applications, Ch. 60, p. 9)A.2 20102012 ASHRAE Handbook Additions and Corrections (SI)Table 4 Energy Cost Percentiles from 2003 Commercial Survey(2011 HVAC Applications, Ch. 36, p. 9)Building UseWeighted Energy Cost Values, $/yr per gross square metrePercentilesMean10th 25th 50th 75th

12、90thAdministrative/professional office 5.38 8.83 14.64 20.67 27.77 16.68Bank/other financial 11.73 14.75 21.53 31.54 48.12 25.94Clinic/other outpatient health 6.57 9.36 16.47 21.85 44.46 18.73College/university 4.74 12.92 14.75 24.43 32.40 19.59Convenience store 26.70 40.37 56.62 86.33 108.93 66.42C

13、onvenience store with gas station 21.42 29.60 49.62 73.52 94.08 55.11Distribution/shipping center 2.58 3.55 5.81 9.47 14.75 7.97Dormitory/fraternity/sorority 6.24 7.43 9.36 13.89 22.93 11.52Elementary/middle school 5.81 8.40 11.73 16.90 27.99 15.93Entertainment/culture 1.51 4.52 6.03 24.22 191.82 30

14、.46Fast food 31.54 53.61 95.48 132.29 152.21 96.02Fire station/police station 1.08 5.71 12.38 18.62 30.46 14.10Government office 5.60 9.69 15.07 20.24 28.63 16.36Grocery store/food market 27.99 33.05 46.39 56.73 73.74 52.10High school 6.46 9.36 10.98 17.22 23.57 13.99Hospital/inpatient health 14.75

15、23.25 26.48 34.12 38.21 29.06Hotel 7.97 11.30 14.32 18.95 27.13 17.01Laboratory 14.42 33.26 48.65 82.24 116.36 55.76Library 8.40 11.41 14.75 25.94 31.43 18.08Medical office (diagnostic) 3.55 7.32 10.98 22.93 27.23 14.32Medical office (nondiagnostic) 6.24 8.50 11.41 15.50 20.67 12.38Mixed-use office

16、4.95 9.15 13.99 21.10 31.22 19.16Motel or inn 5.27 8.93 13.02 19.59 28.74 15.93Nonrefrigerated warehouse 0.65 1.83 4.09 8.61 15.39 6.57Nursing home/assisted living 7.86 12.06 16.36 26.59 32.19 19.16Other 1.61 5.49 10.01 19.48 25.94 14.53Other classroom education 2.26 5.38 9.90 13.56 23.04 10.33Other

17、 food sales 6.46 7.75 10.23 25.30 64.80 23.68Other food service 8.50 17.22 26.26 69.97 124.43 50.81Other lodging 5.92 6.03 12.16 18.41 29.71 13.99Other office 3.98 7.64 12.81 23.25 27.56 15.82Other public assembly 3.77 5.38 8.72 16.79 22.17 12.38Other public order and safety 10.76 12.16 16.79 36.38

18、51.02 22.17Other retail 10.44 12.81 17.12 32.08 60.28 26.16Other service 8.18 12.16 17.01 31.43 78.47 29.17Post office/postal center 3.44 8.40 11.73 15.50 20.34 11.52Preschool/daycare 4.95 8.29 11.73 16.90 28.31 13.99Recreation 3.23 5.71 9.36 14.85 25.08 12.27Refrigerated warehouse 4.09 4.09 23.79 4

19、3.06 56.51 26.37Religious worship 2.69 3.98 6.46 9.04 14.21 7.75Repair shop 2.15 3.77 6.57 12.38 15.82 8.07Restaurant/cafeteria 12.06 20.02 35.84 80.09 112.81 51.67Retail store 3.88 5.71 10.55 19.05 31.22 14.85Self-storage 0.54 1.08 2.15 2.91 5.60 2.48Social/meeting 2.05 3.55 7.10 10.98 24.43 9.58Va

20、cant 0.43 0.86 2.91 7.53 12.81 5.17Vehicle dealership/showroom 7.21 9.58 14.75 31.97 42.84 22.28Vehicle service/repair shop 3.12 5.38 8.29 14.85 22.28 11.84Vehicle storage/maintenance 0.43 1.72 5.17 12.06 21.10 8.93SUM or Mean for sector 2.80 5.81 11.41 21.53 42.30 19.38Source: Calculated based on D

21、OE/EIA preliminary 2003 CBECS microdata.20102012 ASHRAE Handbook Additions and Corrections (SI) A.3Fig. 3 Indirect Evaporative Cooling (IEC) Heat Exchanger(Courtesy Munters/Des Champs)(2012 HVAC Systems and Equipment, Ch. 41, p. 3. Replaces only parts B and C of Fig. 3.)Fig. 36 Effect of Inlet Pressure andSuperheat on Condensing Turbine(2012 HVAC Systems and Equipment, Ch. 27, p. 26)Fig. 37 Single-Stage Noncondensing Turbine Efficiency(2012 HVAC Systems and Equipment, Ch. 27, p. 27)