1、Designation: C 1032 06Standard Specification forWoven Wire Plaster Base1This standard is issued under the fixed designation C 1032; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses

2、indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers woven wire plaster base, flat orself-furring, with or without stiffener wires, and with orwithout backing, designed for use as a

3、base to receive gypsumor portland cement based plaster.1.2 The values stated in inch-pound units are to be regardedas the standard. The SI equivalents of inch-pound units areapproximate.1.3 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and fo

4、otnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2A 641/A 641M Specification for ZincCoated (Galvanized)Carbon Steel WireC11 Terminology Relating to Gypsum and Related Build-ing Materials and Systems2.2 Fe

5、deral Specifications:UU-B-790a Building Paper, Vegetable Fiber: Kraft, Water-proofed, Water Repellent and Fire Resistant3UU-P-31 B/171 Tensile Breaking Strength (Dry)33. Terminology3.1 DefinitionsDefinitions shall be in accordance withTerminology C11.4. Material4.1 In accordance with Specification A

6、 641/A 641M andTable 1.4.2 Kraft Building Paper, Federal Specification UU-B-790a.5. Physical Properties5.1 Backing:5.1.1 Factory attached backing shall provide a one meshwire to wire lap joint at one end and one edge of each flat sheetor roll. Attachment of the backing shall allow lapping ofwire-to-

7、wire and backing-to-backing of one mesh at ends andedges and shall permit full embedment in not less than14 in.(6.4 mm) of plaster of not less than one half the total length andwidth of the wire.5.1.2 Backing shall have a minimum tensile breakingstrength (dry) of 20 lbf/in. (3.5 kN/m) width, as test

8、ed inaccordance with Federal Specification UU-P-31 B,Method 171.6. Dimensions, Weight, and Permissible Variations6.1 Openings:6.1.1 Woven wire plaster base shall be fabricated to providethe size of openings in accordance withTable 1, except that anysingle opening shall be not more than 3.0 in.2(1935

9、.5 mm2).6.1.2 Wire diameter for opening size shall be in accordancewith Table 1.6.2 Diameter tolerance for galvanized wire shall be inaccordance with Specification A 641/A 641M.6.3 The wire shall be zinc-coated (galvanized) in accor-dance with Specification A 641/A 641M.6.4 Weight for woven wire pla

10、ster base shall be in accor-dance with Table 1.6.5 When included as part of the woven wire plaster base,factory fabricated stiffener wires shall have a diameter not lessthan that specified in Table 1 and shall be continuous, parallelto the long dimension of the plaster base, and shall occur at notmo

11、re than 6-in. (154.4-mm) intervals.6.6 Factory fabricated crimps for self-furring woven wireplaster base shall provide a nominal14-in. (6.4-mm) separationbetween the back plane of the plaster base and the surface ofsolid backing to permit embedment in both directions.1This specification is under the

12、 jurisdiction of ASTM Committee C11 onGypsum and Related Building Materials and Systems and is the direct responsibilityof Subcommittee C11.02 on Specifications and Test Methods for Accessories andRelated Products.Current edition approved June 1, 2006. Published June 2006. Originallyapproved in 1985

13、. Last previous edition approved in 2004 as C 1032 04.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Availa

14、ble from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.TABLE 1 Nominal Diameter and Minimum Weightfor Size of OpeningOpening Size,in. (mm)Diameter,in. (mm)Weight,lb/yd2(kg/m2)A1 (25.4) 0.035 (0.89) 0.86 (0.466)112 (38.0) 0.05

15、1 (1.30) 1.40 (0.760)AThe weight of attached backing is not included.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.7 Width of woven wire plaster base shall be not

16、less than36 in. (914 mm).6.8 Length of woven wire plaster base shall be in accor-dance with Table 2.7. Inspection7.1 Inspection of the material shall be agreed upon betweenthe purchaser and the producer or supplier as part of thepurchase agreement.8. Rejection and Rehearing8.1 Material that fails to

17、 conform to the requirements of thisspecification shall be reported to the producer or supplierpromptly and in writing. The notice of rejection shall contain astatement documenting how the product has failed to conformto the requirements of the specification.9. Certification9.1 When specified in the

18、 purchase order or contract, theproducer or supplier shall furnish a report certifying that at thetime of shipment, the materials were in compliance with therequirements of this specification.10. Packaging and Package Marking10.1 PackagingWoven wire plaster base shall be pack-aged in bundles, rolls

19、or pallets.10.2 MarkingWhen shipped for sale or resale, the nameof the producer or the supplier and the brand and description ofthe contents shall be legibly marked on each pallet, bundle orroll. The quantity for bundles shall be square yards and numberof sheet per bundle. The quantity for pallets,

20、bundles or rollsshall indicate the mesh-opening size and wire thickness.11. Keywords11.1 backing; base; cement plaster; flat; gypsum plaster;plaster; self-furning; woven wireSUMMARY OF CHANGESCommittee C11 has identified the location of selected changes to this specification since the last issue,C 1

21、032 04, that may impact the use of this specification. (Approved June 1, 2006)(1) Combined Tables 1 and 2 into new Table 1.(2) Changed references to old Tables 1 and 2 to new Table 1within the text of the specification.(3) Renumbered Table 3 as Table 2.ASTM International takes no position respecting

22、 the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standar

23、d is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International

24、 Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.Thi

25、s standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax),

26、 or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).TABLE 2 Minimum Length of Flat Sheets and RollsAFlat Sheets 100 linear in. (2.540 m)Rolls 150 linear ft. (45.72 m)Rolls, with backing 100 linear ft. (30.48 m)AAllowable variations shall be not more than 34 in. (19.0 mm) in width orlength.C1032062