1、Designation: C155 97 (Reapproved 2013)Standard Classification ofInsulating Firebrick1This standard is issued under the fixed designation C155; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p

2、arentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers heat insulating materialknown as insulating firebrick. This material is suitable forlining certain kinds of industrial

3、furnaces.NOTE 1Insulating materials for use below 1000F (538C) arecovered2by ASTM Committee C-16 on Thermal Insulation.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information on

4、lyand are not considered standard.2. Referenced Documents2.1 ASTM Standards:2C134 Test Methods for Size, Dimensional Measurements,and Bulk Density of Refractory Brick and InsulatingFirebrickC210 Test Method for Reheat Change of Insulating Firebrick3. Significance and Use3.1 This classification estab

5、lishes an orderly grouping ofinsulating firebrick to provide group identifications for use bythose producing or purchasing these materials. The groupidentification number is not meant to specifically designate themaximum service temperature although the number times 100does approximate the temperatu

6、re (in degrees Fahrenheit) to beused to check the reheat change and can be used as a guide forrelative temperature stability. The bulk density limits theweight per unit volume for any group as sold, but is not meantto be used for detailed engineering calculations.4. Basis of Classification4.1 The cl

7、assification of insulating firebrick in accordancewith Table 1 is based on bulk density (weight per cubic foot)and the behavior in the reheat change test conducted at thespecified temperature.5. Test Methods5.1 The properties enumerated in this classification shall bedetermined in accordance with th

8、e following ASTM testmethods:5.1.1 Bulk DensityTest Methods C134.5.1.2 Reheat ChangeTest Method C210. For the purposeof this classification, the percentage of reheat change shall beobtained from only the 9-in. (228-mm) dimension of the testbrick.6. Retests6.1 Because of variables resulting from samp

9、ling and thelack of satisfactory reproducibility in tests conducted bydifferent laboratories, the material may be resampled andretested when requested by either the manufacturer or thepurchaser. This may apply in instances when the first testresults do not conform to the requirements prescribed in t

10、hisclassification. The final results to be used shall be the averageof at least two sets of results, each of which has been obtainedby following in detail the specified testing procedures.7. Keywords7.1 bulk density; insulating firebrick; refractories; reheatchange1This classification is under the j

11、urisdiction of ASTM Committee C08 onRefractories and is the direct responsibility of Subcommittee C08.92 on The JosephE. Kopanda Subcommittee for Editorial, Terminology and Classification.Current edition approved Sept. 1, 2013. Published September 2013. Originallyapproved in 1940. Last previous edit

12、ion approved in 2007 as C155 97 (2007).DOI: 10.1520/C0155-97R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM websi

13、te.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly

14、advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, eit

15、her reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend

16、 If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Ind

17、ividual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured

18、 from the ASTM website (www.astm.org/COPYRIGHT/).TABLE 1 Grouping of Insulating FirebrickGroupNo.Reheat Change, NotMore Than 2 %When Tested atF (C)Bulk DensityNot GreaterThan lb/ft3(g/cm3)16 1550 (845) 34 (0.54)20 1950 (1065) 40 (0.64)23 2250 (1230) 48 (0.77)26 2550 (1400) 54 (0.86)28 2750 (1510) 60 (0.96)30 2950 (1620) 68 (1.09)32 3150 (1730) 95 (1.52)33 3250 (1790) 95 (1.52)C155 97 (2013)2

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1