ASTM C1577-2013b Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers Designed According to AASHTO LRFD《符合美国国家公路与运输协会.pdf

上传人:jobexamine331 文档编号:465185 上传时间:2018-11-27 格式:PDF 页数:22 大小:593.96KB
下载 相关 举报
ASTM C1577-2013b Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers Designed According to AASHTO LRFD《符合美国国家公路与运输协会.pdf_第1页
第1页 / 共22页
ASTM C1577-2013b Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers Designed According to AASHTO LRFD《符合美国国家公路与运输协会.pdf_第2页
第2页 / 共22页
ASTM C1577-2013b Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers Designed According to AASHTO LRFD《符合美国国家公路与运输协会.pdf_第3页
第3页 / 共22页
ASTM C1577-2013b Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers Designed According to AASHTO LRFD《符合美国国家公路与运输协会.pdf_第4页
第4页 / 共22页
ASTM C1577-2013b Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts Storm Drains and Sewers Designed According to AASHTO LRFD《符合美国国家公路与运输协会.pdf_第5页
第5页 / 共22页
亲,该文档总共22页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C1577 13aC1577 13bStandard Specification forPrecast Reinforced Concrete Monolithic Box Sections forCulverts, Storm Drains, and Sewers Designed According toAASHTO LRFD1This standard is issued under the fixed designation C1577; the number immediately following the designation indicates th

2、e year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers single-cell precast rein

3、forced concrete box sections cast monolithically and intended to be used forthe construction of culverts and for the conveyance of storm water, industrial wastes and sewage.NOTE 1This specification is primarily a manufacturing and purchasing specification. However, standard designs per the AASHTO LR

4、FD BridgeDesign Specifications are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this productdepends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specific

5、ations. Thepurchaser of the precast reinforced concrete box sections specified herein is cautioned that proper correlation of the loading conditions and the fieldrequirements with the box section specified, and provision for inspection at the construction site, are required.1.2 The values stated in

6、inch-pound units are to be regarded as standard. No other units of measurement are included in thisstandard.2. Referenced Documents2.1 ASTM Standards:2A1064/A1064M Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for ConcreteA615/A615M Specification for Deformed

7、 and Plain Carbon-Steel Bars for Concrete ReinforcementC33 Specification for Concrete AggregatesC150 Specification for Portland CementC309 Specification for Liquid Membrane-Forming Compounds for Curing ConcreteC497 Test Methods for Concrete Pipe, Manhole Sections, or TileC595 Specification for Blend

8、ed Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and Related ProductsC989 Specification for Slag Cement for Use in Concrete and MortarsC990 Specification for Joints for Concrete Pipe, Manholes,

9、and Precast Box Sections Using Preformed Flexible Joint SealantsC1116 Specification for Fiber-Reinforced Concrete and ShotcreteC1619 Specification for Elastomeric Seals for Joining Concrete StructuresC1677 Specification for Joints for Concrete Box, Using Rubber Gaskets2.2 AASHTO Standards:3AASHTO LR

10、FD Bridge Design SpecificationsAASHTO LRFD Bridge Construction Specifications2.3 ASCE Standard:4ASCE 2697 Standard Practice for Direct Design of Buried Precast Concrete Box Sections1 This specification is under the jurisdiction of ASTM Committee C13 on Concrete Pipe and is the direct responsibility

11、of Subcommittee C13.07 on AcceptanceSpecifications and Precast Concrete Box Sections.Current edition approved July 1, 2013Sept. 1, 2013. Published July 2013September 2013. Originally approved in 2005. Last previous edition approved in 2013 asC1577 13.C1577 13a. DOI: 10.1520/C1577-13A.10.1520/C1577-1

12、3B.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American Association of State Highway and

13、 Transportation Officials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001,http:/www.transportation.org.4 Available from American Society of Civil Engineers (ASCE), 1801 Alexander Bell Dr., Reston, VA 20191, http:/www.asce.org.This document is not an ASTM standard and is intended on

14、ly to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current vers

15、ionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Terminology3.1 DefinitionsFor definitions of terms relating to concrete pipe, see Terminology C822.4.

16、 Designation4.1 Precast reinforced concrete box sections manufactured in accordance with this specification shall be legibly marked withthe specification designation, span, rise, and design earth cover.TABLE 1 Design Requirements for Precast Concrete Box Sections Under Earth, Dead and HL-93 Live Loa

17、d ConditionsNOTE 1Design earth loads and reinforcement areas are based on the weight of a column of earth over the width of the box section multiplied by asoil structure interaction factor as defined in Appendix X1.NOTE 2Concrete design strength 5000 psi.NOTE 3Steel areas are based on an HL-93 live

18、load without the lane load as permitted byAASHTO, using either the design truck or the design tandemand taking the controlling case.NOTE 4The design earth cover indicated is the height of fill above the top of the box section. Design requirements are based on the material and soilproperties, loading

19、 data, and typical section as included in Appendix X1. For alternative or special designs, see 7.2.NOTE 5Design steel area in square inches per linear foot of box section at those locations which are indicated on the typical section shown in Fig. 1.NOTE 6The top section designation, for example, 3 f

20、t by 2 ft by 4 in. indicates (interior horizontal span in feet) by (interior vertical rise in feet) by(wall and slab thickness in inches).NOTE 7In accordance with the acceptance criteria in 7.2, the manufacturer is not prohibited from interpolating steel area requirements or submittingindependent de

21、signs for fill heights between noted increments.NOTE 8The “M” dimension given in the tables is the required distance that As1 shall be extended into the top and bottom slabs if it is used asreinforcement for the negative moment in these areas. This distance is based on the location where the negativ

22、e moment in the slab becomes zero, plusan additional development length. Because the live load can be applied at any location along the top slab as the truck drives over it, it is possible forthe “M” dimension to exceed one-half the length of the slab.NOTE 9(Advisory)The reinforcing areas are based

23、on 4 inch circumferential wire spacing. Under design conditions where crack control governs,an analysis following the design criteria in Table X1.1 with closer steel spacing may result in a reduction in steel area over those in the table.3 ft by 2 ft by 4 in.DesignEarthCover, ftCircumferential Reinf

24、orcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.17 0.25 0.16 0.10 0.17 0.17 0.17 0.1423 0.13 0.19 0.18 0.10 313-5 0.10 0.11 0.12 0.10 3110 0.10 0.10 0.10 0.10 3115 0.10 0.13 0.13 0.10 3120 0.11 0.17 0.17 0.10 3125 0.14 0.21 0.21 0.10 3130 0.17 0.25 0.25 0.10 3135 0.20 0.29 0.30

25、0.10 31A Top slab 7 in., bottom slab 6 in.3 ft by 3 ft by 4 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.17 0.27 0.17 0.10 0.17 0.17 0.17 0.1423 0.10 0.22 0.21 0.10 313-5 0.10 0.14 0.14 0.10 3110 0.10 0.11 0.11 0.10 3115 0.10 0.14 0

26、.15 0.10 3120 0.10 0.18 0.19 0.10 3125 0.10 0.23 0.23 0.10 3130 0.12 0.27 0.28 0.10 3135 0.14 0.32 0.32 0.10 31A Top slab 7 in., bottom slab 6 in.4 ft by 2 ft by 5 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.18 0.27 0.15 0.12 0.18

27、0.18 0.18 0.1423 0.18 0.19 0.17 0.12 383-5 0.13 0.13 0.13 0.12 3810 0.12 0.12 0.12 0.12 3815 0.14 0.16 0.16 0.12 3820 0.18 0.20 0.21 0.12 38C1577 13b225 0.23 0.25 0.25 0.12 3830 0.28 0.30 0.30 0.12 38A Top slab 7.5 in., bottom slab 6 in.C1577 13b34 ft by 3 ft by 5 in.DesignEarthCover, ftCircumferent

28、ial Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.18 0.31 0.18 0.12 0.18 0.18 0.18 0.1423 0.15 0.23 0.20 0.12 383-5 0.12 0.16 0.16 0.12 3810 0.12 0.14 0.14 0.12 3815 0.12 0.18 0.18 0.12 3820 0.14 0.23 0.24 0.12 3825 0.17 0.29 0.29 0.12 3830 0.21 0.35 0.35 0.12 38A Top sla

29、b 7.5 in., bottom slab 6 in.4 ft by 4 ft by 5 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.18 0.33 0.20 0.12 0.18 0.18 0.18 0.1423 0.12 0.26 0.23 0.12 383-5 0.12 0.18 0.18 0.12 3810 0.12 0.15 0.15 0.12 3815 0.12 0.19 0.20 0.12 3820

30、0.12 0.25 0.25 0.12 3825 0.14 0.31 0.31 0.12 3830 0.17 0.37 0.37 0.12 38A Top slab 7.5 in., bottom slab 6 in.5 ft by 2 ft by 6 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.19 0.27 0.18 0.14 0.19 0.19 0.19 0.1723 0.22 0.20 0.16 0.14

31、443-5 0.16 0.14 0.14 0.14 4410 0.15 0.14 0.14 0.14 3615 0.20 0.18 0.18 0.14 3620 0.26 0.23 0.24 0.14 3625 0.33 0.29 0.29 0.14 3630 0.39 0.34 0.35 0.14 36A Top slab 8 in., bottom slab 7 in.5 ft by 3 ft by 6 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7

32、 As8 “M,” in.02A 0.19 0.31 0.21 0.14 0.19 0.19 0.19 0.1723 0.18 0.24 0.19 0.14 453-5 0.14 0.17 0.16 0.14 3610 0.14 0.16 0.17 0.14 3615 0.16 0.21 0.22 0.14 3520 0.21 0.27 0.28 0.14 3525 0.26 0.34 0.34 0.14 3530 0.31 0.41 0.41 0.14 35A Top slab 8 in., bottom slab 7 in.5 ft by 4 ft by 6 in.DesignEarthC

33、over, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.19 0.33 0.24 0.14 0.19 0.19 0.19 0.1723 0.16 0.27 0.22 0.14 453-5 0.14 0.19 0.18 0.14 4510 0.14 0.18 0.18 0.14 3615 0.14 0.23 0.24 0.14 3520 0.17 0.30 0.31 0.14 3525 0.21 0.37 0.38 0.14 3530 0.25 0.44 0

34、.45 0.14 35A Top slab 8 in., bottom slab 7 in.C1577 13b45 ft by 5 ft by 6 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.19 0.35 0.26 0.14 0.19 0.19 0.19 0.1723 0.14 0.29 0.24 0.14 453-5 0.14 0.21 0.20 0.14 4510 0.14 0.19 0.20 0.14 45

35、15 0.14 0.24 0.25 0.14 3620 0.15 0.31 0.32 0.14 3525 0.18 0.38 0.39 0.14 3530 0.21 0.46 0.47 0.14 35A Top slab 8 in., bottom slab 7 in.6 ft by 2 ft by 7in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.23 0.27 0.19 0.17 0.19 0.19 0.19 0.

36、1723 0.25 0.21 0.17 0.17 433-5 0.20 0.17 0.17 0.17 4310 0.20 0.17 0.17 0.17 3915 0.26 0.20 0.20 0.17 3920 0.34 0.26 0.26 0.17 3925 0.43 0.32 0.32 0.17 3930 0.52 0.38 0.39 0.17 39A Top slab 8 in.6 ft by 3 ft by 7 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 A

37、s6 As7 As8 “M,” in.02A 0.20 0.31 0.22 0.17 0.19 0.19 0.19 0.1723 0.21 0.24 0.19 0.17 433-5 0.17 0.18 0.17 0.17 3910 0.17 0.18 0.19 0.17 3915 0.22 0.24 0.24 0.17 3820 0.28 0.31 0.31 0.17 3825 0.35 0.38 0.39 0.17 3830 0.42 0.46 0.46 0.17 38A Top slab 8 in.6 ft by 4 ft by 7 in.DesignEarthCover, ftCircu

38、mferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.19 0.34 0.25 0.17 0.19 0.19 0.19 0.1723 0.19 0.27 0.21 0.17 433-5 0.17 0.21 0.19 0.17 3910 0.17 0.20 0.21 0.17 3915 0.18 0.27 0.27 0.17 3820 0.24 0.34 0.35 0.17 3825 0.29 0.43 0.42 0.17 3830 0.35 0.51 0.52 0.17 38A

39、Top slab 8 in.6 ft by 5 ft by 7 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.19 0.37 0.28 0.17 0.19 0.19 0.19 0.1723 0.17 0.30 0.24 0.17 433-5 0.17 0.23 0.21 0.17 4310 0.17 0.22 0.23 0.17 3915 0.17 0.28 0.29 0.17 3820 0.20 0.37 0.38

40、 0.17 3825 0.25 0.45 0.46 0.17 3830 0.30 0.54 0.55 0.17 38A Top slab 8 in.6 ft by 6 ft by 7 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02A 0.19 0.38 0.30 0.17 0.19 0.19 0.19 0.1723 0.17 0.32 0.26 0.17 523-5 0.17 0.24 0.22 0.17 5210 0.17

41、 0.23 0.24 0.17 43C1577 13b515 0.17 0.29 0.31 0.17 3920 0.18 0.38 0.39 0.17 3925 0.23 0.46 0.48 0.17 3830 0.27 0.55 0.57 0.17 38A Top slab 8 in.7 ft by 2 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02 0.27 0.28 0.19 0.19 0.19 0.1

42、9 0.19 0.1923 0.31 0.21 0.20 0.19 583-5 0.23 0.19 0.19 0.19 4710 0.25 0.19 0.19 0.19 4715 0.33 0.22 0.22 0.19 4320 0.43 0.28 0.29 0.19 4325 0.54 0.35 0.35 0.19 4330 0.65 0.42 0.42 0.19 437 ft by 3 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7

43、As8 “M,” in.02 0.23 0.31 0.22 0.19 0.19 0.19 0.19 0.1923 0.27 0.25 0.24 0.19 473-5 0.19 0.19 0.19 0.19 4310 0.21 0.20 0.21 0.19 4315 0.28 0.26 0.27 0.19 4320 0.36 0.34 0.35 0.19 4325 0.45 0.42 0.43 0.19 4330 0.54 0.50 0.51 0.19 437 ft by 4 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement

44、 Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02 0.21 0.34 0.25 0.19 0.19 0.19 0.19 0.1923 0.23 0.28 0.28 0.19 433-5 0.19 0.22 0.19 0.19 4310 0.19 0.23 0.23 0.19 4315 0.24 0.30 0.30 0.19 4120 0.31 0.38 0.39 0.19 4125 0.38 0.47 0.48 0.19 4130 0.46 0.57 0.57 0.19 417 ft by 5 ft by 8 in.Design

45、EarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02 0.19 0.36 0.27 0.19 0.19 0.19 0.19 0.1923 0.21 0.31 0.31 0.19 473-5 0.19 0.24 0.21 0.19 4310 0.19 0.25 0.26 0.19 4315 0.21 0.32 0.33 0.19 4120 0.27 0.41 0.42 0.19 4125 0.33 0.51 0.52 0.19 4130 0.40 0

46、.61 0.62 0.19 417 ft by 6 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02 0.19 0.38 0.30 0.19 0.19 0.19 0.19 0.1923 0.19 0.33 0.34 0.19 593-5 0.19 0.25 0.23 0.19 4710 0.19 0.26 0.27 0.19 4315 0.19 0.34 0.35 0.19 4120 0.24 0.43 0.4

47、5 0.19 4125 0.29 0.53 0.55 0.19 4130 0.35 0.64 0.65 0.19 417 ft by 7 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02 0.19 0.40 0.33 0.19 0.19 0.19 0.19 0.1923 0.19 0.36 0.37 0.19 593-5 0.19 0.27 0.25 0.19 5910 0.19 0.27 0.29 0.19

48、4715 0.19 0.35 0.37 0.19 43C1577 13b620 0.22 0.44 0.46 0.19 4325 0.27 0.54 0.57 0.19 4330 0.32 0.65 0.67 0.19 418 ft by 2 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02 0.35 0.31 0.21 0.19 0.19 0.19 0.19 0.1923 0.40 0.25 0.23 0.1

49、9 643-5 0.32 0.20 0.20 0.19 5510 0.34 0.21 0.22 0.19 5015 0.45 0.28 0.28 0.19 5020 0.59 0.36 0.37 0.19 5025 0.74 0.45 0.45 0.19 508 ft by 3 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 As8 “M,” in.02 0.31 0.35 0.25 0.19 0.19 0.19 0.19 0.1923 0.35 0.29 0.28 0.19 553-5 0.28 0.23 0.24 0.19 5010 0.29 0.25 0.26 0.19 4515 0.39 0.33 0.34 0.19 4520 0.51 0.43 0.44 0.19 4525 0.63 0.53 0.54 0.19 458 ft by 4 ft by 8 in.DesignEarthCover, ftCircumferential Reinforcement Areas, in.2/ftAs1 As2 As3 As4 As5 As6 As7 A