ASTM D1500-2007 Standard Test Method for ASTM Color of Petroleum Products (ASTM Color Scale)《石油产品ASTM颜色的标准试验方法(ASTM色标)》.pdf

上传人:inwarn120 文档编号:509910 上传时间:2018-12-01 格式:PDF 页数:5 大小:88.79KB
下载 相关 举报
ASTM D1500-2007 Standard Test Method for ASTM Color of Petroleum Products (ASTM Color Scale)《石油产品ASTM颜色的标准试验方法(ASTM色标)》.pdf_第1页
第1页 / 共5页
ASTM D1500-2007 Standard Test Method for ASTM Color of Petroleum Products (ASTM Color Scale)《石油产品ASTM颜色的标准试验方法(ASTM色标)》.pdf_第2页
第2页 / 共5页
ASTM D1500-2007 Standard Test Method for ASTM Color of Petroleum Products (ASTM Color Scale)《石油产品ASTM颜色的标准试验方法(ASTM色标)》.pdf_第3页
第3页 / 共5页
ASTM D1500-2007 Standard Test Method for ASTM Color of Petroleum Products (ASTM Color Scale)《石油产品ASTM颜色的标准试验方法(ASTM色标)》.pdf_第4页
第4页 / 共5页
ASTM D1500-2007 Standard Test Method for ASTM Color of Petroleum Products (ASTM Color Scale)《石油产品ASTM颜色的标准试验方法(ASTM色标)》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 1500 07Designation: 196/97An American National StandardStandard Test Method forASTM Color of Petroleum Products (ASTM Color Scale)1This standard is issued under the fixed designation D 1500; the number immediately following the designation indicates the year oforiginal adoption or, in

2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1

3、This test method covers the visual determination of thecolor of a wide variety of petroleum products, such aslubricating oils, heating oils, diesel fuel oils, and petroleumwaxes.NOTE 1Test Method D 156 is applicable to refined products that havean ASTM color lighter than 0.5. IP Method 17 includes a

4、 procedure formeasuring the color of undyed, refined products such as gasoline, whitespirit, and kerosine by comparison with a series of IP Standard glasses. Italso includes a procedure by which petroleum products, except black oilsand bitumens, may be measured for tint and depth of color in terms o

5、fLovibond units by a series of red, yellow, and blue glasses.1.2 This test method reports results specific to the testmethod and recorded as “ASTM Color.”1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of t

6、his standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 156 Test Method for Saybolt Color of Petroleum Prod-ucts (Saybolt Chromometer Method)D 938 Test Method for Congealin

7、g Point of PetroleumWaxes, Including PetrolatumD 2500 Test Method for Cloud Point of Petroleum ProductsD 4057 Practice for Manual Sampling of Petroleum andPetroleum Products2.2 Energy Institute Standard:3IP 17 Color by the Lovibond Tintometer3. Summary of Test Method3.1 Using a standard light source

8、, a liquid sample is placedin the test container and compared with colored glass disksranging in value from 0.5 to 8.0. When an exact match is notfound and the sample color falls between two standard colors,the higher of the two colors is reported.4. Significance and Use4.1 Determination of the colo

9、r of petroleum products is usedmainly for manufacturing control purposes and is an importantquality characteristic, since color is readily observed by theuser of the product. In some cases, the color may serve as anindication of the degree of refinement of the material. When thecolor range of a part

10、icular product is known, a variation outsidethe established range may indicate possible contamination withanother product. However, color is not always a reliable guideto product quality and should not be used indiscriminately inproduct specifications.5. Apparatus5.1 Colorimeter, consisting of light

11、 source, glass colorstandards, sample container housing with cover, and viewingpiece as listed in Annex A1.5.2 Sample ContainerFor referee work, use the glasssample jar as shown in Fig. 1. For routine tests, it is permissibleto use a cylindrical, clear glass jar with a flat bottom of 30 to32.4 mm in

12、ternal diameter, 115 to 125 mm in external height,and a wall thickness no greater than 1.6 mm as specified in TestMethod D 2500, or an ordinary 125-mL oil sample bottle if itmeets these requirements.6. Sampling6.1 Samples shall be taken in accordance with the instruc-tions in Practice D 4057.1This t

13、est method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved Dec. 1, 2007. Published January 2008. Originallyapproved in 1957.

14、Last previous edition approved in 2004 as D 150004a.This is also a standard of Energy Institute issued under the fixed designation IP196. The final number indicates the year of last revision. This test method wasadopted as a jointASTM-IP standard in 1966. In the IP, this test method is under thejuri

15、sdiction of the Standardization Committee.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3“Methods for Analy

16、sis and Testing,” available from Energy Institute, 61 NewCavendish St., London, WIG 7AR, U.K.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Copyright by ASTM Intl (al

17、l rights reserved); Mon Mar 10 23:08:25 EST 2008Downloaded/printed byGuo Dehua (CNIS) pursuant to License Agreement. No further reproductions authorized.7. Diluent7.1 Solvent Kerosine(WarningCombustible. Vaporharmful.) Having a color lighter than +21 Saybolt color by TestMethod D 156 or 1.5 by Metho

18、d B of IP 17, this material isused for diluting dark samples for the test. As an alternative,other solvents, such as white oil or solvent neutral 100 ofsatisfactory purity that meet the color requirements specifiedhere in 7.1, are also acceptable.NOTE 2Solvent kerosine complies with this requirement

19、 if it is lighterin color than potassium dichromate (K2Cr2O7) solution formed bydissolving 4.8 mg of pure anhydrous K2Cr2O7in 1 L of distilled water.8. Preparation of Sample8.1 Liquid Petroleum Products such as Lubricating OilsFill the sample container to a depth of 50 mm or more andobserve the colo

20、r. When the sample is not clear, heat it justsufficiently enough to make it clear to perform the colormeasurement at that temperature. A sample heated to a tem-perature of 6C (10F) above its cloud point (see Test MethodD 2500) has been found suitable to test samples using this testmethod. When the s

21、ample is darker than 8 color, one mayeither stop the test and report “D8 ASTM Color” (see 10.2)orcontinue the test and mix 15 volumes of sample into 85volumes of solvent kerosine or alternative material (see 7.1)and observe the color of the mixture.8.2 Petroleum Waxes, Including PetrolatumHeat thesa

22、mple just sufficiently enough to make it fluid and clear toperform the color measurement at that temperature withoutheating the wax excessively, because oxidation can occur,along with consequent discoloration of the test specimen. Asample heated to a temperature of 11 to 17C (20 to 30F)above its con

23、gealing point, as determined in accordance withTest Method D 938, has been found suitable to test samplesusing this test method. When the sample is darker than 8 color,one may either stop the test and report “D8 ASTM Color” (see10.2) or continue the test and mix 15 volumes of melted samplewith 85 vo

24、lumes of solvent kerosine or alternative material (see7.1) brought to the same temperature and test the mixture atthat temperature.9. Procedure9.1 Place a sample container or containers, filled to a depthof at least 50 mm with distilled or deionized water, in thecompartment or compartments of the co

25、lorimeter throughwhich the standard glasses will be observed. Place the samplein its container in the other compartment. (When using athree-field comparator, this will be the middle compartment.)Cover the containers to exclude all exterior light.9.2 Switch on the light source and compare the color o

26、f thesample with that of the standard glasses. When using athree-field comparator, the sample must be bracketed by darkerand lighter discs or by an exact match and a darker disc.Determine for two-field comparators which glass matches thecolor of the sample; or if an exact match is not possible, then

27、use that glass which possesses the next darker color.10. Report10.1 Report as the color of the sample, the designation ofthe glass producing a matching color (for example; “7.5ASTMColor.”)10.2 If the color of the sample is intermediate between thoseof two standard glasses, report that the sample is

28、less than thedarker glass designation.As an example, report the designationof the darker glass preceded by the letter “L” (for example,“L7.5ASTM Color”) or with a “8 ASTM Color.”)10.2.1 If the color of the sample is less than the 0.5 glasscolor standard, report that the sample is less than the 0.5 g

29、lasscolor standard. As an example, report the designation as “L0.5ASTM Color” or “0.5 ASTM Color.”10.3 If the sample has been diluted in accordance with 7.1,report the color of the mixture followed by the abbreviation“Dil” (for example, “L7.5 Dil ASTM Color” or “7.5 DilASTM Color”). See Note 3.NOTE

30、3For samples that are diluted in 10.3, it is permissible for thelaboratory to annotate the report in any suitable manner, provided that theinformation clearly conveys to the data recipient that the sample analyzedwas diluted.11. Precision and Bias411.1 PrecisionThe precision of this test method as o

31、b-tained by statistical examination of interlaboratory test resultsis as follows:11.1.1 RepeatabilityThe difference between successivetest results obtained by the same operator with the sameapparatus under constant operating conditions on identical testmaterial would, in the long run, in the normal

32、and correctoperation of the test method, exceed the following value onlyin one case in twenty: 0.5 color units.11.1.2 ReproducibilityThe difference between two singleand independent test results obtained by different operatorsworking in different laboratories on identical test material4Supporting da

33、ta have been filed at ASTM International Headquarters and maybe obtained by requesting Research Report RR: D02-1234.FIG. 1 Standard Glass Sample JarD1500072Copyright by ASTM Intl (all rights reserved); Mon Mar 10 23:08:25 EST 2008Downloaded/printed byGuo Dehua (CNIS) pursuant to License Agreement. N

34、o further reproductions authorized.would, in the long run, in the normal and correct operation ofthe test method exceed the following value only in one case intwenty: 1 color unit.11.2 BiasThe procedure in this test method has no biasbecause the value ofASTM Color is subjective and can only bedefine

35、d in terms of this test method.12. Keywords12.1 ASTM Color; color; petroleum productsANNEX(Mandatory Information)A1. DESCRIPTION OF COLORIMETER AND ASSOCIATED APPARATUSA1.1 ColorimeterUse an instrument that will illuminateand permit observation of the sample and any one of the colorstandards (or in

36、the case of a three-field instrument, any two ofthe color standards) simultaneously, either by direct viewing orwith an optical eyepiece.A1.1.1 A two-field instrument must show two illuminatedareas of equal size and shape, one filled with light transmittedby color standard, the other with light tran

37、smitted by thesample. These illuminated areas shall be disposed symmetri-cally about a vertical median line and shall be separated in ahorizontal direction so that the horizontal separation of theclosest portions subtends the eye of the observer not less than2 nor more than 3.6.A1.1.2 Athree-field i

38、nstrument shall show three illuminatedareas in the field of view. Two areas shall be filled with lighttransmitted by two different color standards, and these shall bedisposed symmetrically about the third area which shall befilled with light transmitted by the sample. The rectangulardimensions of ea

39、ch of the three areas shall be the same, and theleft- and right-hand corners of the full field of view shall berounded with radius not exceeding half the vertical dimension.The illuminated areas shall be separated in a horizontaldirection by vertical lines so that the closest portion of thesample ar

40、ea and any one of the color standards illuminatedareas subtends the eye of the observer not less than 0.3 normore than 0.6.A1.1.3 Each illuminated area in the two-field instrumentshall cover a circle of diameter subtending at least 2.2 andmay be enlarged to any size provided that no two illuminatedp

41、oints in the field of view are separated by a distancesubtending more than 10. In the case of the three-field directviewing instrument, the subtending angles become 2.6 and6.4, respectively.A1.1.4 The angle subtended by a line of length d, in a planeperpendicular to the line of sight, and separated

42、from the eye ofthe observer by a distance D, is given in degrees by 57.3 d/D.The angle subtended by the image of this line, seen by viewingit through an eyepiece of magnification M, is given in degreesby 57.3 Md/Di, where Diis the distance between the eye of theobserver and the plane of the image.A1

43、.2 Artificial Daylight SourceThis may be a separateunit or an integral part of the colorimeter where the combinedsystem of a source lamp (A1.2.1), daylight filter glass (A1.3),and flashed opal glass (A1.2.2) are capable of producingspectral characteristics similar to northern daylight (that is,color

44、 temperature of 6700 6 300 K) for use in the test.NOTE A1.1When electric current is not available, the colorimetermay be designed to use diffused daylight provided that direct sunlight isavoided. Colored objects should be excluded from the immediate fore-ground when using diffused daylight.A1.2.1 So

45、urce LampConsisting of a lamp of color tem-perature of approximately 2750 K (or if a quartz halogen lampis used, approximately 2900 K). A source lamp providing atranslucent or opaque diffuse background of 900 6 100 lxbrightness against which the color standards and samples areviewed has been found s

46、atisfactory to produce the necessaryspectral characteristics. The source lamp shall be designed sothat there is no extraneous light interfering with the observa-tion.A1.2.2 Flashed Opal GlassThe background of illumi-nated opal glass shall be free from glare or shadows.A1.3 FilterAn acceptable daylig

47、ht filter, which has beenused in combination with the artificial daylight source andflashed opal glass to produce the spectral characteristics similarto northern daylight, is one where a spectrometric test indicatesa transmittance of radiant energy of not less than 0.60 at 410nm with a smooth curve

48、down to a transmittance below 0.10 at700 nm without the pronounced bump that is characteristic ofexcess cobalt having an increased transmittance at 570 nmabove a straight line drawn between the points indicatingtransmittance at 540 and 590 nm, and also a transmittance bandabove 660 nm. The transmitt

49、ance of an acceptable filter shallnot, at 570 nm, exceed by more than 0.03 that indicated by astraight line drawn between the points indicating transmittanceat 540 and 590 nm, nor shall the transmittance for 700 nmexceed that for any shorter wavelength (such as 660 nm) bymore than 0.03.TABLE A1.1 Filter CharacteristicsCharacteristicLamp Color Temperature, K2750 3300T 0.107 to 0.160 0.075 to 0.125x 0.314 to 0.330 0.300 to 0.316y 0.337 to 0.341 0.325 to 0.329z 0.329 to 0.349 0.355 to 0.375D1500073Copyright by ASTM Intl (all rights reserved); Mon Mar 10 2

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1