ASTM D3418-2012 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度和熔化焓.pdf

上传人:diecharacter305 文档编号:514743 上传时间:2018-12-02 格式:PDF 页数:7 大小:114.79KB
下载 相关 举报
ASTM D3418-2012 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度和熔化焓.pdf_第1页
第1页 / 共7页
ASTM D3418-2012 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度和熔化焓.pdf_第2页
第2页 / 共7页
ASTM D3418-2012 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度和熔化焓.pdf_第3页
第3页 / 共7页
ASTM D3418-2012 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度和熔化焓.pdf_第4页
第4页 / 共7页
ASTM D3418-2012 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度和熔化焓.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D3418 12Standard Test Method forTransition Temperatures and Enthalpies of Fusion andCrystallization of Polymers by Differential ScanningCalorimetry1This standard is issued under the fixed designation D3418; the number immediately following the designation indicates the year oforiginal a

2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.

3、1. Scope*1.1 This test method covers determination of transitiontemperatures and enthalpies of fusion and crystallization ofpolymers by differential scanning calorimetry.NOTE 1True heats of fusion are to be determined in conjunction withstructure investigation, and frequently, specialized crystalliz

4、ation tech-niques are needed.1.2 This test method is applicable to polymers in granularform or to any fabricated shape from which it is possible to cutappropriate specimens.1.3 The normal operating temperature range is from thecryogenic region to 600C. Certain equipment allows thetemperature range t

5、o be extended.1.4 The values stated in SI units are the standard.NOTE 2This test method does not apply to all types of polymers aswritten (see 6.8).1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this st

6、andard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 3This standard is similar but not equivalent to ISO 11357-1, -2,-3. The ISO procedures provide additional information not supplied bythis test method.2. Reference

7、d Documents2.1 ASTM Standards:2E473 Terminology Relating to Thermal Analysis and Rhe-ologyE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE967 Test Method for Temperature Calibration of Differen-tial Scanning Calorimeters and Differential Thermal Ana-l

8、yzersE968 Practice for Heat Flow Calibration of DifferentialScanning CalorimetersE1142 Terminology Relating to Thermophysical PropertiesE1953 Practice for Description of Thermal Analysis andRheology Apparatus2.2 ISO Standards:3ISO 11357-1 PlasticsDifferential Scanning Calorimetry(DSC)Part 1: General

9、 PrinciplesISO 11357-2 PlasticsDifferential Scanning Calorimetry(DSC)Part 2: Determination of Glass Transition Tem-peratureISO 11357-3 PlasticsDifferential Scanning Calorimetry(DSC)Part 3: Determination of Temperature and En-thalpy of Melting and Crystallization3. Terminology3.1 Specialized terms us

10、ed in this test method are defined inTerminologies E473 and E1142.4. Summary of Test Method4.1 This test method consists of heating or cooling the testmaterial at a controlled rate under a specified purge gas at acontrolled flow rate and continuously monitoring with asuitable sensing device the diff

11、erence in heat input between areference material and a test material due to energy changes inthe material. A transition is marked by absorption or release ofenergy by the specimen resulting in a corresponding endother-mic or exothermic peak or baseline shift in the heating orcooling curve. Areas und

12、er the crystallization exotherm orfusion endotherm of the test materials are compared against therespective areas obtained by the treatment of a well-characterized standard.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D

13、20.30 on Thermal Properties(Section D20.30.07).Current edition approved Aug. 1, 2012. Published September 2012. Originallyapproved in 1975. Last previous edition approved in 2008 as D3418 - 08. DOI:10.1520/D3418-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM

14、Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.*A Summary of Chang

15、es section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 Thermal analysis provides a rapid method for measuringtransitions due to morphological or chemical changes, in ap

16、olymer as it is heated/cooled through a specified temperaturerange. Change in specific heat capacity, heat flow and tempera-ture values are determined for these transitions. Differentialscanning calorimetry is used to assist in identifying specificpolymers, polymer alloys, and certain polymer additi

17、ves,which exhibit thermal transitions. Chemical reactions thatcause or affect certain transitions have been measured with theaid of this technique; such reactions include oxidation, curingof thermosetting resins, and thermal decomposition.5.2 This test method is useful for specification acceptance,p

18、rocess control, and research.6. Interferences6.1 Differences in heating or cooling rate as well as the finalheating and cooling temperature have an effect on the mea-sured results, especially on the enthalpy of fusion or crystalli-zation. Therefore, departure from conditions specified for agiven pol

19、ymer is not permitted.6.2 The presence of impurities is known to affect thetransition temperature, particularly if an impurity tends to formsolid solutions, or to be miscible in the melt phase.6.3 Uncertain radiation losses at temperatures higher than400C have been known to affect the accuracy of re

20、sults attimes.6.4 Since particle size has an effect upon detected transitiontemperatures, the specimens to be compared shall be approxi-mately the same particle size (1-5).46.5 In cases that specimens react with air during thetemperature cycle, provision shall be made for running the testunder an in

21、ert gas blanket to avoid any incorrect measurement.Since some materials degrade near the melting region, caremust be used to distinguish between degradation and transition.6.6 Since milligram quantities of a specimen are used, it isessential to ensure that specimens are homogeneous andrepresentative

22、.6.7 It is possible that toxic or corrosive effluents are releasedwhen heating the material, and be harmful to the personnel orto the apparatus.6.8 Not all polymers lend themselves to the exact terms ofthis test method. For some polymers such as polyarylamides,crystallization is only possible from s

23、olution. For other poly-mers such as crystallizable polystyrene, annealing is onlypossible above their glass transition temperatures. When thistest method is used for polymers of this type, carefullyannealed samples must be tested without conditioning.7. Apparatus7.1 Differential Scanning Calorimete

24、r (DSC)The essentialinstrumentation required to provide the minimum differentialscanning calorimetric capability for this test method includes:7.1.1 DSC Test ChamberThis chamber is composed of thefollowing:7.1.1.1 Furnace(s), to provide uniform controlled heating(cooling) of a specimen and reference

25、 to a constant temperatureor at a constant rate within the applicable cryogenic to 600Ctemperature range of this test method.7.1.1.2 Temperature Sensor, to provide an indication of thespecimen temperature to 60.01C.7.1.1.3 Differential Sensor, to detect heat flow differencebetween the specimen and r

26、eference equivalent to 1 mW.7.1.1.4 Means of Sustaining a Test Chamber Environment ofpurge gas at a purge flow rate of 10 to 50 6 5 mL/min.NOTE 4Typically, 99+ % pure nitrogen, argon or helium are employedwhen oxidation in air is a concern. Unless effects of moisture are to bestudied, use of dry pur

27、ge gas is recommended and is essential foroperation at sub-ambient temperatures.7.1.2 Temperature Controller, Temperature Controller, ca-pable of executing a specific temperature program by operatingthe furnace(s) between selected temperature limits at a rate oftemperature change of 0.5 to 20C/min c

28、onstant to 60.1C/min or at an isothermal temperature constant to 60.1C.7.1.3 Recording Device, capable of recording and display-ing any fraction of the heat flow signal (DSC curve) includingthe signal noise as a function of temperature.7.1.4 Software, for integrating areas under endothermicvalleys o

29、r exothermic peaks, or both.7.1.5 Containers (pans, crucibles, and so forth) that are inertto the specimen and reference materials; and that are of suitablestructural shape and integrity to contain the specimen andreference in accordance with the specific requirements of thistest method.7.1.6 Coolin

30、g capability to hasten cool down from elevatedtemperatures, to provide constant cooling rates of 0.5 - 20C/min to obtain repeatable crystallization temperatures, toachieve sub-ambient operation, or to sustain an isothermalsub-ambient temperature, or combination thereof.7.2 Balance, capable of weighi

31、ng to 60.0001 grams fortransition temperatures and to 60.00001 grams for determin-ing enthalpies.8. Sample8.1 Powdered or Granular SpecimensAvoid grinding ifthe preliminary thermal cycle as outlined in 10.1.3 is notperformed. Grinding or similar techniques for size reductionoften introduce thermal e

32、ffects because of friction ororientation, or both, and thereby change the thermal history ofthe specimen.8.2 Molded or Pelleted SpecimensCut the specimens witha microtome, razor blade, hypodermic punch, paper punch, orcork borer (Size No. 2 or 3) or other appropriate means toappropriate size, in thi

33、ckness or diameter and length that willbest fit the specimen containers as in 7.1.5 and will approxi-mately meet the desired weight in the subsequent procedure.8.3 Film or Sheet SpecimensFor films thicker than 40 m,see 8.2. For thinner films, cut slivers to fit in the specimencapsules or punch disks

34、, if the circular specimen capsules areused.4The boldface numbers in parentheses refer to the list of references at the end ofthis test method.D3418 1228.4 Use any shape or form listed in 8.1-8.3 except whenconducting referee tests that shall be performed on films asspecified in 8.3.9. Calibration9.

35、1 The purge gas shall be used during calibration.9.2 Calibrate the DSC temperature signal using PracticeE967 and the same heating rate to be used in this test methodpreferably 10C/min or 20C/min (see Note 5). (See Section 10for details.)9.3 Calibrate the DSC heat flow signal using Practice E968and t

36、he same heating rate as in 9.2 (see Note 5).9.4 Some instruments allow for the temperature and heatflow calibration to be performed simultaneously. In such cases,use the same heating rate for this method and follow themanufacturers instruction. Report the heating rate. (See12.1.3.)NOTE 5Use of other

37、 heating rates is permitted. However, test resultsare affected by the heating rate. It is the responsibility of the user of otherrates to demonstrate equivalency to this test method.10. Procedure10.1 For First-Order Transition (melting and crystalliza-tion):10.1.1 The purge gas shall be used during

38、testing. The flowrate of the gas shall be the same as used in the calibration (9.1).10.1.2 Use a specimen mass appropriate for the material tobe tested. In most cases a 5-mg specimen mass is satisfactory.Avoid overloading. Weigh the specimen to an accuracy of 610g.10.1.2.1 Intimate thermal contact b

39、etween the pan andspecimen is essential for reproducible results. Crimp a metalcover against the pan with the sample sandwiched in betweento ensure good heat transfer. Take care to ensure flat panbottoms.10.1.3 Perform and record a preliminary thermal cycle byheating the sample at the same rate used

40、 for testing from atleast 50C below to 30C above the melting temperature toerase previous thermal history.10.1.4 When the effect of annealing is studied, selection oftemperature and time are critical. Minimize the time ofexposure to high temperature to avoid sublimation or decom-position. In some ca

41、ses it is possible that the preliminarythermal cycle will interfere with the transition of interest,causing an incorrect transition or eliminating a transition.Where it has been shown that this effect is present, omit thepreliminary thermal cycle.10.1.5 Hold the temperature for 5 min (10.1.3).NOTE 6

42、In cases that high-temperature annealing cause polymerdegradation, the use of shorter annealing times is permitted but shall bereported.10.1.6 Cool to at least 50C below the peak crystallizationtemperature using the same rate that was used for heating andrecord the cooling curve.10.1.7 Hold the temp

43、erature for 5 min.10.1.8 Repeat heating at the same rate used in 10.1.3(10C/min or 20C/min) and record the heating curve. Use thiscurve to calculate the enthalpies of transition.10.1.9 Measure the temperatures for the desired points onthe curves: Teim,Tpm,Tefm,Teic,Tpc, and Teic(see Fig. 1).Report t

44、wo Tpms or Tpcs if observed.10.1.10 In case of dispute determine Tmand Tcat a heatingrate of 10C/min.where:Teim= melting extrapolated onset temperature, C,Tefm= melting extrapolated end temperature, C,Tpm= melting peak temperature, C,Teic= crystallization extrapolated onset temperature, C,Tpc= cryst

45、allization peak temperature, C, andTefc= crystallization extrapolated end temperature, C.NOTE 7The actual temperature displayed on the temperature axisdepends upon the instrument type (for example, specimen temperature,program temperature, or specimen-program temperature average). Followany recommen

46、ded procedures or guidelines of the instrument manufac-turer to obtain specimen temperature at the point of interest.10.2 For Glass Transition:10.2.1 The purge gas shall be used during testing. The flowrate of the gas shall be the same as used in the calibration (9.1).10.2.2 Use a specimen mass appr

47、opriate for the material tobe tested. In most cases, a 10-mg specimen mass is satisfactory.Weigh the specimen to an accuracy of 610 g.10.2.3 Perform and record a preliminary thermal cycle byheating the sample at a rate of 20C/min from at least 50Cbelow to 30C above the melting temperature to erase p

48、reviousthermal history.10.2.4 Hold the temperature for 5 min. (See Note 6.)10.2.5 Quench cool to at least 50C below the transitiontemperature of interest.10.2.6 Hold the temperature for 5 min.10.2.7 Repeat heating at a rate of 20C/min, and record theheating curve until all desired transitions have b

49、een completed.(See Note 5.)10.2.8 The glass transition is more pronounced at fasterheating rates. A heating rate of 20C/min is the preferredheating rate for Tgmeasurements. The instrument shall becalibrated at the same heating rate used for testing. If both first-and second-order transitions (Tmand Tg, respectively) are to bedetermined in the same run, use the same heating rate as usedin 10.1.8 for both transitions and determine results from thesecond heating step (10.1.8). Report the heating rate. (See12.1.3.)NOTE 8Tgobtained usin

展开阅读全文
相关资源
猜你喜欢
  • ANSI E1.19-2009 Recommended Practice for the Use of Class A Ground-Fault Circuit Interrupters (GFCIs) Intended for Personnel Protection in the Entertainment Industry《娱乐业中用于个人保护的A类接.pdf ANSI E1.19-2009 Recommended Practice for the Use of Class A Ground-Fault Circuit Interrupters (GFCIs) Intended for Personnel Protection in the Entertainment Industry《娱乐业中用于个人保护的A类接.pdf
  • ANSI E1.20-2010 Entertainment Technology - Remote Device Management over USITT DMX512《娱乐技术.包括DMX512 网络作业的遥控设备管理》.pdf ANSI E1.20-2010 Entertainment Technology - Remote Device Management over USITT DMX512《娱乐技术.包括DMX512 网络作业的遥控设备管理》.pdf
  • ANSI E1.22-2009 Entertainment Technology - Fire Safety Curtain Systems《娱乐技术.火灾安全幕帘系统》.pdf ANSI E1.22-2009 Entertainment Technology - Fire Safety Curtain Systems《娱乐技术.火灾安全幕帘系统》.pdf
  • ANSI E1.23-2010 Entertainment Technology - Design and Execution of Theatrical Fog Effects《娱乐业技术.舞台背景雾效果设计和管理》.pdf ANSI E1.23-2010 Entertainment Technology - Design and Execution of Theatrical Fog Effects《娱乐业技术.舞台背景雾效果设计和管理》.pdf
  • ANSI E1.26-2006 Entertainment Technology - Recommended Testing Methods and Values for Shock Absorption of Floors Used in Live Performance Venues《娱乐业技术.现场表演舞台地板减震数值的推荐试验方法》.pdf ANSI E1.26-2006 Entertainment Technology - Recommended Testing Methods and Values for Shock Absorption of Floors Used in Live Performance Venues《娱乐业技术.现场表演舞台地板减震数值的推荐试验方法》.pdf
  • ANSI E1.27-1-2006 Entertainment Technology - Standard for Portable Control Cables for use with ANSI E1.11 (DMX512-A) and USITT DMX512 1990 Products《娱乐业技术.用于ANSI E1.11 (DMX512-A)和US.pdf ANSI E1.27-1-2006 Entertainment Technology - Standard for Portable Control Cables for use with ANSI E1.11 (DMX512-A) and USITT DMX512 1990 Products《娱乐业技术.用于ANSI E1.11 (DMX512-A)和US.pdf
  • ANSI E1.27-2-2009 Entertainment Technology - Recommended Practice for Permanently Installed Control Cables for Use with ANSI E1.11 (DMX512-A) and USITT DMX512 1990 Products《娱乐业技术.A.pdf ANSI E1.27-2-2009 Entertainment Technology - Recommended Practice for Permanently Installed Control Cables for Use with ANSI E1.11 (DMX512-A) and USITT DMX512 1990 Products《娱乐业技术.A.pdf
  • ANSI E1.29-2009 Product Safety Standard for Theatrical Fog Generators that Create Aerosols of Water Aqueous Solutions of Glycol or Glycerin or Aerosols of Highly Refined Alkane Min.pdf ANSI E1.29-2009 Product Safety Standard for Theatrical Fog Generators that Create Aerosols of Water Aqueous Solutions of Glycol or Glycerin or Aerosols of Highly Refined Alkane Min.pdf
  • ANSI E1.3-2001 Entertainment Technology - Lighting Control Systems - 0 to 10V Analog Control Specification《娱乐技术.照明控制系统.0至10V模拟控制规范》.pdf ANSI E1.3-2001 Entertainment Technology - Lighting Control Systems - 0 to 10V Analog Control Specification《娱乐技术.照明控制系统.0至10V模拟控制规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1