ASTM D5289-2017 Standard Test Method for Rubber Property&x2014 Vulcanization Using Rotorless Cure Meters《用无转子硫化仪测量橡胶性能硫化的标准试验方法》.pdf

上传人:visitstep340 文档编号:519384 上传时间:2018-12-03 格式:PDF 页数:9 大小:293.98KB
下载 相关 举报
ASTM D5289-2017 Standard Test Method for Rubber Property&x2014 Vulcanization Using Rotorless Cure Meters《用无转子硫化仪测量橡胶性能硫化的标准试验方法》.pdf_第1页
第1页 / 共9页
ASTM D5289-2017 Standard Test Method for Rubber Property&x2014 Vulcanization Using Rotorless Cure Meters《用无转子硫化仪测量橡胶性能硫化的标准试验方法》.pdf_第2页
第2页 / 共9页
ASTM D5289-2017 Standard Test Method for Rubber Property&x2014 Vulcanization Using Rotorless Cure Meters《用无转子硫化仪测量橡胶性能硫化的标准试验方法》.pdf_第3页
第3页 / 共9页
ASTM D5289-2017 Standard Test Method for Rubber Property&x2014 Vulcanization Using Rotorless Cure Meters《用无转子硫化仪测量橡胶性能硫化的标准试验方法》.pdf_第4页
第4页 / 共9页
ASTM D5289-2017 Standard Test Method for Rubber Property&x2014 Vulcanization Using Rotorless Cure Meters《用无转子硫化仪测量橡胶性能硫化的标准试验方法》.pdf_第5页
第5页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D5289 17Standard Test Method forRubber PropertyVulcanization Using Rotorless CureMeters1This standard is issued under the fixed designation D5289; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi

2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a method for the measurementof selected vulcanization characteristics of rubber compoundsusing unsealed a

3、nd sealed torsion shear cure meters. The twotypes of instruments may not give the same results.NOTE 1An alternative method for the measurement of vulcanizationcharacteristics is given in Test Method D2084.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parent

4、heses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regul

5、atory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Or

6、ganization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1349 Practice for RubberStandard Conditions for Test-ingD1566 Terminology Relating to RubberD2084 Test Method for Rubber PropertyVulcanizationUsing Oscillating Disk Cure MeterD4483 Practice for Evaluati

7、ng Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustries3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 rotorless cure meter, na name for a class of curemeters that uses one of the two specimen shaping members ordies to sense the torque or s

8、tress during strain application.Rotorless cure meters do not have a third member in the formof a rotor (see definitions of cure meter in Terminology D1566and Test Method D2084).3.1.2 S torque, nfor an oscillating shear rotorless curemeter, the value measured by a torque transducer at the peakstrain

9、amplitude of the oscillating cycle; represents the elasticresponse of the test material.3.1.3 The following measurements may be taken from therecorded curve of torque as a function of time (see Fig. 1):3.1.3.1 minimum S torquemeasure of the elastic stiffnessof the unvulcanized test specimen at the s

10、pecified vulcanizingtemperature, taken at the lowest point in the vulcanizationcurve.3.1.3.2 maximum, plateau, or highest S torquemeasure ofthe elastic stiffness of the vulcanized test specimen at thespecified vulcanizing temperature, measured within a specifiedperiod of time.3.1.3.3 time to a perce

11、ntage of full curemeasure of curebased on the time to develop some percentage of the differencein S torque from the minimum to the maximum.3.1.3.4 time to incipient cure (scorch time)measure of thetime at which a specified small increase in S torque hasoccurred; it indicates the beginning of vulcani

12、zation.3.1.4 S” torque, nfor an oscillating shear rotorless curemeter, the value measured by a torque transducer at zero strainamplitude of the oscillating cycle; represents the viscousresponse of the test material (see Fig. 2).3.1.5 S* torque, nfor an oscillating shear rotorless curemeter, the maxi

13、mum value measured by a torque transducerduring the oscillating cycle (see Fig. 2).3.1.6 The relationship between S*, S, and S” for anyoscillating cycle is:S* 5 =S !21S ”!2(1)1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand Rubber-like Materials and is the direct respon

14、sibility of Subcommittee D11.12on Processability Tests.Current edition approved Oct. 1, 2017. Published November 2017. Originallyapproved in 1992. Last previous edition approved in 2012 as D5289 12. DOI:10.1520/D5289-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact

15、ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard

16、was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.1.7 phas

17、e angle , nfor an oscillating shear cure meter,the angle of shift between the sinusoidal strain and thesinusoidal S* torque during the oscillating cycle (see Fig. 2).3.1.8 Tan , nfor an oscillating shear rotorless cure meter,the tangent of the phase angle .3.1.8.1 DiscussionThe relationship between

18、Tan , S, andS” is:Tan 5S ”S (2)FIG. 1 Typical Vulcanization CurvesFIG. 2 Example of Torque Responses for an Oscillation CycleD5289 1723.1.9 The following measurements may be taken from therecorded S” and Tan curves as a function of time (see Fig. 1):3.1.9.1 S” MLvalue of S” torque when the minimum S

19、torque is taken.3.1.9.2 Tan MLvalue of Tan when the minimum Storque is measured.3.1.9.3 S” MHvalue of S” torque when the maximumS torque is taken.3.1.9.4 Tan MHvalue of Tan when the maximum Storque is measured.4. Summary of Test Method4.1 A rubber test piece is contained in a die cavity whichmay be

20、closed or almost closed and maintained at an elevatedtemperature. The cavity is formed by two dies, one of which isoscillated through a small rotary amplitude. This action pro-duces a sinusoidal alternating torsional strain in the test pieceand a sinusoidal shear torque which depends on the stiffnes

21、s(shear modulus) of the rubber compound.4.2 The stiffness of the rubber test piece increases asvulcanization proceeds. The test is completed when the re-corded torque rises to either an equilibrium or maximum value,or when a predetermined time has elapsed (see Fig. 1).Acurverepresenting the torque a

22、t peak strain in one direction of theoscillation cycle is continuously recorded as a function of time.5. Significance and Use5.1 This test method is used to determine the vulcanizationcharacteristics of (vulcanizable) rubber compounds.5.2 This test method may be used for quality control inrubber man

23、ufacturing processes, for research and developmenttesting of raw-rubber compounded in an evaluationformulation, and for evaluating various raw materials used inpreparing (vulcanizable) rubber compounds.5.3 The test specimen in a rotorless cure meter approachesthe test temperature in a shorter time a

24、nd there is a bettertemperature distribution in the test specimen due to theelimination of the unheated rotor found in oscillating disk curemeters.5.4 Several manufacturers produce rotorless cure meterswith design differences that may result in different torqueresponses and cure times for each desig

25、n. Correlations of testresults between cure meters of different designs should beestablished for each compound tested, and for each set of testconditions.6. Apparatus6.1 Rotorless cure meters of two types can be used. In eachcase, an oscillation of small amplitude is applied to one die.6.1.1 Unseale

26、d Torsion Strain Rotorless Cure MeterThistype of cure meter measures the torque produced by an angularstrain of constant amplitude in a cavity that is not completelyclosed (see Fig. 3(a).6.1.2 Sealed Torsion Strain Rotorless Cure MeterThistype of cure meter measures the torque produced by an angular

27、strain of constant amplitude in a cavity that is completelyclosed and sealed (see Fig. 4(a).6.2 Die CavityThe die cavity is formed by two dies. In themeasuring position, the two dies are fixed a specified distanceapart so that the cavity is almost closed (see Fig. 3(b), orclosed and sealed (see Fig.

28、 4(a).6.2.1 The dimensions for typical torsional shear curemetersinclude biconical-shaped dies having a diameter of 40 6 2mm(1.57 6 0.08 in.), and an angle of separation ranging from 7 to18, depending on the manufacturers design. In the center ofthe dies, a separation equal to 0.5 mm (0.02 in.) plus

29、 the diegap should be maintained (see Fig. 3(b) or Fig. 4(b). Manu-facturers guidelines should be followed to determine if thedies have been excessively worn and should be replaced.6.2.2 Die GapThe gap between the edges of the dies in theclosed position shall be between 0.05 and 0.20 mm (0.002 to0.0

30、08 in.), preferably 0.1 mm (0.004 in.) for unsealed cavities.For sealed cavities, no gap should exist at the edges of the dies.6.2.3 Die Closing MechanismA pneumatic cylinder orother device shall close the dies and hold them closed duringthe test with a force of not less than 8.0 kN (1820 lbf).6.3 D

31、ie Oscillating SystemThe die oscillating systemimparts a torsional oscillating movement to one of the dies, inthe plane of the cavity.6.3.1 The amplitude of the oscillation should be 60.1 to63.0, preferably 60.5 of arc for torsional shear cure meters.6.3.2 The frequency of oscillation should be betw

32、een 0.5and 2 Hz, preferably 1.7 6 0.1 Hz.6.4 Torque Measuring SystemA torque measuring systemshall measure the resultant torque.6.4.1 The torque measuring device shall be rigidly coupledto one of the dies and any deformation shall be negligibly smalland shall generate a signal which is proportional

33、to the torque.The total error resulting from zero point error, sensitivity error,linearity, and reproducibility errors shall not exceed 1 % of themeasuring range selected.NOTE 2The elastic deformation of the oscillating and measuringsystem should not be more than 1 % of the oscillating amplitude;oth

34、erwise, the curemeter curves must be corrected.6.4.2 The torque recorder device shall be used to record thesignal from the torque measuring device. It shall record the Storque at maximum oscillation as a function of time.6.4.3 The torque recorder device shall be used to record thesignal from the tor

35、que measuring device. It shall record thetorque at maximum oscillation continuously as a function oftime (see Fig. 1) and shall have a response time for full-scaledeflection on the torque scale of1sorless. The torque shall berecorded with an accuracy of 60.5 % of the range. Torquerecording devices m

36、ay include analog chart recorders, printers,plotters, or computers.6.5 Torque calibration equipment is required to measure theangular strain amplitude and to calibrate the torque measuringdevice. Examples of calibration equipment are shown in Fig. 5and Fig. 6. The amplitude of oscillation of the dev

37、ice shall bechecked with no test specimen in it. A displacement transducershall be used to measure the amplitude and torque measure-ments shall be checked against standard masses using a deviceas shown in Fig. 5. An alternate technique shall use a torquestandard.D5289 1736.5.1 For calibrating torsio

38、n shear curemeters, either adisplacement transducer and wire-mass calibration or a torquestandard shall be used.6.5.1.1 A displacement transducer for checking angulardisplacement shall be coupled by a knife-edge bearing incontact with a rod fixed to one of the dies (see Fig. 5). TheFIG. 3 (a) and (b

39、)Typical Unsealed Torsion Shear Rotorless CuremeterD5289 174force measuring system shall be checked by loading a wire,attached to the die or block by a pulley, with masses corre-sponding to the full-scale force being measured. The torqueshall be calculated in this case from the product of the applie

40、dforce and the radius of the die block where the wire is attached.6.5.1.2 Torque standard calibration checks the torque mea-surement at the selected angular displacement by clamping areference steel torsion rod to the oscillating die and the torquemeasuring die of the torsion shear cure meter (see F

41、ig. 6). Thereference values for angular displacement and correspondingtorque have been established by the manufacturer for eachtorque standard.6.6 Temperature Controlling SystemThe method of tem-perature control shall maintain the following process param-eters: heating up time, curing temperature, t

42、emperaturedistribution, and reference temperature, which are necessaryfor reproducible measurement of the vulcanization curve. Thetemperature control system shall permit the reference tempera-ture to be varied between 110C and 200C with an accuracyof 60.3C or better.6.6.1 Die shall heat up in 1.5 mi

43、n or less from closure of thedie cavity.6.6.2 Once heating up time hs been completed, die tempera-ture shall not vary by more than 60.3C for the rest of the test.6.6.3 The temperature distribution within the test specimenshall be as uniform as possible. Within the deformation zone,a tolerance of 61C

44、 of the average test specimen temperatureshall not be exceeded.6.6.4 The reference temperature is determined by a tempera-ture sensor used for control. The difference between thereference temperature and the average test specimen tempera-ture shall not be more than 2C.6.6.5 Temperature measurement a

45、ccuracy shall be60.3C for the reference temperature sensor.FIG. 4 Typical Sealed Torsion Shear Rotorless CuremeterFIG. 5 Displacement Transducer and Wire-Mass CalibrationEquipment for Torsion Shear CuremetersFIG. 6 Typical Torque Standard Calibration Device for TorsionShear CuremetersD5289 1756.7 Re

46、ference Test TemperatureThe standard referencetest temperature shall be 160C (320F). Tests may be carriedout at other temperatures if required. Temperatures should beselected in accordance with Practice D1349.7. Sampling7.1 The sample shall be taken from a vulcanizable rubbercompound as required by

47、the mixing method or other samplinginstructions.7.2 The sample shall be homogeneous, in sheeted form, atroom temperature, and as free of air as possible.7.3 The temperature of the sample and its heat history cansignificantly affect test results. For referee testing and fortesting under controlled ci

48、rcumstances, the sample shall beconditions at 23 6 1C (73 6 2F) for at least 1 h beforetesting.7.4 In production control testing, samples may be testedwithout the conditioning period, but care should be taken tominimize temperature and heat history variations prior totesting.8. Test Specimen8.1 The

49、recommended test specimen volume is between 3and6cm3, depending on the instrument model being used.8.2 The test specimen should be circular, with a diametersmaller than the test chamber of the instrument to be used.8.3 The test specimen is considered to be of proper sizewhen a small bead of rubber compound is extruded uniformlyaround the periphery of the dies as they are closed (116 to160 % of the test cavity volume). For an instrument with a testcavity volume of 3.44 cm3, this is achieved w