ASTM D5346-1993(2009) Standard Test Method for Determination of the Pour Point of Petroleum Oil Used in Fatliquors and Softening Compounds《测定油乳液和软化化合物用石油润滑油倾点的标准试验方法》.pdf

上传人:arrownail386 文档编号:519536 上传时间:2018-12-03 格式:PDF 页数:3 大小:79.26KB
下载 相关 举报
ASTM D5346-1993(2009) Standard Test Method for Determination of the Pour Point of Petroleum Oil Used in Fatliquors and Softening Compounds《测定油乳液和软化化合物用石油润滑油倾点的标准试验方法》.pdf_第1页
第1页 / 共3页
ASTM D5346-1993(2009) Standard Test Method for Determination of the Pour Point of Petroleum Oil Used in Fatliquors and Softening Compounds《测定油乳液和软化化合物用石油润滑油倾点的标准试验方法》.pdf_第2页
第2页 / 共3页
ASTM D5346-1993(2009) Standard Test Method for Determination of the Pour Point of Petroleum Oil Used in Fatliquors and Softening Compounds《测定油乳液和软化化合物用石油润滑油倾点的标准试验方法》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 5346 93 (Reapproved 2009)Standard Test Method forDetermination of the Pour Point of Petroleum Oil Used inFatliquors and Softening Compounds1This standard is issued under the fixed designation D 5346; the number immediately following the designation indicates the year oforiginal adopti

2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the pourpoint of petroleum oi

3、ls used in the softening and stuffing ofleather, and in the manufacture of fatliquors and other soften-ing and stuffing compounds.This test method was derived fromTest Method D97and ALCA Method H-18.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are in

4、cluded in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior

5、 to use.2. Referenced Documents2.1 ASTM Standards:2D97 Test Method for Pour Point of Petroleum ProductsE1 Specification for ASTM Liquid-in-Glass Thermometers2.2 Other Document:ALCA Method H-18 Cloud and Pour Point33. Significance and Use3.1 This test method is intended to determine the pour pointof

6、petroleum oils used in the softening and stuffing of leather,as well as those used in the manufacture of products for suchpurpose. The pour point of petroleum oils is measured for thepurpose of quality assurance.4. Apparatus (see Fig. 1)4.1 Test Jar, clear cylindrical glass, flat bottom, 30 to33.5-m

7、m inside diameter, and 115 to 125-mm height. Toindicate sample height the jar should be marked with a line 546 3 mm above the inside bottom.4.2 Thermometers, having ranges shown below and con-forming to the requirements prescribed in Specification E1forthermometers:Temperature Thermometer NumberTher

8、mometer Range ASTM IPHigh cloud and pour 38 to +50C 5C 1CLow cloud and pour 80 to +20C 6C 2CMelting point +32 to +127C 61C 63C4.2.1 Since separation of liquid column thermometers occa-sionally occurs and may escape detection, thermometersshould be checked immediately prior to the test and used onlyi

9、f they prove accurate within 6 1C (for example ice point).4.3 Cork, to fit the test jar, bored centrally for the testthermometer.4.4 Jacket, metal or glass, watertight, cylindrical, flat bot-tom, 115 mm in depth, 42 to 50 mm inside diameter. It must besupported firmly in a vertical position in the c

10、ooling bath of 4.7so that not more than 25 mm projects out of the coolingmedium.4.5 Disk, cork or felt, 6 mm thick to fit loosely inside thejacket.4.6 Gasket, to fit snugly around the outside of the test jarand loosely inside the jacket. The gasket may be made ofrubber, leather, or other material th

11、at is elastic enough to clingto the test jar and hard enough to hold its shape. Its purpose isto prevent the test jar from touching the jacket.4.7 Bath or Baths, maintained at prescribed temperatureswith a firm support to hold the jacket vertical. The requiredbath temperatures may be obtained by ref

12、rigeration if avail-able, otherwise by suitable freezing mixtures. Freezing mix-tures commonly used for temperatures down to those shownare as follows:For Temperatures DownIce and water 9CCrushed ice and sodium chloride crystals 12CCrushed ice and calcium chloride crystals 27CAcetone or petroleum na

13、phtha (see Section 5) chilledin a covered metal beaker with an ice-salt mixtureto 12C then with enough solid carbon dioxide togive the desired temperature.57CNOTE 1There are automatic pour point testers available and in usewhich may be advantageous in the saving of test time, permit the use of1This

14、test method is under the jurisdiction ofASTM Committee D31 on Leatherand is the direct responsibility of Subcommittee D31.08 on Fats and Oils.Current edition approved April 1, 2009. Published July 2009. Originallyapproved in 1993. Last previous edition approved in 2003 as D 5346 93 (2003)e1.2For ref

15、erenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Leather Chemists Assn., Texas Tech Universit

16、y, P.O.Box 45300, Lubbock, TX 794091Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.smaller samples, and have other factors which may merit their use. Ifautomatic testers are used, the user must ensure that all of the manufac-turers i

17、nstructions for calibration, adjustment and operation of theinstrument are followed. It must be reported that the pour point wasdetermined by an automatic instrument. Precision of automatic pour pointtesters has not been determined. In any case of dispute, the pour point asdetermined by the manual m

18、ethod described herein shall be considered thereference test.5. Reagents and Materials5.1 The following solvents of technical grade are appropri-ate for low-temperature bath media.5.1.1 Acetone.(WarningExtremely flammable.)5.1.2 Alcohol, Ethanol.(WarningFlammable.)5.1.3 Alcohol, Methanol.(WarningFla

19、mmable. Vaporharmful.)5.1.4 Petroleum Naphtha.(WarningCombustible. Vaporharmful.)5.1.5 Solid Carbon Dioxide.(WarningExtremelycold 78.5C.)6. Procedure6.1 Pour the oil into the test jar to the level mark. Whennecessary, heat the oil in a water bath until it is just sufficientlyfluid to pour into the t

20、est jar.NOTE 2When it is known that a sample has been heated to atemperature higher than 45C during the preceding 24 h or when thethermal history of the sample is not known, keep the sample at roomtemperature for 24 h before testing it.6.2 Close the test jar with the cork carrying the high-pourtherm

21、ometer (4.2). In the case of pour points above 36C, usea higher range thermometer such as IP 3C or ASTM 61C.Adjust the position of the cork and thermometer so the cork fitstightly, the thermometer and the jar are coaxial, and thethermometer bulb is immersed so the beginning of the capillaryis 3 mm b

22、elow the surface of the oil.6.3 For the measurement of pour point, subject the oil in thetest jar to the following preliminary treatment:6.3.1 Oils Having Pour Points Above 33CHeat the oilwithout stirring to 9C above the expected pour point, but to atleast 45C, in a bath maintained at 12C above the

23、expectedpour point, but at least 48C. Transfer the test jar to a waterbath maintained at 24C and commence observations for pourpoint.6.3.2 Oils Having Pour Points of 33C and BelowHeatthe oil without stirring to 45C in a bath maintained at 48Cand cool to 15C in a water bath maintained at 6C. Removeth

24、e high cloud and pour thermometer and place the low cloudand pour thermometer in position.NOTE 1Dimensions are in millimetres.FIG. 1 Apparatus for Pour Point TestD 5346 93 (2009)26.4 See that the disk, gasket, and the inside of the jacket areclean and dry. Place the disk in the bottom of the jacket.

25、 Placethe gasket around the test jar, 25 mm from the bottom. Insertthe test jar in the jacket. Never place a jar directly into thecooling medium.6.5 After the oil has cooled to allow the formation ofparaffin wax crystals, take great care not to disturb the mass ofoil nor permit the thermometer to sh

26、ift in the oil; anydisturbance of the spongy network of wax crystals will lead tolow and erroneous results.6.6 Pour points are expressed in integers that are positive ornegative multiples of 3C. Begin to examine the appearance ofthe oil when the temperature of the oil is 9C above theexpected pour po

27、int (estimated as a multiple of 3C). At eachtest thermometer reading that is a multiple of 3C below thestarting temperature, remove the test jar from the jacket. Toremove condensed moisture that limits visibility, wipe thesurface with a clean cloth moistened in alcohol (ethanol ormethanol). Tilt the

28、 jar just enough to ascertain whether there isa movement of the oil in the test jar. The complete operation ofremoval, wiping, and replacement shall require not more than3s.6.6.1 If the oil has not ceased to flow when its temperaturehas reached 27C, transfer the test jar to the next lowertemperature

29、 bath per the following schedule:Oil is at +27C, move to 0C bath,Oil is at +9C, move to 18C bath,Oil is at 6C, move to 33C bath,Oil is at 24C, move to 51C bath,Oil is at 42C, move to 69C bath.6.6.2 As soon as the oil in the jar does not flow when tilted,hold the jar in a horizontal position for 5 s,

30、 as noted by anaccurate timing device and observe carefully. If the oil showsany movement, replace the test jar immediately in the jacketand repeat a test for flow at the next temperature, 3C lower.6.7 Continue in this manner until a point is reached at whichthe oil shows no movement when the test j

31、ar is held in ahorizontal position for 5 s. Record the observed reading of thetest thermometer.NOTE 3To determine compliance with existing specifications havingpour point limits at temperatures not divisible by 3C, it is acceptablepractice to conduct the pour point measurement according to the follo

32、wingschedule: Begin to examine the appearance of the oil when the tempera-ture of the oil is 9C above the specification pour point. Continueobservations at 3C intervals as described in 6.6 and 6.7 until thespecification temperature is reached. Report the sample as passing orfailing the specification

33、 limit.6.8 For black oil, cylinder stock and nondistillate fuel oil,the result obtained by the procedure described in 6.1-6.7 is theupper (maximum) pour point. If required, determine the lower(minimum) pour point by heating the sample while stirring, to105C, pouring it into the jar, and determining

34、the pour pointas described in 6.4-6.7 .7. Calculation and Report7.1 Add 3C to the temperature recorded in 6.7 and reportthe result as the pour point, ASTM D5346. For black oil, etc.,add 3C to the temperature recorded in 6.7 and report the resultas upper pour point,ASTM D5346, or lower pour point,AST

35、MD5346, as required.8. Precision and Bias8.1 Lubricating Oils and Distillate and Residual Fuel Oil:8.1.1 RepeatabilityThe difference between successive testresults, obtained by the same operator using the same apparatusunder constant operating conditions on identical test material,would in the long

36、run, in the normal and correct operation ofthis test method, exceed 3C only in one case in twenty.Differences greater than this should be considered suspect.8.1.2 ReproducibilityThe difference between two singleand independent test results, obtained by different operatorsworking in different laborat

37、ories on identical test material,would in the long run, in normal and correct operation of thistest method, exceed 6C only in one case in twenty. Differencesgreater than this should be considered suspect.8.2 BiasThere being no criteria for measuring bias inthese test-product combinations, no stateme

38、nt of bias can bemade.8.3 The precision statements were prepared with data on tennew (unused) mineral oil based lubricants and sixteen assortedfuel oils tested by twelve cooperators. The mineral oil basedlubricants had pour points ranged from 48C to 6C whilethe fuel oils had pour points ranging from

39、 33C to + 51C.The following precision data were obtained:95 % Confidence Mineral Oil Lubricants Fuel OilsRepeatability, CReproducibility, C2.876.432.526.599. Keywords9.1 fatliquors; leather; petroleum oil pour point; softeningand stuffing compoundsASTM International takes no position respecting the

40、validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is

41、subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Head

42、quarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This sta

43、ndard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D 5346 93 (2009)3

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1