ASTM E1390-2012 Standard Specification for Illuminators Used for Viewing Industrial Radiographs《观察工业X光照片用照明装置的标准规范》.pdf

上传人:livefirmly316 文档编号:528599 上传时间:2018-12-05 格式:PDF 页数:3 大小:83.37KB
下载 相关 举报
ASTM E1390-2012 Standard Specification for Illuminators Used for Viewing Industrial Radiographs《观察工业X光照片用照明装置的标准规范》.pdf_第1页
第1页 / 共3页
ASTM E1390-2012 Standard Specification for Illuminators Used for Viewing Industrial Radiographs《观察工业X光照片用照明装置的标准规范》.pdf_第2页
第2页 / 共3页
ASTM E1390-2012 Standard Specification for Illuminators Used for Viewing Industrial Radiographs《观察工业X光照片用照明装置的标准规范》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: E1390 12Standard Specification forIlluminators Used for Viewing Industrial Radiographs1This standard is issued under the fixed designation E1390; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio

2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 The function of the illuminator is to provide sufficientillumination and viewing capabilities for the purpose of iden-tification

3、and interpretation of radiographic images. This speci-fication provides the recommended minimum requirements forIndustrial Radiographic Illuminators used for viewing indus-trial radiographic films using transmitted light sources.1.2 The illuminator has to ensure the same safety forpersonnel, or user

4、s of any electric apparatus, as specified byelectrical standards applicable in the country in which theilluminator is used.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro

5、-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 Values stated in SI units are to be regarded as thestandard. The values given in parentheses are provided forinformation only.2. Referenced Documents2.1 ASTM Standards:2E1316 Terminology f

6、or Nondestructive Examinations3. Terminology3.1 Definitions:3.1.1 diffusing screenthe screen that scatters the light suchthat the light appears the same brightness from any viewingangle.3.1.2 viewing screenthe port through which the light isprojected.3.2 For additional definitions of terms used in t

7、his specifi-cation, see Terminology E1316.4. Ordering Information4.1 This specification is intended to be used by the manu-facturers and purchasers of radiographic illuminators. Require-ments, if imposed on manufacturers, should be established bycontractual agreement or appropriate purchase document

8、.5. Materials and Manufacture5.1 GeneralThe illuminator shall consist of a housingwith one or more of the sides containing a viewing screenilluminated from the inside of the housing. The viewing screenmay also be the diffusing screen. There shall be thermalprotection to prevent overheating, and subs

9、equent damage tothe radiographs placed on the viewing screen. The housing orsystem may or may not require ventilation. A rheostat orsuitable electrical circuit shall be provided to vary the lightintensity.6. Physical Properties6.1 GeneralThe illuminator shall be manufactured ofmaterials deemed suita

10、ble to withstand the environmentalconditions encountered under normal operating conditions.6.2 Viewing ScreenThe viewing screen shall be easy toclean and made of material which is resistant to scratches. Thesize of the screen shall allow the user to view the radiographwithout excessive glare. If the

11、 illuminator is to be used forviewing radiographs of various sizes, masks of various sizesand configurations should be provided. Alternately, an adjust-able aperture may be used.1This specification is under the jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibil

12、ity of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved June 15, 2012. Published July 2012. Originallyapproved in 1990. Last previous edition approved in 2006 as E1390 - 06. DOI:10.1520/E1390-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcont

13、act ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West

14、 Conshohocken, PA 19428-2959, United States.6.3 Color of LightThe color of the light used to illuminatethe radiograph shall be white, that is, color temperaturebetween 5000 and 6250K. However, illuminators using non-white or “colored” light may be used if they have beenrecommended by the film manufa

15、cturers.6.4 Diffusing ScreenIf the illuminator has a diffusingscreen, the light shall be sufficiently divergent in accordancewith 7.2.6.5 HousingThe external housing shall be constructed insuch a manner that no disturbing light hinders the viewing ofthe radiographs.6.6 Anti-Glare DeviceThe illuminat

16、or shall be fitted withan anti-glare switch or device that minimizes the probability ofthe operator being subjected to excessive glare when theradiograph is removed. This switch or device may be manual orautomatic.6.7 Illuminators Used for Viewing “Wet” RadiographsIlluminators manufactured for use i

17、n viewing “wet” radio-graphs shall be manufactured to prevent the penetration ofliquid into internal electrical components in such a manner thatsafe operation of the unit would be compromised.7. Performance Requirements7.1 Maximum Luminance outputThe luminance of thetransmitted light shall not be le

18、ss than 30 candelas per squaremetre for film densities equal to or less than 2.5 optical densityand not less than 10 candelas per square metre for filmdensities greater than 2.5 optical density.7.2 Divergence and Diffusion of LightIf the illuminatorhas a diffusing screen, the light shall be sufficie

19、ntly divergentso that both eyes of the observer receive rays from all parts ofthe screen. The divergence factor shall exceed 0.7.7.3 The viewing screen shall be uniformly illuminated withthe uniformity factor d being higher than 0.5.7.4 Appropriate precautions shall be taken by the manufac-turer to

20、ensure that temperature of the housing does not exceed60C (140F) at the usual contact surfaces after one hour ofoperation at a 50 % duty cycle.7.5 A radiograph having a density of 2.0 optical densitywhen placed onto the illuminator viewing surface shall notwarp or curl after one minute of continuous

21、 viewing time andone hour of operation of the illuminator at a 50 % duty cycle.8. Scope8.1 The following tests shall be utilized to verify theperformance requirements specified in 7.1 through 7.3 of thisspecification.8.1.1 Maximum illuminator luminance shall be determinedusing a calibrated photomete

22、r placed at the center of theviewing surface, and shall be measured in accordance with thedirections specified by the photometers manufacturer.8.1.2 Maximum illuminator luminance measurements are totake place in a room with less than 20 lux (approximately 2footcandles) of background light. Light esc

23、aping from theilluminator even when the viewing screen is completelymasked shall not affect the measurements.8.2 Divergence and Diffusion of LightIf the illuminatorhas a diffusing screen, the light shall be sufficiently divergentso that both eyes of the observer receive rays from all parts ofthe scr

24、een. The divergence factor shall exceed 0.7.8.2.1 The luminance shall be measured on a semi-circle, thecenter of which is center of the screen.8.2.2 The diameter of the circle is approximately the sameas the maximum dimension of the screen (the diagonal). Theradius of this semi-circle should be at l

25、east 25 cm (10 in.).8.2.3 The luminance is measured with the aid of an appro-priate luminance photometer whose sensitive surface is tangentto the curve of the circle (see Fig. 1). These measurements shallbe made at angles of 5 (L5), 20 (L20), and 45 (L45) relativeto the normal (L0) to the diffusing

26、screen. The divergencefactor, s, shall be calculated according to the followingequation:s 5L451 L202 L58.3 The viewing screen shall be uniformly illuminated withthe uniformity factor d being higher than 0.5, and calculated inthe following manner:8.3.1 The measurements shall be made with the aid of a

27、nillumination photometer or other suitable instrument.8.3.2 If the screen is rectangular, it shall be divided intosquares, each side of the squares measuring 3.5 cm, theluminance of each being measured separately. If the screen iscircular, the same basic procedure shall be followed. In bothcases, th

28、e network of the squares shall be so arranged that themiddle square is centered in the middle of the screen.8.3.3 The average of the four highest and the average of thefour lowest results shall be found, which give the averagearithmetical values of the luminance Lmaxand Lmin. Theuniformity factor g

29、shall then be calculated according to theformula:d5LminLmax9. Certification9.1 The manufacturer is responsible for certifying that theilluminator conforms to the requirements of this specificationprior to shipping to customer.FIG. 1 Measurement Angles of Diversion and Dispersion of LightE1390 1229.2

30、 At the request of the customer, the manufacturer of theilluminator shall provide a written statement indicating confor-mance to the requirements of this specification and test resultsif requested.10. Product Marking10.1 Each illuminator will have the following informationpermanently affixed by the

31、manufacturer:10.1.1 Nominal operating voltage or permissible voltagerange.10.1.2 Nominal line frequency or permissible frequencyrange.10.1.3 Whether direct, alternating current, or both may beused.10.1.4 Whether designed for use with “wet” film viewing.10.1.5 Nominal power consumption.10.1.6 Maximum

32、 brightness in candelas per square metre ascalculated during factory acceptance tests.10.1.7 Lamp type.11. Packaging and Package Marking11.1 Each illuminator will be provided with operatinginstructions that address the following:11.1.1 Safety precautions to be expected during the normaloperating con

33、ditions.11.1.2 Operating conditions.11.1.3 Instructions for mounting and replacements of lampsand screens.11.1.4 Care and recommended maintenance procedures.11.1.5 Replacement lamp and screen identification and sup-plier contact information.12. Quality Assurance12.1 The manufacturer is responsible f

34、or testing and certi-fying that the illuminator conforms to the requirements of thisspecification prior to shipping to customer.13. Keywords13.1 illuminator; luminance; radiographSUMMARY OF CHANGESCommittee E07 has identified the location of selected changes to this standard since the last issue (E1

35、390 - 06)that may impact the use of this standard. (June 15, 2012)(1) Added definitions for viewing screen and diffusing screen3.1.1.(2) Added “additional” to last sentence in 3.2.(3) Changed from “masks shall be provided” to “masks shouldbe provided” in 6.2.(4) Changed from “sufficiently divergent

36、so that both eyes ofthe observer receive rays from all parts of the screen” to“sufficiently divergent per the requirements of 8.2” in 6.4.(5) Changed punctuation error at end of sentence in 7.3.(6) Changed brightness to luminance as proper terminology in8.2.1.(7) Changed brightness to luminance as p

37、roper terminology in8.2.3.(8) Added to include lamp type in 10.1.7.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any

38、such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are inv

39、ited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received

40、 a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of th

41、is standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/COPYRIGHT/).E1390 123