ASTM E473-2007a Standard Terminology Relating to Thermal Analysis and Rheology《热分析和流变学相关标准术语》.pdf

上传人:fatcommittee260 文档编号:532840 上传时间:2018-12-06 格式:PDF 页数:3 大小:55.78KB
下载 相关 举报
ASTM E473-2007a Standard Terminology Relating to Thermal Analysis and Rheology《热分析和流变学相关标准术语》.pdf_第1页
第1页 / 共3页
ASTM E473-2007a Standard Terminology Relating to Thermal Analysis and Rheology《热分析和流变学相关标准术语》.pdf_第2页
第2页 / 共3页
ASTM E473-2007a Standard Terminology Relating to Thermal Analysis and Rheology《热分析和流变学相关标准术语》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: E 473 07aStandard Terminology Relating toThermal Analysis and Rheology1This standard is issued under the fixed designation E 473; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p

2、arentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This terminology is a compilation of definitions of termsused in ASTM documents relating to thermal analysis andrheology. This terminology includ

3、es only those terms for whichASTM either has standards or is contemplating some action. Itis not intended to be an all-inclusive listing of terms related tothermal analysis and rheology.1.2 This terminology specifically supports the single-wordform for terms using thermo-as a prefix, such as thermoa

4、na-lytical or thermomagnetometry, while recognizing that forsome terms a two-word form can be used, such as thermalanalysis. This terminology does not support, nor does itrecommend, use of the grammatically incorrect, single-wordform using thermalas a prefix, such as, thermalanalytical orthermalmagn

5、etometry.1.3 Definitions that are similar to those published by anotherstandards body are identified with the abbreviation of the nameof the organization: for example, ICTAC is the InternationalConfederation for Thermal Analysis and Calorimetry.1.4 A definition is a single sentence with additional i

6、nfor-mation included in notes. It is reviewed every five years, andthe year of the last review or revision is appended.2. Terminologycombined, adjthe application of two or more techniques todifferent samples at the same time. (ICTAC) (1999)controlled-rate thermal analysis, (CRTA), na family oftechni

7、ques that monitors the temperature versus time profileneeded to maintain a chosen, fixed rate of change of aproperty of a substance. (ICTAC) (1999)NOTE 1Compared to controlled-temperature experiments, where thereaction rate tends to increase exponentially and the rate can becomelimited by heat or ma

8、ss transfer, CRTA experiments are more likely toinvolve the chemical reaction as the limiting step. This technique can alsoimprove the resolution of multiple reactions. For example, in controlledrate experiments, power to the furnace is controlled to ensure a fixed rateof mass loss (or gain).control

9、led-temperature program, nthe temperature historyexperienced by a sample during the course of a thermalanalysis experiment.NOTE 2In contrast to controlled-rate experiments, power to thefurnace is controlled to ensure a fixed rate of temperature change forcontrolled-temperature experiments. The progr

10、am may include heating orcooling segments in which the temperature is changed at a fixed rate,isothermal segments in which time becomes the explicit independentvariable, or any sequence of these individual segments. If the atmosphere(or vacuum) around the sample is changed by some external action(de

11、pending on the independent variable onlytemperature or time)during the course of the experiment, that too becomes part of thecontrolled-temperature program.curve, thermal, nthe plot of a dependent parameter againstan independent parameter such as temperature or time.(ICTAC) (1999)dielectric thermal

12、analysis, (DETA or DEA), na techniquein which the dielectric constant (permittivity, or capacitance)and dielectric loss (conductance) of a substance underoscillating electric field are measured as a function oftemperature or time while the substance is subjected to acontrolled-temperature program in

13、 a specified atmophere.(ICTAC) (1999)derivative, adjpertaining to the first derivative (mathemati-cal) of any curve with respect to temperature or time.differential, adjpertaining to a difference in measured ormeasureable quantities usually between a substance andsome reference or standard material.

14、differential scanning calorimetry (DSC), nA technique inwhich the heat flow difference into a substance and areference material is measured as a function of temperaturewhile the substance and reference material are subjected to acontrolled-temperature program. (ICTAC) (1999)NOTE 3The record is the d

15、ifferential scanning calorimetric or DSCcurve. Two modes, power compensation differential scanning calorimetry,and heat flux differential scanning calorimetry can be distinguished,depending on the method of measurement used.differential thermal analysis (DTA), nA technique in whichthe temperature di

16、fference between the substance and areference material is measured as a function of temperature,while the substance and reference material are subjected to acontrolled-temperature program. (ICTAC) (1999)NOTE 4The term quantitative differential thermal analysis coversthose uses of DTA where the equip

17、ment is designed to produce quantita-tive results.1This terminology is under the jurisdiction of ASTM Committee E37 onThermal Measurements and are the direct responsibility of Subcommittee E37.03 onNomenclature and Definitions.Current edition approved July 1, 2007. Published July 2007. Originally ap

18、provedin 1973. Last previous edition approved in 2007 as E 473 07.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.dilatometry, nsee Thermodilatometry.dynamic mechanical analysis (DMA), na technique inwhich the storage modulus (elasti

19、c response) and lossmodulus (viscous response) of a substance under oscillatoryload is measured as a function of temperature, time, orfrequency of oscillation, while the substance is subjected toa controlled-temperature program in a specified atmosphere.(ICTAC) (1999)evolved gas analysis (EGA), na t

20、echnique in which thenature and amount, or both, of gas or vapor evolved by asubstance is subjected to a controlled-temperature program.(ICTAC) (1999)NOTE 5Some specific forms of EGA have become established forinvestigating different aspects of catalysis, such as reduction, oxidation ordesorption. I

21、n this context, EGA in a hydrogen atmosphere is known astemperature-programmed reduction (TPR); EGAin an oxygen atmosphereis temperature-programmed oxidation (TPO); and EGA in the absence ofdecomposition, in an inert atmosphere or vaccum, is temperature-programmed desorption (TPD). For each techniqu

22、e the method used forgas identification and quantification should always be clearly stated.evolved gas detection, (EGD), nsee evolved gas analysis.extrapolated onset value, nthe value of the independentparameter found by extrapolating the dependent parameterbaseline prior to the event and a tangent

23、constructed at theinflection point on the leading edge to their intersection.first-deviation-from baseline , nsee onset value.high-pressure, (HP.), adja prefix for different thermoana-lytical techniques in which the pressure in the apparatus isabove ambient. (ICTAC) (1999)NOTE 6As an example, high-p

24、ressure thermogravimetric analysis isdesignated HPTGA.isothermal, adjat constant temperaturemodulated temperature, adja prefix applied to the tech-nique named to indicate that temperature modulation hasbeen applied to the temperature program.NOTE 7As an example, a DSC experiment carried out with amo

25、dulated temperature program would be Modulated Temperature Dif-ferential Scanning Calorimetry (MTDSC).NOTE 8Other modulated techniques are possible, such as modulatedforce TMA.NOTE 9 The use of the prefix MT is preferred to TM.onset point (temperature or time), nthe temperature ortime at which a def

26、lection is first observed from theestablished baseline prior to the thermal event.peak , nthat portion of a thermal curve characterized by adeviation from the established baseline, a maximum depen-dent (ordinate) parameter deflection, and a restablishment ofa baseline not necessarily identical to th

27、at before the peak.E 1445peak value, nthe value of the independent parameter corre-sponding to the maximum (or minimum) deflection from thebaseline of the dependent parameter curve.rheometer, nan instrument for measuring rheological prop-erties with a controlled temperature, shear rate or stressprog

28、ram.rheometry, na technique in which viscosity, storage modu-lus, and loss modulus of a material are measured as afunction of temperature, time, shear rate or stress while thematerial is subjected to controlled temperature, shear rate orstress program.simultaneous, adjthe application of two or more

29、techniquesto the same sample at the same time. (ICTAC) (1999)NOTE 10A hyphen is used to separate the abbreviations of thetechniques; for example, simultaneous thermogravimetric analysis anddifferential scanning calorimetry would be TGA-DSC.stochastic, adjrandom.tan d, nis the dimensionless ratio of

30、energy lost to energyreturned during one cycle of a periodic process. Tan d isnormally calculated by dividing the loss component of theproperty measured by a periodic method by the storagecomponent (for example, tan d= E”/E as used in DMA).thermal analysis (TA) , na group of techniques in which aphy

31、sical property of a substance is measured as a function oftemperature or time while the substance is subjected to acontrolled-temperature program. (ICTAC) (1999)thermally stimulated current analysis, na technique inwhich the current generated when dipoles change theiralignment in a substance is meas

32、ured as a function oftemperature or time while the substance is subjected to acontrolled-temperature program in a specified atmosphere.(ICTAC)NOTE 11The technique can be applied in several ways: for example;the substance can be pre-conditioned by heating and cooling in anonoscillating electric field

33、 to create aligned, frozen dipoles. The sub-stance may then generate a thermally stimulated current during subsequentheating with no field applied.thermoanalytical, adjof, or pertaining to, thermal analysis.(ICTAC) (1980)thermodilatometry, na technique in which a dimension of asubstance under neglig

34、ible load is measured as a function oftemperature while the substance is subjected to a controlled-temperature program in a specified atmosphere. (ICTAC)(1980)NOTE 12Linear thermodilatometry and volume thermodilatometryare distinguished on the basis of the dimension measured.thermogravimetry (TG), n

35、see thermogravimetric analy-sis.thermogravimetric analysis, (TGA), na technique in whichthe mass of a substance is measured as a function oftemperature or time while the substance is subjected to acontrolled-temperature program in a specified atmosphere.(ICTAC) (1999)NOTE 13The record is the thermog

36、ravimetric or TG curve. Thisdefinition is similar to the ICTAC definition of the term thermogravimetry.thermomagnetometry, na family of thermoanalytical tech-niques in which a magnetic characteristic of a substance ismeasureed as a function of temperature or time while thesubstance is subjected to a

37、 controlled-temperature programin a specified atmosphere. (ICTAC)NOTE 14Thermogravimetric analysis with a magnetic field acting onthe specimen is the most common example.thermomechanical analysis, (TMA), na technique in whichE 473 07a2the deformation of a substance under nonoscillatory load ismeasur

38、ed as a function of temperature or time while thesubstance is subjected to a controlled-temperature programin a specified atmosphere. (ICTAC)NOTE 15The load on the substance may be compressive, tensile,flexural or torsional. When the applied load is too low to causedeformation, TMA measures a dimens

39、ion of the substance and in thismode is called thermodilatometry.thermomicroscopy, nsee thermoptometry.thermoptometry, na family of techniques in which anoptical characteristic of a substance is measured as afunction of temperature or time while the substance issubjected to a controlled-temperature

40、program in a specifiedatmosphere. (ICTAC)NOTE 16Measurement of total light, light of specific wavelength(s),refractive index, and luminescence leads, respectively, to thermophotom-etry, thermospectrometry, thermorefractometry, and thermoluminescence.Observations under the microscope lead to thermomi

41、croscopy.torsional braid analysis, (TBA), na particular case ofdynamic mechanical analysis in which the material issupported on a braid and the specimen is examined intorsion. (ICTAC) (1999)viscometer, nan instrument for measuring viscosity at fixedtemperature, shear rate, or stress.viscometry, na t

42、echnique in which viscosity of a material ismeasured at fixed temperature, shear rate or stress.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determin

43、ation of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or wit

44、hdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that yo

45、ur comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).E 473 07a3

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1