1、Designation: F 1861 02Standard Specification forResilient Wall Base1This standard is issued under the fixed designation F 1861; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indi

2、cates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers resilient wall base. Theseproducts are manufactured from rubber or thermoplastic ma-terials, or a combination thereof. Wall base is us

3、ed to providea functional, as well as decorative border, between walls andfloors. This specification does not include rigid products.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 The following safety caveat pe

4、rtains to the test methodsportion, Section 12, of this specification: This standard doesnot purport to address all the safety concerns, if any, associ-ated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applica

5、bility of regulatory limitations priorto use.2. Referenced Documents2.1 The following documents of the issue in effect on thedate of the material purchase form a part of this specification tothe extent referenced herein:2.2 ASTM Standards:D 883 Terminology Relating to Plastics2D 1566 Terminology Rel

6、ating to Rubber3D 1755 Specification for Poly(Vinyl Chloride) Resins2F 137 Test Method for Flexibility of Resilient FlooringMaterials with Cylindrical Mandrel Apparatus4F 141 Terminology Relating to Resilient Floor Coverings3F 386 Test Method for Thickness of Resilient FlooringHaving Flat Surfaces4F

7、 410 Test Method for Wear Layer Thickness of ResilientFloor Coverings by Optical Measurement4F 925 Test Method for Resistance to Chemicals of ResilientFlooring4F 1515 Test Method for Measuring Light Stability of Resil-ient Vinyl Flooring by Color Change42.3 Other Standards:ANSI/ASQC Z1.41993 Samplin

8、g Procedures and Tablesfor Inspection by Attributes53. Terminology3.1 DefinitionsFor definitions of other terms used in thisstandard, see Terminology F 141.4. Classification4.1 TypesWall base shall be of the following types, asspecified (see 5.1.2, 6.1, and 7.1).4.1.1 Type TSrubber, vulcanized therm

9、oset.4.1.2 Type TPrubber, thermoplastic.4.1.3 Type TVvinyl, thermoplastic.4.2 GroupsWall base shall be one of the followinggroups, as specified (see 5.1.2, 6.2.1, and 6.2.2):4.2.1 Group 1solid (homogeneous).4.2.2 Group 2layered (multiple layers).4.2.3 Either group may be specified with any of the ty

10、pesabove. It is not necessary to specify group when either isacceptable.4.3 StylesWall base shall be of the following styles asspecified (see 5.1.2, 6.3, and Fig. 1):4.3.1 Style Astraight.4.3.2 Style Bcove.4.3.3 Style Cbutt-to.4.4 CornersWhere specified, both inside and outside 90factory-made corner

11、s should be specified by style. Cornersmust meet the same height and thickness requirements as wallbase (see Section 9).NOTE 1Factory-made corners and wall base may have visual colordifferences due to process and material variations. Consult the manufac-turer to ensure color acceptability between fa

12、ctory-made corners and wallbase prior to ordering.5. Ordering Information5.1 Purchasers shall state whether this specification is to beused, select the preferred options permitted herein, and includethe following information in the invitation to bid or purchaseorder:5.1.1 Title, number, and date of

13、this specification,5.1.2 Type, group, and style, (see Sections 4, 6, and 7),5.1.3 Factory-made corners, if required (see 4.4),1This specification is under the jurisdiction of ASTM Committee F06 onResilient Floor Coverings and is the direct responsibility of Subcommittee F06.80on Specifications.Curre

14、nt edition approved Sept. 10, 2002. Published November 2002. Originallypublished as F 186198. Last previous edition F 186100.2Annual Book of ASTM Standards, Vol 08.01.3Annual Book of ASTM Standards, Vol 09.01.4Annual Book of ASTM Standards, Vol 15.04.5Available from American National Standards Insti

15、tute, 25 W. 43rd St., 4thFloor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.4 Color (see 6.2),5.1.5 Quantity: in pieces, linear feet, or cartons,5.1.6 Height required (see 9.1),5.1.7 Thickness required (see

16、 9.2),5.1.8 Length required (see 9.3, 9.3.1, and Section 15),5.1.9 Lot information, if other than as specified in ANSI/ASQC Z1.41993, (see 11.1 and 13.1),5.1.10 Sampling, if other than as specified in ANSI/ASQCZ1.41993, (see 11.1),5.1.11 Statement requesting certification, if certification ofcomplia

17、nce is required (see Section 14),5.1.12 Packing requirements, if other than as specified (seeSection 16),5.1.13 Palletization, if required,5.1.14 Marking required, if other than specified (see Section15), and5.1.15 Other requirements.6. Materials and Manufacture6.1 MaterialsAny polymeric material or

18、 combination ofpolymeric materials is acceptable if, in combination withprocessing chemicals, fillers, and colorants, the material can beformed into wall base, which satisfies all the requirements ofthis specification (see 5.1 and 7.1). Other suitable recycledpolymeric material may be incorporated a

19、s a part of the totalpolymeric content.6.2 ColorThe color shall be as specified in the contract ororder (see 5.1.4).NOTE 2The colors and styles that are available are indicated inindividual manufacturers current catalogs. As manufactured, colors mayvary somewhat in hue or shade from the catalog.NOTE

20、 3Where color match is a concern, obtain current samples fromthe manufacturer to verify color acceptability.6.2.1 Solid Wall Base The color shall be uniform through-out the entire thickness of the wall base.6.2.2 Layered Wall BaseThe surface color need not ex-tend through the entire thickness of the

21、 wall base, but mustextend throughout the entire wear layer. Layered wall baseshall have a minimum wear layer thickness of 0.002 in. (0.05mm) when measured in accordance with Test Method F 410and shall not delaminate under normal use.6.3 StylesThe style shall be as specified in the contract ororder

22、(see 5.1.2).6.3.1 Straight Wall BaseThe exposed surface of straight(toeless) wall base is vertical, as illustrated by the firstcross-sectional profile in Fig. 1.6.3.2 Cove Wall Base The exposed surface of cove wallbase shall be distinguished by a “toe” at its bottom edge asillustrated by the second

23、cross-sectional profile in Fig. 1.6.3.2.1 Fit to Floor The toe shall be curved, or angled, orboth, to allow it to fit snugly against the floor when the verticalportion of the cove base is adhered to the wall.6.3.2.2 Intersection at ToeThe intersection of the exposedsurfaces of the toe and the vertic

24、al portion of the cove baseshall be rounded and smooth to facilitate maintenance.6.3.3 Butt-to Wall BaseThe exposed surface of butt-toFIG. 1 Typical Profiles of Wall BaseF1861022wall base shall be distinguished by a “toe,” which butts againstthe flooring as illustrated by the third cross-sectional p

25、rofile inFig. 1.6.3.3.1 Fit to Floor The leading edge of the toe of thebutt-to base shall be square to allow a tight, flush fit to thefinished flooring when the vertical portion of the butt-to base isadhered to the wall.6.3.3.2 Intersection at ToeThe intersection of the exposedsurfaces of the toe an

26、d the vertical portion of the butt-to baseshall be designed to facilitate maintenance.7. Material Definitions7.1 The following definitions will be used in classifyingmaterial according to 4.1:7.1.1 Rubber, Vulcanized ThermosetThe polymeric binderof this compound shall satisfy the definition of rubbe

27、r, andhave been vulcanized, as defined in Terminology D 1566.7.1.2 Rubber, ThermoplasticThe polymeric binder of thiscompound shall satisfy the definition of rubber, but remainthermoplastic, as defined in Terminology D 883.7.1.3 Vinyl, ThermoplasticThe polymeric binder of thiscompound shall satisfy t

28、he definition of poly (vinyl chloride) inTerminology D 883 and Specification D 1755 but remainthermoplastic as defined in Terminology D 883.8. Performance Requirements8.1 Flexibility Unless otherwise specified in the contractor order (see 5.1), the wall base shall show no visible cracks,breaks, or o

29、ther evidence of weakness when tested in accor-dance with Test Method F 137 using a14 in. (6.35 mm)diameter mandrel.NOTE 4Cove wall base shall be tested with the mandrel perpendicularto the cove when oriented as in use.8.2 Staining of Adjacent Surfaces Induced by Wall BaseWall base shall contain no

30、ingredient which will cause stainingof the finished surfaces adjacent to it when aged by the methodspecified in 12.1-12.7.8.3 Resistance to LightWhen tested in accordance to TestMethod F 1515, the color change of the wall base shall have anaverage DE no greater than 8.0 after 200 h of exposure to li

31、ght,simulated by a properly fitted xenon-arc radiant energy source.8.4 Resistance to ChemicalsWhen tested in accordancewith Test Method F 925, the wall base shall have no more thana slight change in surface dulling, surface attack, or stainingwhen exposed to the following chemicals:8.4.1 White vineg

32、ar (5 % acetic acid).8.4.2 Rubbing alcohol (70 % isopropyl alcohol).8.4.3 White mineral oil (medicinal grade).8.4.4 Sodium hydroxide solution (5 % NaOH).8.4.5 Hydrochloric acid solution (5 % HCl).8.4.6 Sulfuric acid solution (5 H2SO4).8.4.7 Household ammonia solution (5 % NH4OH).8.4.8 Household blea

33、ch solution (5.25 % NaOCl).8.4.9 Olive oil (light).8.4.10 Kerosene (K1).8.4.11 Unleaded gasoline (regular grade).NOTE 5These basic chemicals are representative of those likely to befound in domestic, commercial, and institutional use. Many proprietarycompounds contain one or more of these basic chem

34、icals. Should the wallbase for an unusual application need to be resistant to a specific chemical,this additional requirement should become part of the procurementdocument.8.5 Dimensional StabilityWall base shall not change inlength by more than 6 0.25 % when tested by the methodspecified in 12.8-12

35、.15.8.6 OdorThe wall base shall be free from offensive odor.9. Dimensions and Permissible Variations9.1 HeightThe height of the wall base shall be as speci-fied in the contract or order (see 5.1.6). A tolerance of 61%ofthe nominal height of the wall base shall be permitted whenmeasured with a scale,

36、 caliper, or other device graduated in0.001in. (0.025 mm) divisions and capable of measuring themaximum height of the specimen. The specimen shall beplaced on a flat surface and the measuring device applied insuch a manner that the height is not distorted during measure-ment.9.2 ThicknessUnless othe

37、rwise specified in the contract ororder (see 5.1.7), the wall base shall be 0.080 in. (2.03 mm) or0.125 in. (3.17 mm) thick. A permissible tolerance for 0.080 in.(2.03 mm) thick wall base shall be +0.015 in. to 0.005 in.(+0.38 mm to 0.13 mm) and 0.125 in. thick wall base shallhave a permissible tole

38、rance of +0.015 in. to 0.015 in. (+0.38mm to 0.38 mm) when measured in accordance with TestMethod F 386.9.3 LengthThe length of the wall base shall be as speci-fied in the contract or order (see 5.1.8). The length of the wallbase shall not be less than as marked on the label or packagewhen measured

39、with a calibrated scale or tape graduated in 1/8in. (3.18 mm) divisions and capable of measuring the maxi-mum length of the specimen. The specimen shall be extendedto its full length on a flat surface and all creases and bucklesremoved, insofar as practical, without applying stresses thatcause any s

40、ignificant stretching. The measuring device shall beapplied in such a manner that the length is not distorted duringmeasurement.9.3.1 If a roll contains multiple lengths, a maximum of threepieces shall be permitted; the shortest length shall not be lessthan 15 ft (4.57 m).9.4 SquarenessEach vertical

41、 end of the wall base shallform an angle of 90 6 0.5 with the top edge and shall fitagainst the vertical end of another length so that a 0.010 in.(0.254 mm) feeler gage cannot be inserted between the sectionsat any point.10. Workmanship, Finish and Appearance10.1 The wall base furnished in accordanc

42、e with this speci-fication shall be free of defects, which adversely affect perfor-mance or appearance. Such defects include blemishes, spots,lines, indentations, blisters, and delamination.10.2 Unless otherwise specified in the contract or order (see5.1), the back or bonding surface of the wall bas

43、e shall bebuffed, roughened, ribbed, grooved, or otherwise modified toimprove the application to and adhesion to the wall surface, butin no case shall the thickness of the wall base be decreased tothe extent that any depression or groove on the bonding surfaceF1861023be perceptible, under any circum

44、stances, on the exposedsurface.11. Sampling for Test11.1 Sampling for testing physical characteristics listed inTable 1 shall be done in accordance with the provisions setforth in ANSI/ASQC Z1.41993. The inspection level shall bespecial inspection level S-1, as noted in Table I of ANSI/ASQCZ1.41993,

45、 and acceptable quality level (AQL) shall be 6.5defects per hundred units as noted in Table II-A of ANSI/ASQC Z1.41993 or as otherwise specified in 11.2. The lotshall be expressed in units. A unit represents a single, manu-factured, inventoried, finished carton or roll.11.2 Sampling for testing phys

46、ical characteristics listed inTable I of ANSI/ASQC Z1.41993 shall be agreed upon by thepurchaser and manufacturer as part of the procurement docu-ment.12. Test MethodsWall BaseStaining of Adjacent Surfaces Induced byWall Base12.1 ScopeThis test method describes a technique forproducing a stain or di

47、scoloration that wall base may causewhen in contact with a light-colored surface, when exposed toelevated temperature aging under controlled conditions.12.2 Significance and UseWall base often is required tobe in contact with light-colored surfaces. In such applications,the discoloration or stain of

48、 the light-colored surfaces isobjectionable. This test method provides a way to evaluate wallbase for its staining characteristics.12.3 Apparatus:12.3.1 Circulating-Air Oven, capable of maintaining a tem-perature of 158 6 1.8F (70 6 1C).12.4 MaterialsMetal panels 2 in. (51 mm) square shall becut fro

49、m No. 20 gage (approximately 0.9 mm) sheet metal thathas been finished with a white acrylic enamel. The panels shallbe aged for at least 48 h, after finishing, before use in this testmethod.12.5 Test Specimen Prepare the test specimens from aproduction part. Cut the specimen in a rectangular shape 1 by0.5 in. (25 by 13 mm). Test the specimen as received. Removeextraneous contamination with a mild soap solution or bymechanical means without abrading the surface of the speci-men.12.6 Procedure:12.6.1 Place two wall base s

展开阅读全文