ASTM F1995-2000(2005) Standard Test Method for Determining the Bond Strength for a Surface Mount Device (SMD) by Applying Shear Force on a Membrane Switch《利用薄膜开关剪切力测定表面安装设备(SMD)粘着强.pdf

上传人:dealItalian200 文档编号:536247 上传时间:2018-12-06 格式:PDF 页数:2 大小:62.78KB
下载 相关 举报
ASTM F1995-2000(2005) Standard Test Method for Determining the Bond Strength for a Surface Mount Device (SMD) by Applying Shear Force on a Membrane Switch《利用薄膜开关剪切力测定表面安装设备(SMD)粘着强.pdf_第1页
第1页 / 共2页
ASTM F1995-2000(2005) Standard Test Method for Determining the Bond Strength for a Surface Mount Device (SMD) by Applying Shear Force on a Membrane Switch《利用薄膜开关剪切力测定表面安装设备(SMD)粘着强.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: F 1995 00 (Reapproved 2005)Standard Test Method forDetermining the Bond Strength of a Surface Mount Device(SMD) on a Membrane Switch by Applying Shear Force1This standard is issued under the fixed designation F 1995; the number immediately following the designation indicates the year of

2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the shearinte

3、grity of materials and procedures used to attach surfacemount devices (SMD) to a membrane switch circuit.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and

4、 health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 membrane switchA momentary switching device inwhich at least one contact is on (or made of) a flexiblesubstrate.2.1.2 shear loadA force applied parallel to the mountingsurfac

5、e sufficient to shear the SMD from its mounting.2.1.3 SMDAbbreviation for surface mount device (that is,light emitting diode (LED), resistor)2.1.4 attachment mediaA mounting adhesive used forelectrical or mechanical bonding, or both, of the SMD to thesubstrate.2.1.5 platingA thin metallic coating (t

6、hat is, gold, nickel)covering the leads of the SMD or circuit, or both, in theelectrical interface area.3. Significance and Use3.1 The different combinations of SMD types, attachmentmedias, circuit substrates, plating options, and process varia-tion can account for significant variation in test outc

7、ome.3.2 The SMD shear strength test is useful to manufacturersand users for determining the bond strength of the componentto the membrane switch circuit.4. Interferences4.1 The following parameters may affect the results of thistest:4.1.1 Temperature and humidity, and4.1.2 Substrate movement during

8、test.5. Apparatus5.1 Device, shall consist of a load-applying instrument withan accuracy of 6 5 % of full scale capable of indicating peakhold.5.2 Mounting Fixture, method to secure specimen to insurestability during test.5.3 SMD Contact Tool, suitable to apply a uniform distri-bution of force to an

9、 edge of the SMD.5.4 Magnification Device, suitable to facilitate visual obser-vation of the SMD and contact tool interface during testing(optional).6. Procedure6.1 Pretest Setup:6.1.1 Attach specimen to the test base to minimize move-ment of the substrate during test. Ensure that no damage occursdu

10、ring attachment to the test base that could affect bondperformance.6.1.2 The direction of applied force shall be parallel with theplane of the circuit substrate.6.1.3 The SMD contact tool shall load against an edge of thecomponent, which most closely approximates a 90 angle withthe base of the circu

11、it substrate. Contact tool should makecontact to SMD at a point equal to or less than12 the total SMDheight, (see Fig. 1).6.2 In-Process Test:6.2.1 Bring contact tool into contact with SMD specimen.6.2.2 Gradually increase force, not to exceed 225 g/s, untilbond failure.6.2.3 After initial contact w

12、ith the SMD edge and during theapplication of force, the relative position of the contact toolshall not move such that contact is made with the circuit planeor SMD attachment media. If the tool rides over the SMD, anew specimen shall be substituted.6.2.4 Record force measured to shear SMD.7. Report7

13、.1 Report the following information:7.1.1 Temperature.7.1.2 Humidity.1This test method is under the jurisdiction of ASTM Committee F01 onElectronics , and is the direct responsibility of Subcommittee F01.18 on MembraneSwitches .Current edition approved May 1, 2005. Published June 2005. Originallyapp

14、roved in 1999. Last previous edition approved in 2000 as F 199500.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.1.3 Shape and size of contact tool.7.1.4 Orientation of SMD to contact tool.7.1.5 SMD information: SMD part number, p

15、lating type,etc.7.1.6 Circuit or substrate type.7.1.7 Attachment media type.7.1.8 Force applied by contact tool when bond failureoccured.7.1.9 SMD size.7.1.10 Type of encapsulent used.8. Precision and Bias8.1 The precision and bias of this test are under investiga-tion.9. Keywords9.1 adhesion; bond

16、strength; LED; membrane switch; shearforce; SMD; surface mountASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such

17、patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited

18、either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fa

19、ir hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).FIG. 1 SMD ContactF 1995 00 (2005)2

展开阅读全文
相关资源
猜你喜欢
  • BS PD ISO TS 11999-2-2015 PPE for firefighters Test methods and requirements for PPE used by firefighters who are at risk of exposure to high levels of heat and or flame while figh.pdf BS PD ISO TS 11999-2-2015 PPE for firefighters Test methods and requirements for PPE used by firefighters who are at risk of exposure to high levels of heat and or flame while figh.pdf
  • BS PD ISO TS 13399-71-2016 Cutting tool data representation and exchange Graphical data layout Creation of documents for standardized data exchange Graphical product information《切削.pdf BS PD ISO TS 13399-71-2016 Cutting tool data representation and exchange Graphical data layout Creation of documents for standardized data exchange Graphical product information《切削.pdf
  • BS PD ISO TS 13399-72-2016 Cutting tool data representation and exchange Creation of documents for the standardized data exchange Definition of properties for drawing header and th.pdf BS PD ISO TS 13399-72-2016 Cutting tool data representation and exchange Creation of documents for the standardized data exchange Definition of properties for drawing header and th.pdf
  • BS PD ISO TS 15926-11-2015 Industrial automation systems and integration Integration of life-cycle data for process plants including oil and gas production facilities Methodology f.pdf BS PD ISO TS 15926-11-2015 Industrial automation systems and integration Integration of life-cycle data for process plants including oil and gas production facilities Methodology f.pdf
  • BS PD ISO TS 16550-2014 Nanotechnologies Determination of silver nanoparticles potency by release of muramic acid from $iS$it$ia$ip$ih$iy$il$io$ic$io$ic$ic$iu$is $ia$iu$ir$ie$iu$is.pdf BS PD ISO TS 16550-2014 Nanotechnologies Determination of silver nanoparticles potency by release of muramic acid from $iS$it$ia$ip$ih$iy$il$io$ic$io$ic$ic$iu$is $ia$iu$ir$ie$iu$is.pdf
  • BS PD ISO TS 17822-1-2014 $iI$in $iv$ii$it$ir$io diagnostic test systems Qualitative nucleic acid-based $ii$in $iv$ii$it$ir$io examination procedures for detection and identificati.pdf BS PD ISO TS 17822-1-2014 $iI$in $iv$ii$it$ir$io diagnostic test systems Qualitative nucleic acid-based $ii$in $iv$ii$it$ir$io examination procedures for detection and identificati.pdf
  • BS PD ISO TS 17865-2016 Geometrical product specifications (GPS) Guidelines for the evaluation of coordinate measuring machine (CMM) test uncertainty for CMMs using single and mult.pdf BS PD ISO TS 17865-2016 Geometrical product specifications (GPS) Guidelines for the evaluation of coordinate measuring machine (CMM) test uncertainty for CMMs using single and mult.pdf
  • BS PD ISO TS 17951-1-2016 Water quality Determination of fluoride using flow analysis (FIA and CFA) Method using flow injection analysis (FIA) and spectrometric detection after off.pdf BS PD ISO TS 17951-1-2016 Water quality Determination of fluoride using flow analysis (FIA and CFA) Method using flow injection analysis (FIA) and spectrometric detection after off.pdf
  • BS PD ISO TS 17951-2-2016 Water quality Determination of fluoride using flow analysis (FIA and CFA) Method using continuous flow analysis (CFA) with automated in-line distillation《.pdf BS PD ISO TS 17951-2-2016 Water quality Determination of fluoride using flow analysis (FIA and CFA) Method using continuous flow analysis (CFA) with automated in-line distillation《.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1